Fluke 1664FC US OffersVerify the safety of electrical installations with this installation multifunction tester capable of ensuring that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364. Additionally, this tester features cloud storage to save your test results and reduce transcription errors.
Features
Reduce test time up to 40% with auto test
Auto test does five required installation tests in one sequence, including selectable type A, AC and RCD auto test, ensuring compliance with local installation regulations. It reduces the number of manual connections, decreases the possibility of making errors and reduces test time up to 40% from previous models
Insulation pretest
Protect the installation. Avoid costly mistakes. The installation tester is the only installation with “insulation pretest," which warns you about potentially serious and costly mistakes. If the tester detects that appliances are connected to the system during test, it will stop the insulation test and provide a visual and audible warning. This helps eliminate accidental damage to peripheral equipment and keeps your customers happy.
Share from anywhere
Save time, eliminate data entry by wirelessly syncing measurements directly from your installation tester and share with your team. Having access to measurements simultaneous at the inspection site and from the office or an off-site location enables faster decision making and real time collaboration between team members.
Cloud storage
Retrieve stored results from anywhere. Cloud storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. Uses radio-enabled test tools and a mobile app to transfer measurements straight from the field to a secure cloud location, where the data can be accessed by team members. Plus you can import the data into DMS to process and generate certificates.
Applications
| AC and DC Voltage Measurement Trms | Range: 500 VResolution: 0.1 VInput impedance: 3.3 MΩOverload protection: 660 V rms |
| Continuity Testing (RLO) | Range (autoranging): 20 Ω/200 Ω/2000 ΩResolution: 0.01 Ω/0.1 Ω/1 ΩOpen circuit voltage: >4 V |
| Insulation Resistance Measurement (RISO) | Test voltages: 50/100/250/500/1000 VTest voltage: 50 V, Insulation resistance range: 20 MΩ/50 MΩ, Test current: 1 mA at 50 kΩTest voltage: 100 V, Insulation resistance range: 20 MΩ/100 MΩ, Test current: 1 mA at 100 kΩTest voltage: 250 V, Insulation resistance range: 20 MΩ/200 MΩ, Test current: 1 mA at 250 kΩTest voltage: 500 V, Insulation resistance range: 20 MΩ/200 MΩ/500 MΩ, Test current: 1 mA at 500 kΩTest voltage: 1000 V, Insulation resistance range: 20 MΩ/200 MΩ/1000 MΩ, Test current: 1 mA at 1 MΩ |
| Insulation Safety Pretest | Requires to connect the tester to L, N and PE |
| Loop and Line Impedance (ZI) | Range: 10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 ΩResolution: 1 mΩ/ 0.01 Ω/ 0.1 Ω/1Ω |
| Prospective Earth Fault Current, PSC Test | Range: 1000 A/10 kA (50 kA)Resolution: 1 A/0.1 kAComputation: Prospective earth fault current (PEFC) or prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively |
| RCD Testing, RCD Types Tested | RCD Type: AC (responds to AC)General, no delayTime delayResponds to pulsed signalResponds to smooth DC signal |
| RCD Trip Time Test (ΔT) | Current Settings (1000 mA type AC only. 700 mA maximum type A in VAR mode, VAR mode not available for type B)10/30/100/300/500/1000 mA – VAR10/30/100 mAMultiplier: x½, x 1Measurement range RCD type G:310 ms50 msMeasurement range RCD type S:510 ms160 ms |
| RCD Trip Current Measurement/Ramp Test (I ΔN) | Current range: 30 to 110% of RCD rated current (30 to 150% for Type A IΔN >10 mA)Step size: 10% of IΔN (5% for Type B)Dwell time type G: 300 ms/stepDwell time type S: 500 ms/stepMeasurement Accuracy: ±5%Notes: 30 to 210% for Type A IΔN = 10mA, 20 to 210% for Type BSpecified trip current ranges (EN 61008-1):50 to 100% for Type AC35 to 140% for Type A (>10 mA)35 to 200% for Type A (≤10 mA)50 to 20 % for Type B |
| Earth Resistance Test (RE) | Range: 200 Ω/2000 ΩResolution: 0.1 Ω/1 ΩFrequency: 128 HzOutput voltage: 25 V |
| Phase Sequence Indicaton | Icon: Phase sequence indicator is activeRange: 100 to 500 VDisplay: “1-2-3": or “3-2-1" |
| Performance | EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10 |
| Overvoltage | CAT III 500 V, CAT IV 300 V |
| Safety | Complies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and CAN/CSA c22.2 No. 1010 |
| Sealing | IP 40 |
| Battery | 1.5 V type AA (IEC LR6), 6 pcs |
| Dimensions | 3.93 x 9.84 x 4.92" (10 x 25 x 12.5 cm) |
| Weight | Approximately 2.86 lbs (1.3 kg) including batteries |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.