Fluke 15B+ ESP OffersUnlock professional-grade precision, durability, and safety with the Fluke 15B+ digital multimeter. This meter packs all the core functionality you need in a digital multimeter into a portable, rugged form tool that’s easy to use with one hand, even with gloves on. From AC/DC voltage and current measurements up to 1000 V and 10 A, to comprehensive capabilities including resistance, capacitance, and frequency checks, this digital multimeter is your go-to for troubleshooting a wide array of electrical issues.
The CAT III 600 V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. Ideal for both DIY enthusiasts and early career electricians looking to streamline their toolkit, this digital multimeter is a reliable and versatile addition to your toolkit.
Features
Applications
Volts | AC: Range: 4 V, resolution: 0.001 V, accuracy: ±(1% + 3) Range: 40 V, resolution: 0.01 V, accuracy: ±(1% + 3) Range: 400 V, resolution: 0.1 V, accuracy: ±(1% + 3) Range: 1000 V, resolution: 1 V, accuracy: ±(1% + 3)Overload protection: 1000 VInput impedance (nominal): >10 MΩ, <100 pFCommon mode rejection ratio: >60 dB at DC, 50 or 60 Hz DC: Range: 4 V, resolution: 0.001 V, accuracy: ±(0.5% + 3) Range: 40 V, resolution: 0.01 V, accuracy: ±(0.5% + 3) Range: 400 V, resolution: 0.1 V, accuracy: ±(0.5% + 3) Range: 1000 V, resolution: 1 V, accuracy: ±(0.5% + 3)Overload protection: 1000 VInput impedance (nominal): >10 MΩ, <100 pFCommon mode rejection ratio: >100 dB at dc, 50 or 60 HzNormal mode rejection ratio: >60 dB at 50 or 60 Hz |
Millivolts | AC:Range: 400 mV Resolution: 0.1 mV Accuracy: ±(3% + 3) Overload protection: 400 mVInput impedance (nominal): >1 MΩ, <100 pFCommon mode rejection ratio: >80 dB at 50 or 60 HzDC: Range: 400 mV Resolution: 0.1 mV Accuracy: ±(1% + 10) Overload protection: 400 mVInput impedance (nominal): >1 MΩ, <100 pFCommon mode rejection ratio: >80 dB at 50 or 60 Hz |
Diode Test* | Range: 2 V Resolution: 0.001 V Accuracy: ±10%*Typically, open circuit test voltage is 2 V and short circuit current is <0.6 mA |
Resistance | Range: 400 Ω, resolution: 0.1 Ω, accuracy: ±(0.5% + 3) Range: 4 kΩ, resolution: 0.001 kΩ, accuracy: ±(0.5% + 2) Range: 40 kΩ, resolution: 0.01 kΩ, accuracy: ±(0.5% + 2) Range: 400 kΩ, resolution: 0.1 kΩ, accuracy: ±(0.5% + 2) Range: 4 MΩ, resolution: 0.001 MΩ, accuracy: ±(0.5% + 2) Range: 40 MΩ, resolution: 0.01 MΩ, accuracy: ±(1.5% + 3) |
Capacitance* | Range: 40 nF, resolution: 0.01 nF, accuracy: ±(2% + 5) Range: 400 nF, resolution: 0.1 nF, accuracy: ±(2% + 5) Range: 4 µF, resolution: 0.001 µF, accuracy: ±(5% + 5) Range: 40 µF, resolution: 0.01 µF, accuracy: ±(5% + 5) Range: 400 µF, resolution: 0.1 µF, accuracy: ±(5% + 5) Range: 1000 µF, resolution: 1 µF, accuracy: ±(5% + 5)*Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range) |
Current µa (40 to 400 Hz) | AC: Range: 400 μA, resolution: 0.1 μA, accuracy ±(1.5% + 3)Range: 4000 μA, resolution: 1 μA, accuracy: ±(1.5% + 3)_x000D_ DC:Range: 400 μA, resolution: 0.1 μA, accuracy ±(1.5% + 3)Range: 4000 μA, resolution: 1 μA, accuracy: ±(1.5% + 3)_x000D_ |
AC Current (40 to 400 Hz) | mA:Range: 40 mA, resolution: 0.01 mA, accuracy: ±(1.5% + 3)Range: 400 mA, resolution: 0.1 mA, accuracy: ±(1.5% + 3)A:Range: 4 A, resolution: 0.001 A, accuracy: ±(1.5% + 3)Range: 10 A, resolution: 0.01 A, accuracy: ±(1.5% + 3) |
Maximum Voltage Between Any Terminal and Earth Ground | 1000 V |
Display | LCD 4000 counts, updates 3 secondsBacklight: Yes |
Altitude | Operating: 6562' (2000 m) Storage: 39,370' (12,000 m) |
Fuse Protection for Current Inputs | 440 mA, 1000 V fast fuse, Fluke specified part only 11 A, 1000 V fast fuse, Fluke specified part only |
Power | Battery type: 2 x AA, NEDA 15 A, IEC LR6Battery life: 500 hours minimum |
Environmental Conditions | Operating temperature: 32 to 104°F (0 to 40 °C) Storage: -22 to 140°F (-30 to 60°C)Operating humidity: ≤90% RH at 50 to 86°F (10 to 30°C); ≤75% RH at 86 to 104 °F (30 to 40°C), non-condensing <50°F (<10°C)Operating humidity 40 MΩ range: ≤80% RH at 50 to 86°F (10 to 30°C); ≤70% RH at 86 to 104°F (30 to 40°C)Temperature coefficient: 0.1 x (specified accuracy) /°C (<64.4 or >82.4°F (<18 or >28°C) |
Certifications | IP rating: IP40Safety: IEC 61010-1, IEC 61010-2-030 CAT III 600 V, Pollution Degree 2Electromagnetic compatibility: IEC 61326-1: Portable EMC Environment |
Dimensions | 7.2 x 3.6 x 1.95" (183 x 91 x 49.5 mm) |
Weight | 1 lbs (455 g) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.