null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

AEMC 606 Clamp-On Meter, 2000 A AC/3000 A DC, energy/power/THD

No reviews yet Write a Review
$590.52
SKU:
606
Availability:
2 to 3 Weeks
5 customers are viewing this product

AEMC 606 Clamp-On Meter, 2000 A AC/3000 A DC, energy/power/THD

$590.52

Availability: 2 to 3 Weeks

AEMC Instruments 606 Offers

Work with a boost in AC and DC voltage with this meter, offering enhanced functionality for solar/photovoltaic (PV) purposes. In addition, this meter features a large 10,000-count blue electroluminescent backlit display.

Features

  • Large 10,000-count blue electroluminescent backlit display
  • Measures W, VA, var and PF for single- and three phase balanced systems
  • Phase rotation order indication
  • Auto selects AC or DC measurement voltage
  • Current measurement
  • Measurement of Inrush current/overcurrent (True InRush®)
  • Voltage measurement
  • Frequency measurement
  • Measures harmonic distortion (THD)
  • Continuity test with buzzer
  • Resistance measurement
  • Diode test
  • Power measurements (W, VA, var and PF)
  • Phase order indication
  • Jaw opening up to 2.36" (60 mm) with centering marks
  • Physical guard
  • Rotary switch
  • Function buttons
  • Input terminals
  • Trigger
  • Battery compartment and compartment screw
  • Power measurements: Available for watts, VARs and VA, including minimum and maximum tracking and has the unique capability to display single and three phase power measurements
  • 1700 V DC/1200 V AC measurements
  • 1000 V CAT IV/1500 V CAT III safety rated
  • UL94 V1 flame retardant self-extinguishing
  • IP54: This meter is rugged enough for the most demanding work environments and will withstand both dust and water spray, guaranteeing its safety level over time
  • THD-r/THD-f
  • Phase rotation
  • Auto power OFF
  • Hold button
  • Backlight button
  • Min/Max button
  • Relative function
  • Peak ± function
  • Hz button

A range offering unprecedented analytical and diagnostic functions!

TRMS version of Min and Max: The Min and Max are TRMS values calculated over a duration of up to 100 ms. This feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc.

Peak+ and Peak-: Calculated over a period of 1 ms, the Peak+ and Peak- values help to characterize the distortion affecting the signal measured. For example, they may reveal variations in the installation's behavior or even malfunctions.

ΔREL, for quick evaluation: Comparison with a reference quantity is a quick way of evaluating and analyzing your results. A signal's variations can be measured differentially or relatively. The first method indicates the difference between the value of reference and the value measured. The second method indicates the proportion. The ΔRELfunction can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions

Feature rich clamp-on meter

Ideal tool for any work in the field and is simple to use and groups all the necessary functions in a single, compact solution. Leveraging cutting-edge technology, this meter guarantees top-notch quality while ensuring user-friendly simplicity.

Performance

Benefit from a fast 12-bit TRMS digital acquisition system offering high measurement accuracy. Thanks to it's large bandwidth and high crest factor, this clamp provides accurate measurements whatever the signal type.

Ergonomics

The entire range is designed for one-handed use, even when wearing safety gloves. For maximum efficiency, each measurement corresponds to a specific switch position. The one key, one function concept makes it even easier to use. In addition, this clamp is equipped with automatic detection of the type of signal (AC or DC) on currents, voltages, and power values.

True InRush® function

True InRush® function provides the unique ability to measure power-up events from devices on a network that is already energized. Unlike other instruments which only measure the inrush when the installation is first powered up, our power clamp-on meters measure all types of inrush, even those due to load increases on an installation which is already up and running.

Applications

  • Photovoltaic (PV)
  • Solar panel, inverter testing, comissioning, engineers, and technicians
  • Solar comissioning
  • High power low voltage locations
  • AC or DC motor testing
  • Electrical power distribution, contractors, and maintenance
  • Commercial, industrial, residential and HVAC/R troubleshooting
  • Safety lighting system maintenance
  • Automotive test troubleshooting
  • Hospitals
  • Field service agencies and technicians
  • Government agencies
  • Educational institutions
  • Plant maintenance personnel
  • Electric utility power quality engineers
  • Data logging
  • Power values (W, var, VA, PF) and harmonics (THDf, THDr)


