The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems. This clamp meter sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1 to 5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.

Advanced loop troubleshooting with the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing the transmitter. You can also apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators. Moreover, it offers mA or voltage output linear ramp or 25% step output.

Features

  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • Simulate 4 to 20 mA signals for testing control system I/O
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters
  • Source mA output signals in a linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp: Enables a logging DMM (289) or other device to record the 4 to 20 mA signal without breaking the loop
  • mA in/out: Simultaneously measure the mA signal with the clamp and source a mA signal
  • Apply a mA input signal to a device and measure its’ 4 to 20 mA output on devices such as valves or mA isolators
  • Power saving features, auto-off, backlight timeout extend battery life
  • DC voltage measurement to verify 24 V power supplies or voltage I/O signals
  • Source dc voltage to test input devices that accepts 1 to 5 volt or 0 to 10 volt signal
  • Voltage output linear ramp or 25% step output: Automatically change the voltage output for remote testing
  • Best in class accuracy of 0.2%
  • Delivers 0.01 mA resolution and sensitivity

Applications

  • HVAC/R Systems
  • Oil and Gas
  • Pharmaceuticals
  • Process Plants


Fluke 773 CAL Specifications

Specifications

mA MeasureYes
JawYes
mA MeasureYes
In CircuitYes
mA SourceYes
mA SimYes
Loop PowerYes
24 VYes
DC V SourceYes
0 to 10 VYes
DC V MeasureYes
0 to 30 VYes
Scaled mA Output to mA InputYes
mA In/OutYes
mA measurementResolution: 0 to 20.99 mAAccuracy: 0.2% + 5 countsNotes: Measured by clampResolution: 21.0 mA to 100.0 mAAccuracy: 1% + 5 countsResolution: 0 to 24.00 mAAccuracy: 0.2% + 2 countsNotes: Measured in series with test jacks
mA sourceResolution: 0 to 24.00 mAAccuracy: 0.2% + 2 countsNotes: Maximum mA drive: 24 mA into 1000 ohms
mA simulateResolution: 0 to 24.00 mAAccuracy: 0.2% + 2 countsNotes: Maximum voltage 50 V DC
Voltage sourceResolution: 0 to 10.00 V DCAccuracy: 0.2% + 2 countsNotes: 2 mA maximum drive current
Voltage measureResolution: 0 to 30.00 V DCAccuracy: 0.2% + 2 counts
Influence of earth’s field<0.12 mA
Vibration requirementsRandom 2 g, 5 Hz to 500 Hz
Drop testPasses 1 meter drop test (except the jaw)
EMI, RFI, EMCMeets applicable requirements in EN61326-1Note: For current measurement w/jaw, add 1 mA to specification for EMC field strengths of 1 V/m up to 3 V/m
IP ratingIP 40
Temperature coefficients0.1(/°C x specified accuracy for temperature < 64.4°F (18°C) or > 82.4°F (28°C))
Environmental ConditionsOperating temperature: 14 to 122 °F (-10 to 50 °C)Storage temperature: -13 to 140 °F (-25 to 60 °C)Operating humidity: < 90% @ < 86°F (30°C); < 75% @ 86 to 131 °F (30 to 55°C)Operating altitude: 0 to 2000 m
WarrantyThree-years, one-year on mA clamp assembly and cable
PowerBattery: 4 x 1.5 V, Alkaline, IEC LR6Battery life: 12 hours @ 12 mA source into 500 ohms
Dimensions1.625 x 3 x 9.75" (41.3 x 76 x 248 mm)
Weight14 oz (415 g)


What's included with the Fluke 773 CAL
  • Milliamp Process Clamp Meter
  • Test Leads
  • Detachable Clip
  • Mini Hook Test Leads
  • 4 x AA Alkaline Batteries (installed)
  • Magnetic Hanging Strap
  • Soft Carrying Case
  • Quick Reference Guide
  • Traceable Calibration Certificate With Data
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns