Accuenergy Acuvim 3-M-MV-P1 Offers

The Acuvim 3 advanced power quality meters are engineered to provide high-precision power quality metering plus revenue grade, IEC Class 0.1S/ANSI C12.20 Class 0.1 (active energy) four-quadrant power monitoring. With support for synchrophasor applications, it can record real-time power quality disturbances, like dips, swells interruptions, unbalance, flicker, and transients as well as capture critical waveforms triggered by sub-second power quality events. Its enhanced Fast Log capture feature can generate and send reports, providing critical information to mitigate the impact of damaging power quality issues. Compact and robust, this advanced power quality meter features a wide range of flexible communication protocols plus an easy-to-use interface with advanced user management and security.

Features

  • Advanced single-point metering with revenue grade accuracy
  • Fast Log captures instantaneous power quality events and saves a report for future assessment
  • Reduce downtime and prevent unexpected equipment errors with sophisticated power quality metering with event notification via email, digital output, or relay output
  • Two, powerful HMI options: Easy-to-use 7" (17.78 cm) touchscreen interface or advanced, built-in web interface for real-time analysis on the go
  • Compact design for flexible installation and straightforward system or panel integration
  • Recieve instant email notifications to stay informed of system or equipment failures from anywhere
  • IEC 61000-4-30 Class-A Compliant Metering of Split-Second Power Malfunctions
  • IEC 61557-12 Class 0.1 Accuracy Compliant for Voltage/Current RMS
  • IEC 62053-22 Class 0.1s and ANSI C12.20 Class 0.1 Accuracy for Active Energy
  • IEC 62053-24 Class 0.5s Accuracy for Reactive Energy
  • Multi-protocol support: Modbus-RTU, Modbus-TCP/IP, BACnet-IP, DNP3 TCP, IEC 61850, & SNMP
  • PMU (IEEE C37.118) for fast and reliable synchrophasor measurement
  • Waveform Capture detection up to 512 sample/cycle and stored in COMTRADE format
  • Time of Use (TOU) with eight tariff and up to twelve billing periods
  • Fast Log capture with 1 cycle RMS
  • Up to 100 dataloggers with user-selectable logging interval and parameters
  • Data post: HTTP/HTTPs, SFTP, and email

Power quality metering

IEC 61000-4-30 Class-A compliant measurement for:

  • Voltage/Current RMS, updated at 1 cycle with IEC 61557-12 Class 0.1 accuracy
  • Frequency, 1 mHz accuracy, 40 to 70 Hz
  • Voltage/Current harmonics magnitude and angle, up to 127th
  • Voltage/Current unbalance
  • Flicker

Power quality reporting and analysis

Power quality event detection for:

  • Voltage dip/swell/interruption based on 1 cycle RMS
  • Current dip/swell based on 1 cycle RMS
  • Transient overvoltage based on 32 ksps

Power quality event to trigger email notification, or DO/RO

Up to 65,535 power quality event logs in circular buffer

Waveform Capture

  • Triggered by power quality or manually
  • User configurable sample rate up to 512 sample/cycle
  • User configurable duration (pre-trigger + post-trigger) from two cycles to two seconds at 512 sample/cycle
  • COMTRADE format, download from webpage/SFTP, or post via HTTP(s), FTP, SFTP

Fast Log Capture

  • Triggered by power quality or manually
  • Capture with 1 cycle RMS
  • User configurable duration, same as Waveform Capture
  • Fast log report, download from webpage/SFTP, or post via HTTP(s), FTP, SFTP

Reporting

  • EN50160 compliance report
  • IEEE 519 compliance report
  • ITIC (CBEMA) Curve
  • SEMI-F47 Curve

Advanced power and energy metering

IEC 62053-22 Class 0.1S active energy measurements

IEC 62053-24 Class 0.5S reactive energy measurements

Import/export/net/total and Four-Quadrant energy measurements

Time of Use (TOU) support:

  • Up to eight tariff rates
  • Flexible calendar and billing date configuration
  • Record current and up to twelve historic billing periods

