Guaranteed Fitment
Always the correct part
have questions?
Always the correct part
We know our products
Fast & Reliable
Availability: 4 in Stock
Fluke 283FC OffersThe 283 FC includes TL175-HV CAT III 1500 V/CAT IV 1000 V safety-rated silicone TwistGuard test leads for working in higher voltage environments without compromising safety, giving you more flexibility when testing voltage, millivoltage, resistance, continuity, or capacitance. The backlit LCD screen and illuminated keypad make it easier to work in various lighting conditions while the magnetic hanging kit frees up your hands while testing. The 283 FC also includes a custom hard carrying case that protects your investment while you transport it.
Features
User-Defined Limit Gauge
On large-scale PV projects where you’re taking repetitive measurements and expect consistent results, the user-defined limit gauge becomes a vital time-saving tool. The adjustable limit gauge can trigger audio and visual indications whenever a measurement falls outside your expected range. This saves you time letting you quickly evaluate measurement results, increasing your confidence in the system's performance, and helping to identify potential issues that need to be addressed.
With the dedicated limit gauge button, you can easily turn the limit gauge warnings on and off, set up new measurement parameters, or select from previously used parameter profiles. This customization streamlines troubleshooting, allowing you to quickly identify measurement deviations or errors, and helps maintain optimal solar installation performance.
Unique Multimeter Readiness Self-Check
The size and location of utility-scale solar sites can present unique challenges whether they’re logistical, environmental, or testing related. Because of that, you want to have confidence that your meter is fully functional, capturing the right data every time so you don’t have to do the same job twice. The 283 FC features a unique integrated multimeter readiness selfcheck, that ensures your meter is in proper working order before you take your next reading. This quick self-check is an additional readiness test that gives you valuable insight to the status of your meter’s calibration, battery life availability, test lead functionality, and AC/DC voltage measurement functionality so you can be confident that your meter is ready to work when you are.
Logging/Saving
The 283 FC offers convenient logging and saving features that set it apart from other digital multimeters. With a built-in real-time clock, each measurement can be time- and date-stamped for accurate recordkeeping. The multimeter has internal memory to save and log measurements, which can then be easily transferred to Fluke Connect for further analysis. Additionally, you have the flexibility to customize logging durations and intervals, ensuring the logging process matches the specific needs of the system you are testing.
Fluke Connect™ with Fluke Cloud™ Storage
Fluke Connect™ compatibility provides convenient features to enhance your troubleshooting experience. As part of the Fluke Connect family, the 283 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email and collaborate in real time with other colleagues with ShareLive™ video calls or email. The table view feature organizes measurements, notes, and images in a clear and efficient manner, making it easier to reference data, identify issues, and generate reports for customers. Fluke Connect™ with Fluke Cloud™ Storage streamlines your workflow and ensures accurate data storage and organization.
Applications
Function | |
AC Volts | Range: 6.000 VResolution: 0.001 VAccuracy: 1.0% + 3 (45 Hz to 500 Hz)Range: 60.00 VResolution: 0.01 VAccuracy: 1.0% + 3 (45 Hz to 500 Hz)Range: 600.0 VResolution: 0.1 VAccuracy: 2.0% + 3 (500 Hz to 1 kHz)Range: 1000 VResolution: 1 VAccuracy: 2.0% + 3 (500 Hz to 1 kHz) |
DC Volts | Range: 6.000 VResolution: 0.001 VAccuracy: 0.09% + 3Range: 60.00 VResolution: 0.01 VAccuracy: 0.09% + 3Range: 600.0 VResolution: 0.1 VAccuracy: 0.15% + 2Range: 1500 VResolution: 1 VAccuracy: 0.15% + 2 |
DC mV | Range: 600.0 mVResolution: 0.1 mVAccuracy: 0.09% + 2 |
AC mV | Range: 600.0 mVResolution: 0.1 mVAccuracy: 1.0% + 3 (45 Hz to 500 Hz)Range: 600.0 mVResolution: 0.1 mVAccuracy: 2.0% + 3 (500 Hz to 1 kHz) |
Continuity | Range: 600.0 ΩResolution: 1 Ω |
Resistance | Range: 600.0 ΩResolution: 0.1 ΩAccuracy: 0.5% + 4Range: 6.000 kΩResolution: 0.001 kΩAccuracy: 0.5% + 4Range: 60.00 kΩResolution: 0.01 kΩAccuracy: 0.5% + 4Range: 600.0 kΩResolution: 0.1 kΩAccuracy: 0.5% + 4Range: 6.000 MΩResolution: 0.001 MΩAccuracy: 1.5% + 4Range: 50.00 MΩResolution: 0.01 MΩAccuracy: 1.5% + 4 |
Capacitance | Range: 1000 nFResolution: 1 nFAccuracy: 1.2% + 2Range: 10.00 μFResolution: 0.01 μFAccuracy: 1.2% + 2Range: 100.0 μFResolution: 0.1 μFAccuracy: 10% typicalRange: 9999 μFResolution: 1 μFAccuracy: 10% typical |
Frequency | Range: 99.99 HzResolution: 0.01 HzAccuracy: 0.1% + 2Range: 999.9 HzResolution: 0.1 HzAccuracy: 0.1% + 2Range: 9.999 kHzResolution: 0.001 kHzAccuracy: 0.1% + 2Range: 99.99 kHzResolution: 0.01 kHzAccuracy: 0.1% + 2 |
AC VA (45 to 500 Hz) | Range: 360.0 VAResolution: 0.1 VAAccuracy: 2% + 1.0 VARange: 3.600 kVAResolution: 0.001 kVAAccuracy: 2% + 1.0 kVARange: 36.00 kVAResolution: 0.01 kVAAccuracy: 2% + 0.15 kVARange: 60.00 kVAResolution: 0.1 kVAAccuracy: 2% + 0.15 kVA |
DC VA | Range: 360.0 VAResolution: 0.1 VAAccuracy: 2% + 1.0 VARange: 3.600 kVAResolution: 0.001 kVAAccuracy: 2% + 1.0 kVARange: 36.00 kVAResolution: 0.01 kVAAccuracy: 2% + 0.15 kVARange: 90.00 kVAResolution: 0.1 kVAAccuracy: 2% + 0.25 kVA |
Environmental Specifications | |
Operating Temperature | -10 to 60°C (14 to 140°F) |
Storage Temperature | -30 to 70°C (-22 to 158°F) |
Humidity (without condensation) | 0 to 90%, 10 to 30°C (50 to 86°F)0 to 75%, 30 to 40°C (86 to 104°F)0 to 45%, 40 to 60°C (104 to 140°F) |
Protection | |
Electromagnetic compatibility | IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A |
Overvoltage category | CAT III 1500 V, CAT IV 1000 V |
Agency approvals | ETL (AMER and EMEA), CSA (APAC), CE, UK CA |
Drop test | 2 m (6.5') drop test |
Ingress protection | IP52 |
Mechanical and General Specifications | |
Counts | 6000 |
Battery life | > 150 hours typical, without backlight (Alkaline, 3 AA)> 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA) |
Dimensions | 22.5 x 10.5 x 5.7 cm (8.8 x 4.1 x 2.2") |
Weight | 0.7 kg (1.5 lb) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.