AEMC Instruments 606 Specifications

Specifications

DC Voltage MeasurementMeasurement range: 0 to 99.99 VSpecified measurement range: 0 to 1600 VAccuracy: 0 to 9.99 V ± (1% R + 10 cts)/10 to 99.99 V ± (1% R + 3 cts)Resolution: 0.01 VInput impedance: 10 MΩMeasurement range: 100 to 999.9 VSpecified measurement range: 0 to 1600 VResolution: 0.1 VInput impedance: 10 MΩMeasurement range: 1000 to 1700 V1)Specified measurement range: 0 to 1600 VResolution: 1 VInput impedance: 10 MΩ1)The display indicates +OL above 3400 V and -OL below - 3400 V, in REL mode. Above 1700 V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed.*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
AC Voltage MeasurementMeasurement range: 0.15 to 99.99 VSpecified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: 0.15 to 9.99 V ± (1% r + 10 cts)/10 to 99.99 V ± (1% R + 3cts)Resolution: 0.01 VInput impedance: 10 MΩ100 to 999.9 VSpecified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: ± (1% R + 4 cts)Resolution 0.1 VInput impedance: 10 MΩMeasurement range: 1000 to 1200 V RMS/1700 V peak1)Specified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: ± (1% R + 4 cts)Resolution 1 VInput impedance: 10 MΩ1)The display indicates OL above 1700 V (in PEAK mode). Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. Bandwidth in AC = 3 kHz2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display.*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
AC+DC Voltage MeasurementMeasurement range: 0.15 to 99.99 VSpecified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: 0.15 to 9.99 v ± (1% r + 10 cts)/10 to 99.99 V ± (1% R + 3cts)Resolution: 0.01 VInput impedance: 10 MΩ100 to 999.9 VSpecified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: ± (1% R + 4 cts)Resolution 0.1 VInput impedance: 10 MΩMeasurement range: 1000 to 1200 V RMS/1700 V peak1)Specified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: ± (1% R + 4 cts)Resolution 1 VInput impedance: 10 MΩMAX/MIN mode in voltage (from 10 Hz to 1 kHz in AC and AC+DC, and from 0.3 V):Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 msPEAK mode in voltage (from 10 Hz to 1 kHz in AC and AC+DC): Accuracy: add 1.5% R to the values abovePEAK capture time: 1 ms minimum to 1.5 ms maximum1)The display indicates OL above 1700 V (in PEAK mode). Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. Bandwidth in AC = 3 kHz2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display.*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
DC Current MeasurementMeasurement range2): 0 to 99.99 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy (zero corrected)2): ± (1% R + 10 cts)Resolution: 0.01 AMeasurement range: 100 to 999.9 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy (zero corrected)2): (1% R + 3 cts)Resolution: 0.1 AMeasurement range: 1000 to 3000 A1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy (zero corrected)2):2000 A ± (1.5% R + 3 cts)2000 to 2500 A ± (2.5% R + 3 cts)2500 to 3000 A ± (3.5% R + 3 cts)Resolution: 1 A1)The display indicates OL above 6000 A and -OL below -6000 A in REL mode. The - and + signs are displayed (polarity)2)The residual current at zero depends on the remanence. It can be corrected by the DC zero function of the HOLD button
AC Current MeasurementMeasurement range2): 0.25 to 99.99 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.01 AMeasurement range2): 100 to 999.9 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 3 cts)Resolution: 0.1 AMeasurement range2): 1000 to 2000 A1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1.5% R + 3 cts)Resolution: 1 A1)The display indicates OL above 3000 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 1 kHz2)In AC, any value between zero and the min threshold of the measurement range (0.25 A) is forced to ---- on the display