Communication protocols

  • Modbus-RTU via RS485
  • Dual ethernet
  • WiFi
  • Modbus-TCP/IP
  • HTTPs Webserver
  • HTTP/HTTPs Post
  • BACnet-IP
  • FTP Post
  • SMTP
  • SNMP
  • SNTP
  • DNP3 over IP
  • IEC 61850
  • PMU

Applications

  • Power quality
  • Data centers
  • Industrial automation
  • Manufacturing facilities
  • Transportation
  • Utilities
  • Healthcare
  • Telecommunications
  • University laboratories


Accuenergy Acuvim 3-M-MV-P1 Specifications

Specifications

General
Voltage Accuracy0.1% reading, 10 to 400 VLN, 690 VLL
Current Accuracy0.1% reading:1 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 A
Frequency Accuracy1 mHz, 40 to 70 Hz
Active Energy AccuracyIEC 62053-22 Class 0.1SANSI C12.20 Class 0.1
Power QualityIEC 6100-4-30 Class A, testing according to IEC 62586-2 (2017)
SafetyIEC/UL 61010-1:2010IEC/UL 61010-2-030:2010Overvoltage Category IIIMeasurement Category III
Measurements
Voltage RMSIEC 61557-12 Class 0.1, 10 to 400 VLN, 690 VLL
Current RMSIEC 61557-12 Class 0.11 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 A
Frequency1 mHz accuracy, 40 to 70 Hz, exceeds requirement of IEC 61557-12 Class 0.02
Power and Power Factor (for each phase and system)Active power: IEC 61557-12 Class 0.1ReActive power: Exceeds requirement of IEC 61557-12 Class 1Apparent power: IEC 61557-12 Class 0.2Power factor: Exceeds requirement of IEC 61557-12 Class 0.5
Fundamental MeasurementsLine to neutral voltage RMSLine to line voltage RMSLine current RMSActive powerReactive powerApparent powerPower factor
maximumimum/Minimummaximumimum/minimum of RMSPower and power factorsFundamental measurements records with timestamp
DemandAlgorithms: Block and rolling windowLog peak demand and peak demand timeCurrent demand for each phase and systemPer phase and system active power demand:Import/export/net/totalFour-quadrantPer phase and system reactive power demand:Import/export/net/totalFour-quadrantPer phase and system apparent power demand:TotalFour-quadrant
Energy (per phase and system)Active energy, IEC 62053-22 Class 0.1S:Import/export/net/totalFour-quadrantReactive energy, IEC 62053-24 Class 0.5S:Import/export/net/totalFour-quadrantPer phase and systemApparent energy, IEC 61557-12 Class 0.2:TotalFour-quadrant
TOU Energy and DemandFor system import active energy, import reactive energy, and apparent energy:Up to 8 tariff ratesRecord maximumimum power demand of billing periodRecord current and up to 12 historic billing periods
Power Quality MeasurementsPositive/negative/zero sequence for current and voltagePhase angle for current and voltageHarmonics magnitude and angle for current and voltage, up to 127thFlicker
Communications
Communication Interfaces2 x Ethernet ports (100BASE-TX) with IEEE1588 support: RJ45 connector, CAT5/5e/6/6a cable1 Wi-Fi (802.11 b/g/n 2.4 GHz)1 RS485 port: Baud rates of 2400 to 115,200, pluggable screw terminal connector1 USB-C port1 IRIG-B port
Time SynchronizationNTPPTPIRIG-B
Serial Port ProtocolsModbus RTU
Web ServerHTTP/HTTPS
Ethernet Port ProtocolsIPv4, IPv6, DHCP, DNSModbus TCP, DNP3 TCP, IEC 61850, SNMP, BACnet/IP, PMU (IEEE C37.118)Data post with HTTP(s)/FTP/SFTP/SMPT/SMPT E-mailFile download with HTTP(s)/SFPT
Electrical Characteristics
Power Supply50/60 Hz, 100 to 415 V AC/100 to 300 V DC
AC Voltage InputsAccuracy range: 10 to 400 VLN, 690 VLLPickup: 5 VOverload: 1500 V AC continuously; 2500 V AC, 50/60 Hz 1 minuteMeasurement category: IIIFrequency range: 40 to 70 Hz (50/60 Hz nominal)
