have questions?
Always the correct part
We know our products
Fast & Reliable
Suitable for engineering and science labs where size constraints are critical, this kit reliable and comprehensive results and features longwave imaging and thousands of temperature measurement points across your target. For industrial and research and development labs, this kit features advanced analysis software and a dependable temperature measurement solution.
Features
Visualize heat
These non-contact temperature sensors are enhanced with thermal imaging.
Communicate data seamlessly
Stream temperature linear output through GenICam compliant software.
Designed to fir your applications
Get more out of your data with advanced analysis tools.
Applications
Image and Optical Data | |
IR Resolution | 640 x 512 |
Thermal Sensitivity/NETD | <0.05°C at 30°C (86°F)/50 mK |
Image Frequency | 30 Hz |
Focus | Fixed |
Detector Data | |
Type | Uncooled VOx microbolometer |
Spectral Range | 7.5 to 13 µm |
Pitch | 17 µm |
Time Constant | 12 ms (typical) |
Measurement | |
Object Temperature Range | -13 to 212°F (-25 to 100°C) -40 to 1022°F (-40 to 550°C) |
Accuracy | ±9°F (±5°C) or 5% of reading |
Ethernet | |
Type | Gigabit ethernet, control and image |
Standard Connector | IEEE 802.3, RJ-45 |
Communication | GigE Vision version 1.2, client API GenICam compliant |
Image Streaming | 8-bit monochrome at 30 Hz Signal linear/DDE; automatic/manual; Flip H&V |
Bit Rate | 14-bit 320 x 256 at 30 Hz Signal linear/DDE; Temperature linear GigE vision and GeniCam compatible |
Power | Power over ethernet, PoE IEEE 802.3af class 0 power |
Protocols | TCP, UDP, ICMP, IGMP, DHCP, GigEVision |
Digital Input/Output | |
Input | 1 x opto-isolated,"0" <1.2 V DC,"1" = 2 to 25 V DC |
Output | 1 x opto-isolated, 2 to 40 V DC, maximum 185 mA |
Voltage | Isolation: 500 VRMS Supply: 2 to 40 V DC, maximum 200 mA |
Connector | 12-pole M12 connector (shared with digital synchronization and external power |
Synchronization | In: Frame synch in to control camera 1x, non-isolated In type: LVC buffer at 3.3 V,"0" <0.8 V,"1" >2 V Out: Frame synch out to control another Ax5 unit 1x, non-isolated Out type: LVC buffer at 3.3 V,"0" = 24 MA maximum,"1" = 24 mA maximum Digital connector type: 2-pole M12 connector (shared with digital I/O and external power) |
General Specifications | |
External Power | Operation: 12/24 V DC, <3.5 W nominal <6 W absolute maximum Connector type: 12-pole M12 connector (shared with digital I/O and digital synchronization) Voltage: Allowed range 10 to 30 V DC |
Temperature Range | Operating: 5 to 140°F (15 to 60°C) Storage: 40 to 158°F (40 to 70°C) |
Humidity (Operating and Storage) | IEC 60068-2-30/24 h 95% relative humidity 77 to 104°F (25 to 40°C) |
EMC | EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR part 15 class B (Emission) |
Encapsulation/Bump/Vibration | IP 40 (IEC 60529), 25 g (IEC 60068-2-27), 2 g (IEC60068-2-6), MILSTD810G |
Mounting | Tripod: UNC ¼" to 20 (three sides) Base: 4 x M3 thread mounting holes (bottom) |
Housing Material | Magnesium and aluminum |
Dimensions | With 50 mm lens: 5.7 x 2.3 x 2.3" (141.1 x 58.4 x 58.4 mm) With 100 mm lens: 7.7 x 3.2 x 3.2" (196.4 x 82 x 82 mm) |