AC+DC Intensity MeasurementMeasurement range2): 0.25 to 99.99 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.01 AMeasurement range2): 100 to 999.9 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 3 cts)Resolution: 0.1 AMeasurement range2):AC: 1000 to 2000DC or PEAK: 1000 to 3000 A1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy:Up to 2000 A ± (1.5% R + 3 cts)From 2000 to 2500 A DC ± (2.5% R + 3 cts)From 2500 to 3000 A DC ± (3.5% R + 3 cts)Resolution: 1 AMAX/MIN mode in current (from 10 Hz to 1 kHz in AC and AC+DC, and from 0.30 A):Accuracy (zero corrected): Add 1% R to the values aboveCapture time of the extrema: Approximately 100 msPEAK mode in current (from 10 Hz to 1 kHz in AC and AC+DC):Accuracy: Add ± (1.5% R + 0.5 A) to the values abovePEAK capture time: 1 ms minimum to 1.5 ms maximum1)In DC, the display indicates +OL above +6000 A and -OL above -6000 A in REL mode. The + and - signs are displayed. In AC and AC+DC, the display indicates +OL above 3000 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 1 kHz2)In AC, any value between zero and the min threshold of the measurement range (0.25 A) is forced to ---- on the display
True InRush MeasurementMeasurement range: 20 A to 2000 A AC/20 A to 3000 A DCSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (5% R + 5 cts)Resolution: 1 APeak mode:Accuracy: Add ± (1.5 % R + 0.5 A) to the values abovePeak capture time: 1 ms minimum to 1.5 ms maximum
Continuity MeasurementMeasurement range: 0 to 999.9 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 550 μAAccuracy: ± (1% R + 5 cts)Buzzer triggering threshold: Adjustable from (1 to 999) Ω (40 Ω is the default)
Resistance MeasurementMeasurement range1): 0 to 99.9 ΩSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.1 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 550 μAMeasurement range1): 100 to 999.9 ΩSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (1% R + 5 cts)Resolution: 0.1 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 500 μAMeasurement range1): 10 to 9999 kΩSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 5 cts)Resolution: 1 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 100 μAMeasurement range1): 10 to 99.99 kΩSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 5 cts)Resolution: 10 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 10 μAMAX/MIN mode:Accuracy: add 1% R to the values aboveCapture of the extreme: Approximately 100 ms1)Above the maximum display value, the display unit indicates OL. The - and + signs are not displayed.
Diode TestMeasurement range: 0 to 3.199 V DCSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.001 VMeasurement current: 0.55 mAIndication (junction reversed or open circuit): OL is displayed when the measured voltage >3.199 V
Active DC Power MeasurementsMeasurement range2): 0 to 9.999 kWSpecified measurement range: 1 to 100% of the measurement rangeAccuracy3):Up to 1000 A ± (2% R + 10 cts)1000 to 2000 A ± (2.5% R + 10 cts)2000 to 2500 A DC ± (3.5% R + 10 cts)2500 to 3000 A DC ± (4.5% R + 10 cts)Resolution: 1 WMeasurement range2): 10 to 99.99 kWSpecified measurement range: 0 to 4800 kWAccuracy3):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 10 WMeasurement range2): 100 to 999.9 kWSpecified measurement range: 0 to 4800 kWAccuracy3):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 100 WMeasurement range2): 1000 to 5100 kW1)Specified measurement range: 0 to 4800 kWAccuracy3):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 1000 W1)Display of OL or ± OL above ±5100 kW, in REL mode2)Any applied voltage greater than 1700 V causes the emission of an intermittent alarm beep to report a dangerous overload3)The measurement result may be affected by an instability linked to the current measurement (approximately 0.1 A). Example: For a power measurement made at 10 A, the instability of the measurement will be 0.1 A/10 A or 1%
Active AC Power MeasurementsMeasurement range2)4): 5 to 9.999 kWSpecified measurement range: 1 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 10 cts)1000 to 2000 A ± (2.5% R + 10 cts)Resolution: 1 WMeasurement range2)4): 10 to 99.99 kWSpecified measurement range: 0 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)Resolution: 10 WMeasurement range2)4): 100 to 999.9 kWSpecified measurement range: 0 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)Resolution: 100 Wbr>Measurement range2)4): 1000 to 2400 kW1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)Resolution: 1000 W1)Bandwidth in AC: In voltage = 3 kHz, in current = 1 kHz2)And (3) of the previous § apply4)Any power measured less than 5 W causes the display of dashes. If the voltage is less than 0.15 V or if the current is less than 0.15 A, causes the display of dashes ----7) In balanced three-phases, with deformed signals (THD and harmonics), accuracies are guaranteed since Φ <30°. Additional errors are following, depending of THD: Add + 1% for 10% < THD <20%, add + 3% for 20% < THD <30%, add + 5% for 30% < THD <40%
