Operate this accurate digital pressure gauge for up to 1500 hours of continuous use with it's 3 x batteries that come included. In addition, this pressure gauge's case is constructed from rugged aluminum alloy that utilizes a gasket to seal the enclosure against dust and water intrusion.
Features
*From the factory this setting is disabled. Use ConfigXP to enable.
Would you know if your gauge was broken?
Some sensors and bourdon gauges read incorrectly after deforming under pressure. You would never know your gauge is broken until you compare it to a reference.
This digital pressure gauge's silicon sensors shatter at very high pressure, but never deform. They always return to their original shape and accuracy, even after accidental overpressure. Sensor self-diagnostics will not allow operation if the sensor is damaged.
Now record up to 32,000 data points
When you purchase DataLoggerXP (sold separately), you transform your digital pressure gauge into a portable pressure data logger. Leave your digital pressure gauge on location as it records and timestamps readings for months at a time. Start and stop recording with a single button, record multiple data sets, or take individual readings. This digital pressure gauge logs pressure at intervals down to 1 reading per second in a number of ways such as Actual Pressure, Average Pressure, or Average Pressure with Peak Hi and Low values.
The DataLoggerXP (sold separately) saves you time!
Pressure safety valve test
No more guess work. Simply enable this feature to increase your read rate to 8 times per second. This digital pressure gauge captures and displays the relief pressure even if you're not looking at the gauge when the valve opens.
You can read this display anywhere
Special features that require the free ConfigXP software
Ultra Low Power (ULP) mode
This digital pressure gauge can log for extended periods with Ultra Low Power Mode, activated by the key combinations. Ultra Low Power mode takes readings in Actual Mode, according to the set logging interval. The letters ULP replace the live pressure reading during a recording. You must stop the recording to view the live pressure. To begin or end a recording hold down the (units) button.
Note: To maximize battery life and recording time in ULP Mode, limit your use of the backlight.
Reset or battery change
Data collected by this digital pressure gauge will not be lost with a gauge reset or battery change, although any run in progress will be stopped. A reset or battery change will affect the operation of the gauge's real-time clock. When this digital pressure gauge is connected to DataLoggerXP (sold separately) and the logging parameters are set, DataLoggerXP (sold separately) also sets the gauge's real-time clock. However, if the gauge resets, or if the batteries are changed or become momentarily disconnected (if the gauge is dropped to the floor, for instance), the real-time clock may be reset. When this occurs, the time stamps of subsequently logged data will no longer be correct. DataLoggerXP (sold separately) reacts to this by attempting to resynchronize the gauge's clock with the computer's clock which will allow the time stamps to be correctly read. However, if multiple resets have occurred with the gauge, only time stamps after the last reset will be fixed. When a reset occurs, it is stored as a run with a reset event and no data.
Resetting (clearing) recorded peak values
Peak values can only be cleared when displaying either a Peak High or Peak Low recorded pressure. Press the (clear) button for at least half a second. Dashed lines will briefly appear across the display indicating that both Peak values have been cleared. Both Peak High and Peak Low values will then display the current applied pressure. Pressing the (clear) button while either the Peak High (HI) or Peak Low (LO) icon is displayed will not affect the zero value. If you need to rezero the gauge, you must turn off both peak icons by pressing the (peak) button.
Automatic shut-off
This digital pressure gauge has a shutoff timer and will turn off automatically after 20 minutes of non-operation. Pressing any button or sending any command via the RS-232 connection resets the shutoff timer for another 20 minutes of operation. This digital pressure gauge display "Auto Off 20" when turned on. To disable the shutoff feature, turn on this digital pressure gauge by pressing the (on/off) and (zero) buttons simultaneously. This digital pressure gauge will briefly display the words No Auto Off to indicate that it will not turn off. The shutoff feature can be enabled again when turning this digital pressure gauge on, by pressing the same (on/off) and (zero) buttons. These settings are retained when the product is powered down. Note: This key combination will not toggle the auto-shutoff feature if ConfigXP is set to require a password before changing settings.
Low battery indicator
The battery icon uses three bars to display the battery level. When the icon displays all three bars, the batteries are full. This digital pressure gauge will continue to operate accurately while the icon is visible. When the batteries are exhausted, the letters "batt" will appear across the display. After "batt" appears, no pressure measurements will be possible until the batteries are replaced.
DataLoggerXP (sold separately) is ideal for:
Applications
Keeping track of the calibration intervals for all test equipment can be a challenging task in which human error can occur. Calibration stickers or certificates can be misplaced or lost, or the technician may not notice that the gauge is beyond its calibration dates. Even if a company has a system to keep track of these dates, it still requires somebody to notify the technician when re-calibrations are due. It also requires the technician to remove the gauge from service once they are notified. In some industries, auditing of test equipment may result in significant fines if it's found that a gauge was used beyond its calibration due date.
