Fluke 3000-FC OffersSafety and productivity are key to any job. The reliable Fluke 3000 FC wireless multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600 V, CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems. The Fluke 3000 FC works with the Fluke Connect® software system to keep you safe from hazardous measurement situations by allowing you to read your measurements from afar.
Flexibility to grow your wireless test tool system. The wireless digital multimeter functions as a hub for Fluke Connect® wireless modules so you have the versatility to add to your wireless test tool system how you want, when you want. The 3000 FC can display its own measurements plus readings from up to three modules tools simultaneously from up to 20 meters away.
Manage your data more easily. With this Fluke Connect®-enabled multimeter, you can connect to your mobile device or PC for further analysis and reporting. Fluke Connect® software also helps you pinpoint intermittent faults faster by logging and trending measurements. With more and more of a need to integrate reporting and documentation of your facilities' health, the Fluke Connect® software system allows you to view different measurements—thermal, mechanical and electrical—from the same piece of equipment at the same time.
Features
Productivity
Convenience
Safety
AC Voltage | |
Range | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | 1.0 % + 3 from 45 Hz to 500 Hz 2.0 % + 3 from 500 Hz to 1 kHz |
DC Voltage | |
Range | 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
Accuracy | 0.09 % + 2 0.09 % + 2 0.15 % + 2 |
Continuity | |
Range | 600 Ω |
Resolution | 1 Ω |
Accuracy | Meter beeps at <25 Ω, beeper detects opens or shorts of 250 µs or longer. |
Resistance | |
Range | 600.0 Ω 6.000 kΩ 60.00 kΩ 60.00 kΩ 600.0 kΩ 50.00 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | 0.5 % + 2 @ 600.0 Ω 0.5% + 1 from 6.000 to 600.0 kΩ 1.5 % + 3 @ 50.00 MΩ |
Diode Test | |
Range | 2.000 V |
Resolution | 0.001 V |
Accuracy | 1 % + 2 |
Capacitance | |
Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy | 1.2 % + 2 from 1000 nF to 100 µF 10 % Typical @ 9999 µF |
AC and DC Current | |
Range | 60.00 mA 400.0 mA |
Resolution | 0.01 mA 0.1 mA |
Accuracy | AC: 1.5 % + 3 from 45 Hz to 1 kHz DC: 0.5 % + 3 |
Frequency | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1 % + 1 |
Min/Max Recording | |
Accuracy | DC Functions: ±12 counts for changes >350 ms in duration AC Functions: ±40 counts for changes >900 ms in duration |
General Specifications | |
Maximum Voltage Between Any Terminal and Earth Ground | 1000 V DC or AC RMS |
Fuse Protection from A Inputs | 0.44 A (44/100 A, 440 mA) 1000 V FAST Fuse Fluke Specified Part Only |
Display (LCD) | Update Rate: 4/sec Volts, Amps, Ohms: 6000 Counts Frequency: 10,000 Counts Capacitance: 1,000 Counts |
Battery Type | 3 x AA Alkaline Batteries, NEDA 15A IEC LR6 |
Battery Life | 250 Hours Minimum |
RF Communications | 2.4 GHZ ISM Band |
RF Communication Range | Open Air, Unobstructed: Up to 20m Obstructed, Sheetrock Wall: Up to 6.5m Obstructed, Concrete Wall, or Steel Electrical Enclosure: Up to 3.5m |
Temperature | Operating: -10 to 50°C Storage: -40 to 60°C |
Temperature Coefficient | 0.1 x (Specified Accuracy)/°C (<18°C or >28°C) |
Relative Humidity | 0 to 90% (0 to 35°C) 0 to 75% (35 to 40°C) 0 to 45% (40 to 50°C) |
Altitude | Operating: 2,000 m Storage: 12,000 m |
Electromagnetic Compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety Compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd Edition CAN/CSA-C22.2 No 61010-1-12: 3rd Edition UL 61010-1: 3rd Edition IEC/EN 61010-1:2010 |
Certifications | CSA, FCC, CE |
Ingress Protection (IP) Rating | IP54 |
Pollution Degree | 2 |
Dimensions | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14") |
Weight | 340 g (12 oz) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.