AC Current InputsNominal current: 1 or 5 AAccuracy range:1 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 APickup:1 A nominal: 0.5 mA5 A nominal: 2.5 mASurge: 20 A continuous, 50 A at 10 second/hour, 500 A at 1 second/hour
Input and Output (meter base)4 digital inputs:Input voltage range: 20 to 150 V AC/DCInput current (maximum): 2.5 mAStart voltage: 15 VStop voltage: 5 VPulse frequency (maximum): 100 Hz, 50% duty ratio (5ms ON and 5ms OFF)SOE resolution: 2ms1 digital output:Dry contactVoltage range: 30 V DCLoad current: 60 mA (maximum)Output frequency: 50 Hz, 50% duty ratio (20ms ON, 20ms OFF)Isolation voltage: 5000 V AC
I/O Modules (up to 3, sold separately)Digital input:Input voltage range 20 to 160 V AC/DCInput current (maximum) 2 mAStart voltage 15 VStop voltage 5 VPulse frequency (maximum) 100 Hz, 50% duty ratioSOE resolution 2msDigital output (DO) (Photo-MOS):Voltage range 0 to 250 V AC/DCLoad current 100 mA(maximum)Output frequency 25 Hz, 50% duty ratioIsolation voltage 2500 V ACRelay output (RO):Switching voltage (maximum) 250 V AC, 30 V DCLoad current 5 A(R), 2 A(L)Set time 10ms (maximum)Contact resistance 30 mΩ (maximum)Isolation voltage 2500 V ACAnalog output (AO):Output range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional)Accuracy 0.5%Temperature drift 50 ppm/°C typicalIsolation voltage 500 V DCOpen circuit voltage 15 VAnalog input (AI):Input range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional)Accuracy 0.2%Temperature drift 50 ppm/°C typicalIsolation voltage 500 V DC
Mechanical Characteristics
Outlines StandardDIN 43700, ANSI C39.1Round or square, 3.6 x 3.6" (92 x 92 mm)
IP Degree of ProtectionIP 54: panel mount and touchscreen display, frontIP 30: panel mount rear, DIN rail mount, I/O modules
Environmental Conditions
TemperatureOperating: -13 to 158°F (-25 to 70°C)Storage: -40 to 158°F (-40 to 70°C)
PressureNormal
Humidity5 to 95% RH non-condensing
Altitude9842.5' (3000 m)
Pollution Degree2
Location/MountingIndoor use only
Electromagnetic Compatibility
Immunity to Fast TransientsIEC 61000-4-4:Power, input/output, voltage/current circuits: ±4 kV (5 kHz)Communication: ±4 kV (5 kHz)
Immunity to Ring WavesIEC 61000-4-12:Power, input/output, voltage/current circuits: 2.5 kVCommunication: 2.5 kV
Immunity to Electrostatic DischargeIEC 61000-4-2:Contact discharge: ±4 kVAir discharge: ±8 kV
Immunity to Voltage Dips and InterruptionsIEC 61000-4-11:70%, 20 ms0%, 100 ms
Immunity to Power Frequency and Magnetic FieldsIEC 61000-4-8:100 A/m, 1 minute1000 A/m, 3 seconds
Immunity to SurgesIEC 61000-4-5:Power, voltage/current circuits: ±4 kVInput/output: 2 kVCommunication: 2 kV
Immunity to Radiated FieldsIEC 61000-4-3:80 to 1000 MHz: 10 V/m1 to 2.7 GHz: 3 V/m2.7 to 6.0 GHz: 1 V/m
Immunity to Conducted DisturbancesIEC 61000-4-6:150 kHz to 80 MHz: 10 V
Immunity to Power Frequency DisturbancesIEC 61000-4-16:30 V: 1 minute300 V: 1 s
Immunity to Damped Oscillatory WaveIEC 61000-4-18:AC:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)1 kV (differential mode, 10 MHz)DC:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)1 kV (differential mode, 10 MHz)IO:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)
Radiated EmissionsCISPR 32 Class B


What's included with the Accuenergy Acuvim 3-M-MV-P1
  • Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 333 mV, AC/DC


Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 333 mV, AC/DC. Great savings PLUS Free Shipping when you buy now from EquipTestPro.com.
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns