The Megger MIT310-EN 250/500/1000 V Insulation and Continuity Tester with Voltmeter Function feature the popular Megger digital/analog display.
The complete range of the MIT Series provides indication of insulation resistance up to 999Mohms, 200mA continuity testing, and a fast-reacting continuity buzzer.
MEGGER INSULATION TESTERS COMBINE SAFETY WITH DURABILITY
Developed, after extensive customer research, specifically to meet the needs of today's electrical contractors, the new MIT300 range of insulation and continuity testers from Megger is not only durable and easy to use, but also incorporates a comprehensive set of Features: designed to ensure operator safety, even under conditions of accidental misuse.
The range includes four models, ensuring an exact match for the needs of every user, all of which offer automatic discharge of the circuit after testing, audible and visual warning if the test probes are applied to a live circuit, and a test inhibit feature which operates automatically under live circuit conditions. The units also conform fully to IEC 61010-1 for use in Category III 600V applications, and provide all of the facilities needed to meet insulation testing requirements relating to the current edition of the IEE Wiring Regulations.
In line with other products in Megger's comprehensive new contractor range, MIT300 insulation testers feature rugged construction, with an impact-resistant rubber-overmoulded case, and innovative circuitry which guarantees high accuracy combined with stability of calibration.
All instruments in the new range provide indication of insulation resistance up to 999Mohms, 200mA continuity testing, a fast-reacting continuity buzzer, and facilities for nulling the resistance of the test leads. The entry-level MIT300 insulation test voltages of 250V and 500V, while the remaining models allow testing at 250V, 500V and 1,000V.
In addition to the basic Features:, the mid-range MIT310 adds a default voltmeter function, while the MIT320 supplements these facilities with an a backlit display, illuminated range panel, insulation limit alarm, resistance measurement, and an adjustable threshold for the continuity buzzer. The MEGIT320 is also supplied with a switched test probe to speed hands free testing.
An illuminated switched test probe is available as an optional extra for use with the MIT320. The MIT310, and MIT320 testers incorporate dual solid-state displays which simultaneously show the test results numerically, and in the form of a moving-arc bar graph that accurately simulates the operation of an analogue meter.
For users who prefer a true analogue device, however, Megger is offering the MIT310A which has Features: similar to those of the MIT310, but with a conventional moving-coil meter movement in place of the digital display.
Features:
| Nominal Insulation Test Voltage | 500 V, 250 V DC |
| Measuring Range | All Instruments, 10 k½ to 999 M½ on all ranges |
| Short Circuit Current | 1.5 mA nominal |
| Test Current on Load | 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364) |
| Accuracy (at 20°C) | ±3%, ±2 digits |
| Continuity Range | 0,01 ½ - 99,9 ½ (0 -50 ½ on analogue scale) |
| Open Circuit Voltage | 5 V ±1 V |
| Short Circuit Current | 200 - 215 mA |
| Terminal Accuracy | ±3% ±2 digits |
| Zero Offset Adjust | 0 - 9 ½ |
| Continuity Buzzer | Operates at <5 ½ Response time <20 ms |
| Voltage Range | 0 to 600 V AC. (50/60 Hz) or DC. |
| Voltage Accuracy | DC or AC (50/60 Hz) ±1%, ±2 digits |
| Temperature Coefficient | <0.1% per °C on all ranges. |
| Default Voltmeter | Beeps and flash V on the display (all modes except off) |
| Test Inhibit | If more than 50 volts is detected, testing will be inhibited. |
| Operating Temperature | -10 to 60°C |
| Operating Humidity | 93% R.H. at 40°C max. |
| Storage Temperature | -25 to 70°C |
| Test Result Storage | 1000 results |
| Job Number | 255 locations |
| Distribution Board no. | 99 locations |
| Circuits | 99 locations |
| Phases | P1, P2, P3 |
| Last recorded result may be recalled to the display. All data can be downloaded to a PC using Download Manager (supplied) or Megger Powersuite Professional of Windows software | |
| Communications | USB interface |
| Environmental Protection | IP54 |
| Fuses | Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. Display shows if fuse is ruptured. |
| Safety | Meets the requirements of IEC61010-1 Cat III 600 V phase to earth. |
| Automatic discharge | After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored. |
| Battery | 8 x 1.5 V cells IEC LR6 type (AA alkaline). Rechargeable NiCd or NiMH cells may be used. Battery condition is constantly shown on the display as a four-section bargraph. |
