Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V is available at EquipTestPro.com with fast shipping and great prices.
The industrial multi tester is a versatile instrument with a complete suite of insulation and low resistance testing capabilities, plus continuity, inductance, capacitance, voltage, and temperature measurements. Additionally, the instrument can test insulation resistance from 100 Ω up to 200 GΩ, with test voltages of 50, 250, 500 V, 1 kV, and selectable variable voltage. The instrument includes a guard terminal, and supports several diagnostic insulation resistance functions including spot reading, polarisation index ratio, and timed insulation testing.
The multi tester comes with a unique four-wire digital low resistance function that includes a stable power supply that can deliver 200 mA in long circuits with a resistance range from 1 mΩ up to 10 Ω. This unit offers different test modes selectable through a soft keypad, including bidirectional, unidirectional, automatic, and continuous. The rotary switch and soft keypads are easy to operate, with or without gloved hands, and the instrument’s full colour graphic display makes it easy to select functions and take readings.
The unit also has a supplied thermocouple (CAT III to 600 V) that enables you to test temperature and insulation resistance compensation. What’s more, the LRC function allows the IMT100 to automatically determine if the main element of the load is inductive, capacitive, or resistive, and displays the result on screen. It also gives you the ability to select each function and frequency of 120 to 1000 Hz.
Features
Applications
| Insulation Resistance | Volts accuracy: 50 V: 10 GΩ ±2% ±2 digits ±4% per GΩ100 V: 20 GΩ ±2% ±2 digits ±2% per GΩ250 V: 50 GΩ ±2% ±2 digits ±0.8% per GΩ500 V: 100 GΩ ±2% ±2 digits ±0.4% per GΩ1000 V: 200 GΩ ±2% ±2 digits ±0.2% per GΩ |
| Polarisation Index (PI) | 10 minutes/1 minute ratio |
| Dielectric Absorption Ratio (DAR) | User configurable 15 or 30 seconds t1 start time with t2 fixed at 60 seconds |
| Guard Terminal Performance | <5% error at 500 kΩ parallel circuit resistance with 100 MΩ loadResolution: 0.1 kΩ |
| Short Circuit/Charge Current | 2 mA 0% -50% (IEC61557-2) |
| Terminal Voltage Accuracy | 0% 2% ±2 V |
| Test Current | 1 mA at minimum pass value of insulation to a maximum of 2 mA |
| Operation Range | 0.1 MΩ to 1 GΩ (IEC61557-2) |
| Leakage Current Display | 0.1 uA resolution 10% (±3 digits) |
| Voltage Display | ±3% ±2 digits ±0.5% of rated voltage |
| Continuity | Measurement: 0.01 Ω to 1 MΩAccuracy: ±3% ±2 digits (0 to 99.9 Ω)±5% ±2 digits (100 Ω to 500 kΩ)Test current: 200 mA (0 mA 20 mA) (0.01 to 4 Ω)Polarity: Single or dual (factory default)Lead resistance: Null up to 10 ΩSelectable current limit: 20 mA and 200 mA |
| Capacitance | Range: 0.1 nF to 1 mFAccuracy: ±5% ±2 digits (1 to 10 μF) |
| Voltmeter | Range: DC: 0 to 1000 VAC: 10 mV to 1000 VTRMS sinusoidal (15 to 400 Hz)Accuracy: DC: ±2% ±2 digits (0 to 1000 V)AC: ±2% ±2 digits (10 mV to 1000 V TRMS)Frequency range: 15 to 400 Hz (50 mV to 1000 V)Frequency resolution: 0.1 HzFrequency accuracy: ±0.5% ±1 digitDiode test accuracy: ±2% ±2 digitsDisplay range: 0 to 3 V |
| Temperature Measurement and Compensation | Thermocouple: Type T (Type K and Type J)Thermocouple range: 4 to 392°F (-20 to 200°C)Instrument range: 4 to 1832°F (-20 to 1000°C)Instrument resolution: 0.18°F (0.1°C)Instrument accuracy: ±1.8°F ±20 digits (±1°C ±20 digits) (Basic accuracy stated assumes forward and reverse measurements) |
| DlRO Four Wire Kelvin Low Resistance | Test current: 200 mA DCRange: 1 mΩ to 10 ΩResolution: 0.01 mΩAccuracy: ±0.25% rdg. ±10 digits, accuracy stated includes forward and reverse measurements |
| Inductance | Instrument accuracy:Range: 1 HAccuracy: ±(0.7% +(Lx/10000)% +5 digits)Test frequency: 1 kHzRange: 200 mHAccuracy: ±(1% +(Lx/10000)% +5 digits)Test frequency: 120 HzAccuracy: ±(0.7% +(Lx/10000)% +5 digits)Test frequency: 1 kHzRange: 20 mHAccuracy: ±(2% +(Lx/10000) % +5 digits)Test frequency: 120 HzAccuracy: ±(1.2% +(Lx/10000)% +5 digits)Test frequency: 1 kHzRange: 2 mHAccuracy: ±(2% +(Lx/10000)% +5 digits)Test frequency: 1 kHz only |
| Results Storage | Storage capacity: 256 test results (date/time stamped)Data download: USB Type A (USB mass storage device) |
| Display | Full LCD colour screen with user configurable backlight |
| Fuse | x2 500 mA (FF) 1000 V 1.26 x 0.24" (32 x 6 mm) ceramic fuse, high break capacity HBC, 30 kA minimum. Glass fuses must not be installed |
| Language | English, french, german and spanish |
| Power | Battery: 6 x IEC LR6 1.5 V Alkaline (AA), IEC FR6 1.5 V Lithium (LiFeS2), IEC HR6 1.2 V NiMH (rechargeable option)Battery life: 10 motors per (complete suite of tests at 100 V into 100 MO)Battery charging: Mains battery charger kitIEC61557-2 - test cycle, 1200 insulation tests with duty cycle of 5 seconds testing on 25 seconds standby at 500 V into 0.5 MOIEC61557-4 test cycle, 1200 continuity tests with duty cycle of 5 seconds testing on 25 standby on 1 Ω resistance |
| Safety | Protection: IEC61010-1 CAT III 600 VIP rating: IP54EMC: Industrial IEC61326 |
| Environmental Conditions | Operating temperature range: 14 to 122°F (-10 to 50°C)Storage temperature range: -13 to 122°F (-25 to 50°C)Humidity: 90% RH at 104°F (40°C) maximumCalibration temperature: 68°F (20°C)Maximum altitude: 9843' (3000 m)Temperature coefficient: <0.1% per °F and °C up to 1 GΩ |
| Dimensions | 8.98 x 4.1 x 2.95" (228 x 105 x 75 mm) |
| Weight | 2.02 lbs (0.93 kg) |
Shop EquipTestPro.com for the best deals on Megger IMT100 Industrial True RMS Multi Tester, ±2%, 1000 V. Fast shipping, competitive pricing, and expert support. Visit equiptestpro.com today!
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.