Active AC+DC Power MeasurementsMeasurement range2)4): 5 to 9.999 kWSpecified measurement range: 1 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 10 cts)1000 to 2000 A ± (2.5% R + 10 cts)2000 to 2500 A DC ± (3.5% R + 10 cts)2500 to 3000 A DC ± (4.5% R + 10 cts)Resolution: 1 WMeasurement range2)4): 10 to 99.99 kWSpecified measurement range: 0 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 10 WMeasurement range2)4): 100 to 999.9 kWSpecified measurement range: 0 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 100 WMeasurement range2)4): 1000 to 5100 kW1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy3)7):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 1000 W1)Bandwidth in AC: In voltage = 3 kHz, in current = 1 kHz2)(3), (4), 5, 6 and (7) of the previous § apply
Measurement of Apparent AC PowerMeasurement range2)4): 5 to 9.999 kVASpecified measurement range: 1 to 100% of the measurement rangeAccuracy3):Up to 1000 A ± (2% R + 10 cts)1000 to 2000 A ± (2.5% R + 10 cts)Resolution: 1 VAMeasurement range2)4): 10 to 99.99 kVASpecified measurement range: 0 to 2200 kVAAccuracy3):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)Resolution: 10 VAMeasurement range2)4): 100 to 999.9 kVASpecified measurement range: 0 to 2200 kVAAccuracy3):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)Resolution: 100 VAMeasurement range2)4): 1000 to 2400 kVA1)Specified measurement range: 0 to 2200 kVAAccuracy3):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)Resolution: 1000 VA1)Bandwidth in AC: In voltage = 3 kHz, in current = 1 kHz2)(3) and (4) of the previous § apply
Measurement of Apparent AC+DC PowerMeasurement range2)4): 5 to 9.999 kVASpecified measurement range: 1 to 100% of the measurement rangeAccuracy3):Up to 1000 A ± (2% R + 10 cts)1000 to 2000 A ± (2.5% R + 10 cts)2000 to 2500 A DC ± (3.5% R + 10 cts)2500 to 3000 A DC ± (4.5% R + 10 cts)Resolution: 1 VAMeasurement range2)4): 10 to 99.99 kVASpecified measurement range: 0 to 100% of the measurement rangeAccuracy3):Up to 1000 A ± (2% R + 3 cts)1000 to 2000 A ± (2.5% R + 3 cts)2000 to 2500 A DC ± (3.5% R + 3 cts)2500 to 3000 A DC ± (4.5% R + 3 cts)Resolution: 10 VAMeasurement range2)4): 100 to 999.9 kVASpecified measurement range: 0 to 100% of the measurement rangeAccuracy3):Up to 1000 A ± (2% R + 3 cts)1000 to 2000 A ± (2.5% R + 3 cts)2000 to 2500 A DC ± (3.5% R + 3 cts)2500 to 3000 A DC ± (4.5% R + 3 cts)Resolution: 100 VAMeasurement range2)4): 1000 to 5100 kVA1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy3):Up to 1000 A ± (2% R + 3 cts)1000 to 2000 A ± (2.5% R + 3 cts)2000 to 2500 A DC ± (3.5% R + 3 cts)2500 to 3000 A DC ± (4.5% R + 3 cts)Resolution: 1000 VA1)Display of O.L above 5100 kVA in single-phase (1700 V x 3000 A). Bandwidth in AC: In voltage = 3 kHz, in current = 1 kHz2)(3) and (4) of the previous § apply
Measurement of Reactive AC PowerMeasurement range2)4): 5 to 9.999 kvarSpecified measurement range: 1 to 100% of the measurement rangeAccuracy3)8):Up to 1000 A ± (2% R + 10 cts)From 1000 to 2000 A ± (2.5% R + 10 cts)Resolution: 1 varMeasurement range2)4): 10 to 99.99 kvarSpecified measurement range: 0 to 2200 kvarAccuracy3)8): Up to 1000 A ± (2% L + 4 cts)From 1000 to 2000 A ± (2.5% L + 4 cts)Resolution: 10 varMeasurement range2)4): 100 to 999.9 kvarSpecified measurement range: 0 to 2200 kvarAccuracy3)8): Up to 1000 A ± (2% L + 4 cts)From 1000 to 2000 A ± (2.5% L + 4 cts)Resolution: 100 varMeasurement range2)4): 1000 to 2400 kvar1)Specified measurement range: 0 to 2200 kvarAccuracy3)8): Up to 1000 A ± (2% L + 4 cts)From 1000 to 2000 A ± (2.5% L + 4 cts)Resolution: 1 kvar1)Bandwidth in AC: In voltage = 3 kHz, in current = 1 kHz2)(3) and (4) of the previous § apply8)In single-phase, with deformed signals (THD and harmonics), accuracies are guaranteed since Φ >30°. Additional errors are following, depending of THD: Add + 1% for 10% < THD <20 %, add + 3% for 20% < THD <30%, add + 5% for 30% < THD <40%
