have questions?
Always the correct part
We know our products
Fast & Reliable
Availability: 15+ Weeks
Fluke 83V OffersFeatures
Electrical safety
All inputs are updated to the 3rd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Identify complex signal problems fast
When productivity is on the line and you need to solve problems fast, this multimeter delivers the accuracy and advanced troubleshooting capabilities you need.
Min/Max allows capture of signal changes
Voltage DC | |
Maximum Voltage | 1000 V |
Accuracy | ±(0.1% + 1) |
Maximum Resolution | 100 µV |
Voltage AC | |
Maximum Voltage | 1000 V |
Accuracy | ±(0.5% + 2) |
Maximum Resolution | 0.1 mV |
Current DC | |
Maximum Amps | 10 A (20 A for 30 seconds maximum) |
Amps Accuracy | ±(0.4% + 2) |
Maximum Resolution | 0.01 mA |
Current AC | |
Maximum Amps | 10 A (20 A for 30 seconds maximum) |
Amps Accuracy | ±(1.2% + 2) |
Maximum Resolution | 0.1 µA |
Resistance | |
Maximum Resistance | 50 MΩ |
Accuracy | ±(0.4% + 1) |
Maximum Resolution | 0.1 Ω |
Capacitance | |
Maximum Capacitance | 9999 µF |
Accuracy | ±(1% + 2) |
Maximum Resolution | 0.01 nF |
Frequency | |
Maximum Frequency | 200 kHz |
Accuracy | ±(0.005% + 1) |
Maximum Resolution | 0.01 Hz |
Duty Cycle | |
Maximum Duty Cycle | 99.9% |
Accuracy | ±(0.2% per khz + 0.1%) |
Maximum Resolution | 0.1% |
Conductance | |
Maximum Conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) |
Maximum Resolution | 0.01 nS |
Diode | |
Range | 3 V |
Resolution | 1 mV |
Accuracy | ±(2% + 1) |
Duty Cycle Range | |
Accuracy | Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications | |
Operating Temperature | -4 to 131°F (–20 to 55°C) |
Storage Temperature | -40 to 140°F (–40 to 60°C) |
Humidity (Without Condensation) | 0 to 90% between 32 to 95°F (0 to 35°C) 0 to 70% between 95 to 131°F (35 to 55°C) |
Operating Altitude | 6561.68' (2000 m) |
Mechanical and General Specifications | |
Display | Digital: 6000 counts updates 4/sec Analog: 32 segments, updates 40/sec Frequency: 19,999 counts, updates 3/sec at > 10 Hz |
Battery Life | Alkaline battery around 400 hours typical, without backlight |
Shock | 3.3' (1 m) drop per IEC 61010–1:2001 |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
Dimensions | 7.9 x 3.9 x 2" (201 x 98 x 52 mm) |
Weight | 0.78 lbs (355 g) |
Safety Specifications | |
Over Voltage Category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
Agency Approvals | CSA, TÜV |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)