null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

Armada Pro900 Underground Cable Locator with dual frequency

No reviews yet Write a Review
$2,520.90
SKU:
Pro900
Availability:
1 in Stock
5 customers are viewing this product

Armada Pro900 Underground Cable Locator with dual frequency

$2,520.90

Availability: 1 in Stock

Armada Technologies Pro900 Offers

The Armada Pro 900 cable wire locator consists of a transmitter with a broadcast antenna inside and a receiver that tracks irrigation wires, and lost valves and finds major faults in cables. The transmitter is the long gray box that also serves as the carrying case and the receiver is the yellow and black wand.

The Pro900 is an excellent locator to track outdoor lighting lines, telephone cables, and AC power lines. The Armada wire locator includes an AC noise rejection system, which makes locating more accurate.

Features

  • Three Modes of Connection for Flexibility and Safety
  • Adjustable Power with Dual Frequencies for Different Locating Situations
  • AC Power Tracking
  • Pro900 Features Extended Range for the Largest Irrigation Systems
  • Power Hum Rejection for Fast and Accurate Tracking
  • Sealed Controls and Display for Durability and Reliability
  • Wireless Inductive Antenna or Clamp Modes
  • Two Direct Connect Frequencies - 2 kHz and 33 kHz
  • Passive 50/60 Hz AC Tracking
  • Option to Choose Null or Peak Tracing Modes
  • Incorporates three different locating frequencies
  • Tracks metallic cabling, including CATV, electrical, telephone, sprinkler, and lighting.
  • Transmits solid or intermittent signals that are easy to follow.
  • Offers two inductive mode capabilities.
  • Features both the new IC3 inductive clamp and inductive antenna modes.
  • Incorporates a 50/60Hz passive locating mode, which identifies electrical sources (power cables) and tracks them.
  • Identifies the path of 50/60 Hz underground cables without disconnecting or connecting to the cable.
  • Uses the triangulation method for depth determination.
  • Armada comes with two frequencies - 2kHz and 33kHz - to increase accuracy of locating.
  • Pro900 also comes with passive mode that locates 50/60Hz frequency to locate live electrical wires.
  • The inductive clamp enables locating without a direct connection to a wire.
  • The inductive antenna enables to scan a dig area for any possible wires, cables and/or metallic pipes.
  • Excellent for tracking irrigation wires, lost valves, major damage to cables, outdoor lighting wires, cable and telephone lines, and AC power lines
  • Tracking range depth: 8 feet
  • Tracks up to 5,000 feet with direct connection
  • Innovative digital interference suppression
  • Powered via battery or AC wall outlet
  • Uses two direct connection frequencies (2 kHz, 33 kHz)
  • Uses 175 kHz via clamp or internal broadcast antenna
  • Use inductive antenna or clamp mode
  • Features 50/60Hz AC Tracking
  • Switch between null or peak tracking modes
  • Two selectable tracking tones: Solid or beeping
  • Visual bar graph and audible beeps via speaker or stereo headset
  • Backlit display
  • Efficient battery life
  • Automatic shut-off

This advanced cable locator provides a clear, clean, interference-free signal. No buzzing, no AC cracking, no drowning of your signal beneath the local electrical transformer or electrical cable. All the interference is filtered out. The user is then able to clearly hear the beeping or continuous tone that is easy to follow and easy to track. The operation is simple. The transmitter places a specific tracing signal onto the metallic conductor you are trying to locate. This creates an AC signal on the cable and produces an electromagnetic field around the cable. The signal is received when the wand or receiver is close and the feedback is given in three different ways: audible external speaker, headset, or on the signal bar graph on the receiver's display screen.

The receiver and transmitter must always be in the same mode (Direct Clip-On, Broadcast, or Passive) to operate correctly. In tracing circuits, it is important to note, that a return path needs to be present. This return path completes the circuit. Usually, this will be the earth-ground stake. The signal travels down the cable and returns to the ground stake. You don't have to use a ground stake, but you do have to give the signal a way to return to the transmitter, so a common wire could work as well.

The tracing signal will always move on the path of least resistance. You can choose out of two tracing frequencies - 2 kHz and 33 kHz in direct connection mode - to facilitate more accurate tracing or gain more distance. The total distance in direct connection æ'mode reaches up to 5,000 feet, and the locating depth is up to 8 feet. Finding a wire is easier, as Armada's advanced cable locator comes with a stereo headset to listen to tracing tone in addition to a standard speaker. Hence locating in a noisy environment is easy.