Measurement of Reactive AC+DC PowerMeasurement range2)4): 5 to 9.999 kvarSpecified measurement range: 1 to 100% of the measurement rangeAccuracy3)8):Up to 1000 A ± (2% R + 10 cts)1000 to 2000 A ± (2.5% R + 10 cts)2000 to 2500 A DC ± (3.5% R + 10 cts)2500 to 3000 A DC ± (4.5% R + 10 cts)Resolution: 1 varMeasurement range2)4): 10 to 99.99 kvarSpecified measurement range: 0 to 100% of the measurement rangeAccuracy3)8):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 10 varMeasurement range2)4): 100 to 999.9 kvarSpecified measurement range: 0 to 100% of the measurement rangeAccuracy3)8):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 100 varMeasurement range2)4): 1000 to 5100 kvar1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy3)8):Up to 1000 A ± (2% R + 4 cts)1000 to 2000 A ± (2.5% R + 4 cts)2000 to 2500 A DC ± (3.5% R + 4 cts)2500 to 3000 A DC ± (4.5% R + 4 cts)Resolution: 1 kvarMAX/MIN mode in power (from 10 Hz to 1 kHz):Accuracy: Add 1% R to the values aboveCapture time: Approximately 100 ms1)Display of O.L above 5100 kvar in single-phase (1700 V x 3000 A). Bandwidth in AC: In voltage = 3 kHz, in current = 1 kHz2)(3), (4), 5, 6 and (8) of the previous § apply
Calculation of the Power FactorMeasurement range1): -1 to 1Specified measurement range: 0 to 50% of the measurement range/50 to 100% of the measurement rangeAccuracy7): ± (3% R + 3 cts)/± (2% R + 3 cts)Resolution: 0.01MAX/MIN mode (from 10 Hz to 1 kHz):Accuracy: Add 1% R to the values aboveCapture time: Approximately 100 ms1)If one of the terms in the calculation of the power factor is displayed as O.L, or forced to zero, the display of the power factor is an indeterminate value ----7)Of the previous § applies
Voltage Frequency MeasurementMeasurement range1): 5 to 99.9 HzSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (0.4% R + 1 ct)Resolution: 0.1 HzMeasurement range1): 1000 to 9999 HzSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (0.4% R + 1 ct)Resolution: 1 HzMeasurement range1): 10 to 19.99 kHzSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (0.4% R + 1 ct)Resolution: 10 HzMAX/MIN mode (from 10 Hz to 1 kHz in voltage and from 10 Hz to 1 kHz in current):Accuracy: Add 1% R to the values of the table aboveCapture time of the extrema: Approximately 100 ms1)If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays dashes ----
Current Frequency MeasurementMeasurement range1): 5 to 999.9 HzSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (0.4% R + 1 ct)Resolution: 0.1 HzMAX/MIN mode (from 10 Hz to 1 kHz in voltage and from 10 Hz to 1 kHz in current):Accuracy: Add 1% R to the values of the table aboveCapture time of the extrema: Approximately 100 ms1)If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays dashes ----
THDr and THDfMeasurement range: 0 to 100%Specified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (5% R + 2 cts) in voltage and ± (5% R + 5 cts) in currentResolution: 0.1%MAX/MIN mode in THD (from 10 Hz to 1 kHz):Accuracy: Add 1% R to the values aboveCapture time of the extrema: Approximately 100 msNOTE: The display is if the input signal is too low (V < 8 V or I < 9 A) or if the frequency is less than 5 Hz
Indication of Order of the PhasesFrequency range: 47 to 400 HzAcceptable voltage range: 50 to 1200 VAcquisition duration period: ≤500 msValidity duration period:Approximately 10 s to 50 HzApproximately 2 s to 400 HzAcquisition duration measurement period: ≤500 msAcceptable phase unbalance: ±10°Acceptable amplitude unbalance: 20%Acceptable level of harmonics in voltage: 10%
ScreenLCD unitBlue backlighting
TemperatureOperating: -4 to 131°F (-20 to 55°C)Storage: -40 to 158°F (-40 to 70°C)
Relative Humidity (RH)Operating: ≤90% to 131°F (≤90% to 55°C)Storage: ≤90% to 158°F (≤90% to 70°C)
Power SupplyBatteries: 4 x 1.5 V AA LR6Battery life: >350 hours (without backlighting)Auto power off: After 10 minutes with no switch and/or button activity
Compliance with International StandardsElectric safety: Compliant with standards IEC/EN 61010-1 or BS EN 61010-1, IEC/EN 61010-2-032 or BS EN 61010-2-032: 1000 V CAT IV and 1500 V CAT IIIElectromagnetic compatibility: Compliant with standard EN-61326-1 or BS EN 61326-1, classification: residential environmentMechanical strength:Free fall: 6.6' (2 m) (in accordance with standard IEC-68-2-32)Level of protection:Housing: IP54 (per standard IEC-60529)Jaws: IP40
HousingRigid polycarbonate shell with over-molded elastomer covering; UL94 V1
JawsPolycarbonateOpening 2.4" (60 mm)Clamping diameter: 2.4" (60 mm)
Dimensions11.7 x 4.4 x 1.6" (296 x 111 x 41 mm)Screen: 1.6 x 1.9" (41 x 48 mm)
Weight1.41 lbs (640 g) with the batteries