| Battery Life | 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries. Weight |
| All Units | 980 gms |
| Dimensions | All units: 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) |
| E.M.C. | In accordance with IEC61326 including amendment No.1 |
| Nominal Insulation Test Voltage | 500 V, 250 V DC |
| Measuring Range | All Instruments, 10 k½ to 999 M½ on all ranges |
| Short Circuit Current | 1.5 mA nominal |
| Test Current on Load | 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364) |
| Accuracy (at 20°C) | ±3%, ±2 digits |
| Continuity Range | 0,01 ½ - 99,9 ½ (0 -50 ½ on analogue scale) |
| Open Circuit Voltage | 5 V ±1 V |
| Short Circuit Current | 200 - 215 mA |
| Terminal Accuracy | ±3% ±2 digits |
| Zero Offset Adjust | 0 - 9 ½ |
| Continuity Buzzer | Operates at <5 ½ Response time <20 ms |
| Voltage Range | 0 to 600 V AC. (50/60 Hz) or DC. |
| Voltage Accuracy | DC or AC (50/60 Hz) ±1%, ±2 digits |
| Temperature Coefficient | <0.1% per °C on all ranges. |
| Default Voltmeter | Beeps and flash V on the display (all modes except off) |
| Test Inhibit | If more than 50 volts is detected, testing will be inhibited. |
| Operating Temperature | -10 to 60°C |
| Operating Humidity | 93% R.H. at 40°C max. |
| Storage Temperature | -25 to 70°C |
| Test Result Storage | 1000 results |
| Job Number | 255 locations |
| Distribution Board no. | 99 locations |
| Circuits | 99 locations |
| Phases | P1, P2, P3 |
| Last recorded result may be recalled to the display. All data can be downloaded to a PC using Download Manager (supplied) or Megger Powersuite Professional of Windows software | |
| Communications | USB interface |
| Environmental Protection | IP54 |
| Fuses | Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. Display shows if fuse is ruptured. |
| Safety | Meets the requirements of IEC61010-1 Cat III 600 V phase to earth. |
| Automatic discharge | After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored. |
| Battery | 8 x 1.5 V cells IEC LR6 type (AA alkaline). Rechargeable NiCd or NiMH cells may be used. Battery condition is constantly shown on the display as a four-section bargraph. |
| Battery Life | 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries. Weight |
| All Units | 980 gms |
| Dimensions | All units: 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) |
| E.M.C. | In accordance with IEC61326 including amendment No.1 |
| Nominal Insulation Test Voltage | 500 V, 250 V DC |
| Measuring Range | All Instruments, 10 k½ to 999 M½ on all ranges |
| Short Circuit Current | 1.5 mA nominal |
| Test Current on Load | 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364) |
| Accuracy (at 20°C) | ±3%, ±2 digits |
| Continuity Range | 0,01 ½ - 99,9 ½ (0 -50 ½ on analogue scale) |
| Open Circuit Voltage | 5 V ±1 V |
| Short Circuit Current | 200 - 215 mA |
| Terminal Accuracy | ±3% ±2 digits |
| Zero Offset Adjust | 0 - 9 ½ |
| Continuity Buzzer | Operates at <5 ½ Response time <20 ms |
| Voltage Range | 0 to 600 V AC. (50/60 Hz) or DC. |
| Voltage Accuracy | DC or AC (50/60 Hz) ±1%, ±2 digits |
| Temperature Coefficient | <0.1% per °C on all ranges. |
| Default Voltmeter | Beeps and flash V on the display (all modes except off) |
| Test Inhibit | If more than 50 volts is detected, testing will be inhibited. |
| Operating Temperature | -10 to 60°C |
| Operating Humidity | 93% R.H. at 40°C max. |
| Storage Temperature | -25 to 70°C |
| Test Result Storage | 1000 results |
| Job Number | 255 locations |
| Distribution Board no. | 99 locations |
| Circuits | 99 locations |
| Phases | P1, P2, P3 |
| Last recorded result may be recalled to the display. All data can be downloaded to a PC using Download Manager (supplied) or Megger Powersuite Professional of Windows software | |
| Communications | USB interface |
| Environmental Protection | IP54 |
| Fuses | Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. Display shows if fuse is ruptured. |
| Safety | Meets the requirements of IEC61010-1 Cat III 600 V phase to earth. |
| Automatic discharge | After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored. |
| Battery | 8 x 1.5 V cells IEC LR6 type (AA alkaline). Rechargeable NiCd or NiMH cells may be used. Battery condition is constantly shown on the display as a four-section bargraph. |
| Battery Life | 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries. Weight |
| All Units | 980 gms |
| Dimensions | All units: 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) |
| E.M.C. | In accordance with IEC61326 including amendment No.1 |
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.