The broadcast frequency of 175 kHz can be used to couple the signal to all underground utilities, so you can find them, without being connected to them directly. This method is widely used to scan any area before digging, just to find out, if it's safe to start excavating in the area.

The Armada Pro900 underground cable locator finds cables in 4 different ways. First, via direct connection: while the transmitter is connected to a cable it sends a signal of either 2kHz or 33kHz and the locator will react to that cable. Second, when the inductive clamp is connected to a cable or conduit in which the cable is placed, the signal will be induced into the cable. This mode is very useful when there is no direct access to the target cable.

Third, an area scanning mode - the inductive antenna sends a signal to a ground where cables are located, and the locator will map out cables and pipes present within the surrounding area. This mode is very useful for most construction work when the user wants to determine the presence of any cables within a construction work zone. These wireless connection methods of the inductive clamp or inductive antenna give the Pro900 incredible flexibility when tracking wires and cables that you either can't or don't wish to disconnect, like live electrical or in-service CATV lines.

The fourth mode is passive; the locator will pick up 50/60 Hz frequency from live electrical lines. Once the wand is turned on, simply search an area until you hear a buzzing sound. There is no beeping as the transmitter is not used. Contractors can identify the path of 50/60 Hz underground cables without disconnecting them or connecting to the cable.

However, the passive mode might not detect power cabling if there is no live electrical current present in the cable at the time. Therefore, you should NOT rely on the 50/60 Hz passive mode as the sole method of locating power lines.

The Armada Technologies Pro 900 can also be used to find breaks or severe wire damage. However, unlike when you are tracing a wire, the break or wire damage will cause the signal to stop at the point of the break. Either the speaker or the analog meter on the receiver will indicate this drop. Generally, the greater the damage to the wire, the greater the drop-off at the point of damage.

The Pro900 uses the triangulation method for depth determination. Simply acquire the wire path in the null mode, place the receiver at a 45-degree angle to that path, move the receiver horizontally in the direction the receiver wand is leaning and when you get the null again, the distance traveled is the depth of the wire.

The Armada Tech Pro 900 has two options for powering the transmitter: AC main power or 8 D alkaline batteries installed inside the transmitter battery compartment. When AC power outlets are located close by, the AC adapter is a great way to power the transmitter as it provides constant power and does not diminish the batteries.

Both the transmitter and receiver have a battery indicator so you always know the amount of juice left in your batteries.

Applications

  • General wiring like telephone or CATV
  • Electrical wiring
  • Contractors working with landscape lighting, invisible fencing
  • Sprinkler System Service and Maintenance
  • Garden and Landscape irrigation


Armada Technologies Pro900 Specifications

Specifications

Armada Pro900 Underground Cable Locator with Dual Frequency
Tracking Range (LO-F, 2kHz)Depth: 8 feet (2.4 m), Wire length: 5,000 feet (1.5 km) with direct connection, Wire length: unlimited with broadcast mode and leapfrogging
Tracking SignalsFrequency One (LO-F): 2 kHz direct connect, Frequency Two (HI-F): 33 kHz direct connect, Frequency Three (BCAST): 175 kHz via clamp or internal antenna, Passive AC: 50/60 Hz
AntennasReceive Peak – 2/33 kHz, Receive Null – 2/33 kHz, Receive Peak – 175 kHz, Transmit Internal – 175 kHz
Clamp Interior Diameter3.5 inches (85 mm)
Direct Connect Signal Output900 V peak with no load 1 W maximum
Audio OutputHeadset and Loudspeaker
Power SourceTransmitter: Eight (8) ‘D’ cells (LR20) alkaline or NiMH, or External 120 Vac Powering, Receiver: One (1) 9 V (6LR61)


What's included with the Armada Technologies Pro900
  • Pro900R Receiver
  • Pro900T Transmitter
  • IC2 Inductive Clamp
  • GS1 Ground Stake
  • ProH3 Stereo Headset
  • Pro900CS Cordset
  • ProCH4 AC Adapter
  • User Guide
  • One-Year Warranty
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns