Guaranteed Fitment
Always the correct part
have questions?
Always the correct part
We know our products
Fast & Reliable
Identifies complex signal problems fast
Provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment. On top of that, this industrial multimeter effectively performs in loud, high energy, and high altitude locations. Features a low pass filter which supports precise frequency measurements on VFDs and acquires intermittents as quickly as 250 µS.
Use this multimeter to measure AC currents up to 10 A directly. Also, features a built-in thermometer that enables you to take temperature readings without having to carry a separate instrument and more. Plus, comes with a bright, two-level backlit display which allows you to see the results better in dim light.
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. Although, this industrial multimeter is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
Features
Applications
How to choose the best DMM for your job?
Multimeter Selection GuideFluke TL224 SureGrip Silicone Insulated Test Leads
Features
Fluke AC220 SureGrip Alligator Clips
Features
Fluke TL238 SureGrip Test Lead Set for High Energy Environments
Features
Fluke TPAK ToolPak Magnetic Meter Hanger
Take hands-free measurements with this magnetic meter hanger. The kit allows you to hang your meter in a variety of waysincluding on nails, hooks and many other objectssolving any hanging and positioning problem you may face.
Please note that this product doesn't clip into the Fluke T6 Series like it does for other Fluke meters. Instead, you must simply feed the Velcro loop through the slot on the back of the T6 and Velcro it together.
Features
Fluke 80BK-A Integrated DMM Temperature Probe
Features
Fluke C35 Soft Carrying Case
Dimensions: 8.7 x 5.5 x 2.6" (220 x 140 x 65 mm)
Todays thermal imagers have become a realistic solution for everyday electrical maintenance as they are rugged, easy to use, and much more affordable than even just a few years ago. It's a straight-forward process, where a qualified technician or electrician points the thermal imager at the equipment in question and scans the immediate area, looking for unexpected hot spots. The imager produces a live image of the heat emitted from the equipment and with the quick squeeze of the trigger, a thermal image is captured. When the inspection is complete, the image is uploaded to a computer, Apple®, iPhone® or iPad® for closer analysis, reporting, and future trending.
There are a few basic how-tos to consider... electrical load, safety, and emissivity. In this application note, we walk you through these, as well as the Top 5 Checklist, and much more.
Read the Application NoteVoltage DC | Max voltage: 1000 V Accuracy: ±(0.05% + 1) Maximum resolution: 10 µV |
Voltage AC | Max voltage: 1000 V Accuracy: ±(0.7% + 2) True RMS AC bandwidth: 20 kHz with low pass filter; 3 db @ 1 kHz Maximum resolution: 0.1 mV |
Current DC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(0.2% + 2) Maximum resolution: 0.01 µA |
Current AC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(1.0% + 2) True RMS Maximum resolution: 0.1 µA |
Resistance | Maximum resistance: 50 M? Accuracy: ±(0.2% + 1) Maximum resolution: 0.1 ? |
Capacitance | Maximum capacitance: 9999 µF Accuracy: ±(1% + 2) Maximum resolution: 0.01 nF |
Frequency | Maximum frequency: 200 kHz Accuracy: ±(0.005% + 1) Maximum resolution: 0.01 Hz |
Temperature Measurement | -328 to 1994°F (-200 to 1090°C) excluding probe |
80 BK Temperature Probe | -40 to 500°F (-40 to 260°C), 2.2°C or 2% whichever is greater |
Operating Temperature | -4 to 131°F (-20 to 55°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Altitude | 6561' (2000 m) |
Dimensions | 7.9 x 3.9 x 2.05" (201 x 98 x 52 mm) with Holster |
Weight | 0.8 lb (355 g) |
Battery life | Alkaline approximately 400 h typical, without backlight |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.