What's included with the AEMC Instruments 606
  • Clamp-On Meter
  • 2 x Set of Color-Coded Silicone Insulated Test Leads
  • Test Probes
  • Alligator Clips
  • Soft Carrying Case
  • 4 x 1.5 V AA Batteries
  • User Manual
  • Limited Three-Year Warranty


AEMC 606 Clamp-On Meter, 2000 A AC/3000 A DC, energy/power/THD. Great savings PLUS Free Shipping when you order today on EquipTestPro.com.
Shipping & Return Policy — EquipTestPro
Last Updated: February 1, 2026
Legal Policies

Shipping & Return Policy

Everything you need to know about orders, cancellations, refunds, and delivery.

🌎
Section 01
Shipping Destinations

EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.

Please Note: Certain products are subject to restrictions and cannot be shipped to all destinations. Product-specific shipping availability is noted on each item's detail page. We do not currently ship to international destinations outside of Canada and the United States.
💲
Section 02
Shipping Rates

When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.

Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.

⚖️
Section 03
Weight-Based Shipping

For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.

Rounding Policy: To align with the policies of our shipping carriers, all item weights are rounded up to the next full pound when calculating shipping costs.

For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.

⚠️
Section 04
Product Restrictions

Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:

  • Hazardous or regulated materials
  • Oversized or freight-class items
  • Products restricted by provincial or state import regulations
  • Items that cannot be air-shipped due to their composition

Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.

🕐
Section 05
Order Processing

Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.

1
Order Confirmed You receive an email confirmation with your order details.
2
Order Processed Your order is verified and prepared for shipment (1–2 business days).
3
Shipped You receive a tracking number by email once your package is dispatched.
4
Delivered Delivery timelines vary by destination and carrier availability.
Section 01
Order Cancellation Rights

You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.

The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.

To exercise your cancellation right, notify us with a clear written statement by:

  • Email: info@equiptestpro.com
  • Online form: equiptestpro.com/contact-us
💳
Section 02
Cancellation Processing Fees

The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.

Customer-Initiated
10%

A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.

Company-Initiated (Item Unavailable)
$0

If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.

Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.

Section 03
Conditions for Returns

To be eligible for a return, all of the following conditions must be met:

  • The Goods were purchased within the last 30 days
  • The Goods are in their original, undamaged packaging
  • The Goods are unused and unaltered from the condition received
  • A valid receipt or proof of purchase accompanies the return
Sale Items: Only regular-priced Goods are eligible for a refund. Items purchased on sale or at a discounted price cannot be refunded. This exclusion may not apply where prohibited by applicable law.

We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.

🚫
Section 04
Non-Returnable Goods

The following items are not eligible for return under any circumstances:

  • Goods made to your specifications or clearly personalized
  • Goods that by their nature are not suitable for return, deteriorate rapidly, or where the expiry date has passed
  • Goods not suitable for return due to health protection or hygiene reasons that have been unsealed after delivery
  • Goods that, after delivery, have become inseparably mixed with other items by their nature
  • Goods purchased on sale or at a promotional discount
📬
Section 05
How to Return Goods

You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.

Important: We strongly recommend using an insured and trackable mail service. We cannot be held responsible for Goods damaged or lost during return shipment, and we are unable to issue a refund without confirmed receipt of the returned Goods or verifiable proof of delivery.
Section 06
Refund Timeline

You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:

1
Transit to Us 5 to 10 business days for us to receive your return from the shipper.
2
Return Processing 3 to 5 business days to inspect and process your return once received.
3
Bank Processing 5 to 10 business days for your bank to post the refund to your account.

We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.

🎁
Section 07
Gift Returns

If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.

If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.

Questions? We're here to help.

Reach out to our support team for assistance with any order or return.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns