Megger 1014430 OffersPinpointing means precisely locating faults in the cable sheath. These faults cause the measuring current to flow into the ground. When the measuring current exits the cable at the fault point, the current builds a voltage gradient which can be measured by earth rods and earth fault locators. The step voltage method accurately locates sheath faults: as it approaches the fault point, the step voltage potential increases. After it passes the fault, the potential decreases with reversed polarity. The change in polarity allows the fault to be located precisely.
The ESG NT2 earth fault locator measures the step voltage potential produced by underground test generators. Other existing underground distortions such as potential equalisation current, DC offset, 16 ²/³ Hz or influences from cathodic protection systems are automatically detected and eliminated. The automatic zero calibration maintains the display calibration continuously at zero.
The ESG NT2 has a high-contrast color display on which the measured step voltage is displayed in two ways: as a bar graph (similar to a conventional pointer instrument), and as a continuous “history-display” which shows both the current process and the last 5 to 6 measurement records. In this way, changes are displayed clearly and continuously.
Features
| Display | High-contrast color TFT, 320 x 240 pixels |
| Detection modes | Standard and power frequency (50/60 Hz) |
| Sensitivity | 5 μV |
| Suppression of disturbances | 50/60 Hz, 16 2/3 Hz, KKS, DC |
| Zero adjustment | Automatically |
| Duty cycle recognition | Automatically |
| Power supply | 6 x LR6 Alkali-Mangan (AA) |
| Operation time | > 20 hours |
| Protection class | IP54 |
| Dimensions receiver (H x B x D) | 2.56 x 8.86 x 3.94" (65 x 225 x 100 mm) |
| Weight Receiver | 1.98 lbs (0.9 kg) (including batteries) |
| Length Earth Rods | 39.37" (1 m) (divisible and isolated) |
| Weight Earth Rods | 1.76 lbs (0.8 kg) each |
| Length Test Leads | 78.74" (2 m) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.