Never miss a calibration again with this digital pressure gauge
Multiple options available
Reminders:
Due alerts:
Consistent performance in the coldest places on earth (northern Canada)
In northern Canada, our customers perform hydrostatic testing during winter, when pipelines become accessible by snowcat. They count on this digital pressure gauge to be accurate and ready for work when they get there.
This digital pressure gauge proves itself (middle east)
Oil workers on middle east pipelines operate every day in the blowing sand, under the hot desert sun. They need a reliable, Intrinsically Safe pressure gauge that works as hard as they do. From pressure testing and equipment calibration to long-term recording, they choose this digital pressure gauge.
For calibration technicians with no time to waste nuclear power
Nuclear power technicians have limited time for testing, and no time for mistakes. They need an accurate, simple measuring tool that can be configured to specific tasks. This digital pressure gauge is trusted in more nuclear power stations than any other similar product.
When the right tool matters (north sea)
Equipment on north sea platforms must endure harsh conditions. Not only do their gauges have to withstand extreme weather and saltwater spraythey have to be accurate. This digital pressure gauge is the obvious choice.
Range | 1 Kpsi |
Over-Pressure | 2.0 x |
Display | Screen: 5.5 digits Single line display: 0.67" (16.9 mm) high Rate: 4 readings/second (standard) and 8 readings/second (PSV mode) LCD readable in sunlight with bright backlight. PSV mode is intended for pressure safety valve testing, and requires software to enable. (ConfigXP is a free download) Resolution: psi: 0.1 "Hg: 0.1 kg/cm2: 0.001 bar: 0.001 kPa: 0.1 MPa: 0.0001 |
Accuracy | 0 to 20% of range: ± (0.02% of full scale)* 20 to 110% of range: ± (0.1 of reading) Vacuum: ± (0.25% of full scale)** Not recommended for continuous use below -1 bar *Full scale is 100% of the range **Full scale = -1 bar |
Temperature | Operating: 14 to 122°F (-10 to 50°C) non-condensing. No change in accuracy over operating temperature range. Gauge must be zeroed to achieve rated specification Storage: -40 to 167°F (-40 to 75°C) battery should be removed if stored for more than one month |
Sensor | Wetted materials: Wrench tight 316 stainless steel Finger tight 316 stainless steel and Viton (internal o-ring) Diaphragm seal fluid: Dow corning 200 Connection: Crystal CPF female (U.S patent no. 8,794,677) All welded, with a permanently filled diaphragm seal Metal to metal cone seal; O-ring can be removed if necessary ¼" male NPT adapter included unless BSP, M20, or 15KPSI is specified ¼" medium pressure tube system compatible with HiP LM4 and LF4 series, Autoclave Engr SF250CX male and female series |
Datalogging | Capacity: 32,000 data points Storage type: Non-volatile flash memory Minimum interval: 1 second Maximum interval: 18 hours Minimum event duration: 250 mS*** ***Logging type- average with peaks These specifications are only applicable with the purchase of the DataLoggerXP which is sold separately |
Power | Batteries: Three size AA (LR6) batteries Battery life: 1500 hours typical (alkaline battery) Ultra low power: 1 year, typical with 20 minute recording interval in LT5 mode Battery indicator: 3-segment Battery Icon: Full battery; used battery; low battery Dead battery indication: batt |
Housing | Diecast aluminum |
Keypad and Labels | UV resistant polyester |
Data/Communication | Digital interface: RS232, DB-9F (for hazardous location product warnings, refer to the operation manual) |
Media Compatibility | Liquids and gases compatible with 316 stainless steel |
LCD Protection | From impact damage by 0.06" (1.5 mm) thick polycarbonate lens under polyester window. |
Submersible | To 3.3' (1 m) for 30 minutes [IEC 60529] |
Plating | Nickel plating over low copper, marine grade aluminum |
Rating | IP66 and IP67 |
Certifications | This digital pressure gauge complies with the Australian Radiocommunications (Electromagnetic Compatibility) Standard 2008 Crystal Engineering declares that this digital pressure gauge is in accordance with the ATEX Directive, the Electromagnetic Compatibility Directive, and the Pressure Equipment Directive per our declaration(s) This digital pressure gauge is approved for use as a portable test instrument for marine use and complies with Det Norsjke Veritas' rules for classification of ships, high speed and light craft, and offshore standards |
Dimensions | 5.59 x 1.42 x 4.5" (142 x 36.1 x 4.5 mm) |
Weight | 1.2 lbs (562 g) with batteries |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.