Features

  • Delivers up to 240 A to measure resistance of high-current links
  • DualGround technology ensures grounding of test object for safe workflow
  • Auto range from 1 microohm to 1000 milliohms
  • Ultra capacitor technology allows for high current generation
  • Stores up to 190 test results and transfers test data to PC via Bluetooth
  • Supplied with Kelvin clamps for carrying out 4-wire Kelvin test
  • Handheld and portable, weighing only 2.2 lbs (1 kg)
  • Battery powered and rechargeable
  • Complies with IEEE and IEC standards

Applications

  • Circuit breaking testing
  • Testing of bus-bar
  • Switches
  • Disconnecting devices
  • Safety ground connections
  • Welding points
  • Fuses
  • Cables

Both Sides Grounded

Within electrical power utilities, switchgear owners and service companies, there is an increased emphasis on efficiency of operations, maintenance and service levels. There is an increased emphasis on health, safety, and environmental compliance. Experience has also shown demands for shorter time periods for testing, while the switchgear is less and less available to be taken out of service.

Many utilities require safety grounds to remain in place during station outages, therefore, the MOM2 was designed with this field safety constraint in mind. DualGround means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment.

Instrument Front View

  • 1. Current output terminal (-)
  • 2. Current output terminal (+)
  • 3. Display
  • 4. Ground (earth) terminal
  • 5. Keys for navigation and to make settings in the display
  • 6. TEST-button
  • 7. Stand-by/Wake up (Press shortly to toggle)
  • 8. Clear log (Press and hold for 5 seconds)
  • 9. Function selector
  • 10. Connector for the voltage (–) sense lead
  • 11. Connector for the voltage sense (+) lead and the trig function
  • 12. Connector for the battery charger
  • 13. Battery charger indicator

The Kelvin probes (included in BD-59090) are used for a 4-wire Kelvin test. This is a way of measuring continuity resistances ensuring all contact and lead resistances are compensated for, allowing a much greater accuracy in measurements. Each Kelvin probe assembly has two probe tips: one tip is for the current generated; the other will measure the very small voltage present.

The Kelvin clamps (included in BD-59092) use the same principle.

Equipment and methods that supports DualGround™ testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy work?ow with both sides grounded throughout the test.??

Megger MOM2 Specifications

Application Field For use in high-voltage substations and industrial environments.
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Recharge Time <12h
Battery Charge Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life =10 years
Audible Feedback Different Buzzer Sounds
User Presets 3
Field Calibraion Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only

Megger MOM2 Specifications

Application Field For use in high-voltage substations and industrial environments.
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Recharge Time <12h
Battery Charge Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life =10 years
Audible Feedback Different Buzzer Sounds
User Presets 3
Field Calibraion Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only

Megger MOM2 Specifications

Application Field For use in high-voltage substations and industrial environments.
Relative Humidity %RH 5%-95%, non condensing
Pollution Degree 2
Shock IEC 60068-2-27
Vibration Vibration IEC 60068-2-6
Transport ISTA 2A
Battery Power Five AA (HR6) 2700 mAh NiMH cells
Recharge Time <12h
Battery Charge Mains Voltage 100 - 250 V AC, 50 / 60 Hz
Power Consumption 60 W
Protection Against wrong battery type, low/high temperature
Real Time Clock Battery Life =10 years
Audible Feedback Different Buzzer Sounds
User Presets 3
Field Calibraion Yes
Encapsulation IP54
Dimensions 217 H x 92 B x 72 D mm
Weight 1.0 kg (2.2 lbs) instrument only
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns