Guaranteed Fitment
Always the correct part
have questions?
Always the correct part
We know our products
Fast & Reliable
MPAC208 Acoustic Imaging Camera
The MPAC208 is a professional-grade acoustic imaging camera designed for fast, accurate detection of ultrasonic sound sources across industrial environments. It helps maintenance teams identify gas leaks, mechanical deterioration, and partial discharge (PD) in high-voltage electrical systems, without needing to interrupt operations.
At its core is a 208 channel MEMS (micro-electromechanical system) microphone array offering sensitivity across 2 kHz to 100 kHz, enabling the MPAC208 to detect even very small leaks and subtle ultrasonic patterns.
The acoustic data is fused with a 13 MP optical camera and displayed on an 8-inch capacitive touchscreen, presenting clear, real-time visual overlays that make sound sources immediately visible.
The MPAC208-IECEx camera provides all the features seen in the standard MPAC208 but is certified for use in Class 2 explosive atmospheres.
Features
MPAC-V Verifier/Ultrasound Generator
The Megger Professional Acoustic Camera Verifier, MPAC-V has button controls to power on/off the MPAC-V, play/ pause an audio file, increase/decrease the volume and switch between the .wav audio files, pre-loaded onto the included MicroSD/TF card.
Key is the inclusion of a Verification sound file that automatically runs through the pre-set frequency bands that mirror the bands selected by the MPAC cameras when running in verification mode, automating the verification process.
In addition, sound files to replicate common partial discharge, using either 50 Hz or 60 Hz as the fundamental, help prove the MPAC cameras detection processor.
The MPAC-V supports a maximum signal output sampling rate of 96 kHz 24 bit, with a rated frequency range from 20 kHz to 48 kHz.
The product features a lightweight, sturdy and durable all-aluminium alloy case and can be powered by either the supplied USB-C 5 V power adaptor or four AA batteries.
MPAC-TM640 Thermal Camera Module
The MPAC-TM640 includes a professional 640 x 512 thermal sensor. This unit is capable of generating high-resolution thermal images and will capture all the temperature data across the image. Through the MPAC208 user interface, relevant parameters can be set to improve the accuracy of the readings, as well as recording vital detail on the asset being measured. A x6 digital zoom is also available to aid pinpointing of issues.
The Thermal Modules are connected to the MPAC208 using a simple, keyed, USB-C port at the top of the camera. The MPAC firmware already supports the use of both modules, so no further set-up is required.
All thermal images and videos captured whilst using the MPAC-TM modules can be imported into the Analyst software, along with the acoustic data, for further analysis and detailed report generation.
Applications
| MPAC208 Acoustic Imaging Camera | |
| Camera | Resolution: 13 MPCamera focal length: 4.3 mm (0.17")Nominal frame rate: 25 fpsField of View (FOV): Horizontal x Vertical: 66 x 52°LED light: 4 ultra-bright LEDs |
| Display | Resolution: 1920 × 1200Size: 8 inchesBrightness: 700 nitsTouchscreen: Capacitive touch screenZoom: 6× digital zoomStandard palettes: Grayscale, Ironbow, Rainbow |
| Communication and Storage | Storage:Internal: 64 GBExternal: 64 GB external microSD cardFormat:Image: JPGAudio: WAVVideo:Format: mp4Length: Up to 10 minutesDigital export: microSD (TF) card / Wi-Fi / USB-C flash driveData transfer: Wi-Fi, USB-C flash drive, Bluetooth®, USB-C cable, microSD (TF) card |
| Hardware Ports | USB-C: 1: USB 3.0 for charging, HDMI, data export2: USB 2.0, USB sensor, thermal module3.5 mm audio jack: Headset outputTF / microSD card slot: 64 GB card suppliedAnalog input: 4-channel external analog sensor |
| Safety | General safety: IEC 61010-1Electromagnetic Compatibility (EMC) – International: IEC 61326-1: PortableElectromagnetic Environment IEC 61326-2-2CISPR 11: Group 1, Class AVibration: 2 g, IEC 60068-2-6Shock: 25 g, IEC 60068-2-27Drop test: 47" (1.2 m) |
| Software | Report types: Gas/Electricity, ISO 50001-compliantAnalysis: Waveform, spectrum, spectrogram, leakage assessment, PRPD type, PRPD spectrum. Thermal image analysis (with optional thermal module MPAC-TM). |
| Battery | Type: Li-ion smart battery with charge indicatorCapacity: 6600 mAh, 7.2 V rechargeable Li-ionLife: 5 hours under full load stateCharge time:USB Type-C port: 2.15 hoursCharging cradle: 1.15 hours |
| Environmental Conditions | Operating Temperature: -4 to 122°F (-20 to 50°C)Relative Humidity: 10 to 95% (no condensation)Storage Temperature: -4 to 158°F (-20 to 70°C)Charging Temperature: 50 to 113°F (10 to 45°C)IP rating: IP54Restriction of Hazardous Substances (RoHS) Compliant: Yes |
| Bluetooth | BT 5.2 |
| Supported Languages | English, Dutch, French, Simplified Chinese, German, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Thai, Arabic, Macedonian, Romanian, Bulgarian |
| Dimensions | 10.6 × 7.5 × 2" (270 × 190 × 51 mm) |
| Weight | 3 lbs (1.4 kg) |
| MPAC-V Verifier/Ultrasound Generator | |
| Acoustic Specifications | Sampling rate: 96 kHzFrequency range: 20 to 48 kHzOperating frequency: 25 kHz ± 5 kHzSupported file type: .wav |
| Power Supply | Port: USB-CRated:Voltage: 5 V (DC)Current: 0.5 ABattery type: AA (Alkaline or Ni-Cad batteries are recommended: 4 required) |
| Tripod Mounting Point | ¼" thread |
| Screen | LCD – 2.8" |
| Resolution | 320 x 240 |
| Environmental Conditions | Operating: -4 to 140°F (-20 to 60°C), 10 to 95%Storage: -4 to 158°F (-20 to 70°C), 10 to 95% |
| Certification | CE-EMC, CE-RoHS |
| Storage Size | Maximum 64 GB MicroSD card |
| Dimensions | 6.81 x 3.15 x 1.38" (173 x 80 x 35 mm) |
| Weight | 1.32 lbs (600 g) |
| MPAC-TM640 Thermal Camera Module | |
| Imaging and Optics | Detector type: 8 to 14 μmInfrared resolution: 640*512 at 12 μmNETD: 60 mK at 77°F f#1.0 (25°C)Frame rate: 25 HzFocal length: 0.5" (13 mm)Field of View: 32.9° * 26.6°IFOV: 0.923 mradMinimum object distance: 5.5" (0.14 m)D:S: 90:1Focusing mode: ManualDigital zoom: 1x - 6xTemperature range: -4 to 248°F / 248 to 1022°F (-20 to 120°C / 120 to 550°C) |
| Measurement and Analysis | Measurement accuracy: ±3% (±3% of the range, take the maximum value)Parameter settings: Temperature scale, Temperature unit, Distance, Emissivity, Thermal correction, Ambient temperature, Reflection, Humidity |
| Image Display | Thermal palette: White-hot, Black-hot, Ironbow, HC Rainbow, Rainbow, Grayscale |
| Power | Power: DC 5 V, 0.05 APort: USB-C |
| Environmental Conditions | Operating temperature: -4 to 122°F (-20C to 50°C)IP rating: IP53Drop test: 47" (1.2 m)Certification: CE, RoHS |
| Material | Aluminium |
| Dimensions | 1.38 x 1.97 x 1.65" (35 x 50 x 42 mm) |
| Weight | 0.13 lbs (60 g) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)