Megger MPQ1000SILVERKIT Handheld Power Quality Analyzer, Silver Kit

No reviews yet Write a Review
$11,291.73
SKU:
MPQ1000SILVERKIT
Condition:
New
Availability:
In Stock
5 customers are viewing this product

Megger MPQ1000SILVERKIT Handheld Power Quality Analyzer, Silver Kit

$11,291.73

Megger MPQ1000SILVERKIT

The advanced PQ recording and analysis the MPQ-1000 coupled with its simplicity makes the analyzer the ideal unit to perform power quality studies, energy audits, load studies, troubleshoot industrial and commercial issues, lighting issues, motor start up, solar panel effects, reactive energy analysis and more. The analyzers scope mode and DMM mode allows the user to perform troubleshooting on the spot as well as performing extended recordings.

The auto CT identification eliminates potential errors due to wrong CT range settings. Simple connection with a push of a button and the analyzer will automatically identify the CT and verify it is connected correctly. This means you can be confident you will have the correct data.

The unit will fit into most locations and supports either Wi-Fi or cellular with the use of an off the shelf bridge. A bridge is the opposite of a router. It receives a wireless signal and transmits the signal over a wire. The bridge connects to the Ethernet port on the instrument. The bridge can be bought off the shelf at different stores. The advantage is it can be moved from unit to unit as needed, since it is not internal to the unit. A class A instrument performs its measurements per the requirements of IEC61000-4-30 and IEEE-1159. This provides a measurement accuracy of 0.1% over the given range. Units that comply to this standard ensure their measurements will agree with one another. Instruments that are not class A can have different measurement values. Most revenue meters are now measure class A RMS value. Therefore to get matching data a class A instrument is required. The unit will trend harmonics through the 50th order. The Megger PQ software will analyze the captured waveforms through the 128th order.

Features

  • 32 GB SD card standard allows user to load recordings directly into a PC (with no additional download routine)
  • PQ analysis can be done in the field on the MPQ1000 screen
  • Comes complete with powerful PQ Analysis Software at no additional charge
  • Automatic CT recognition means never having the unit programmed for an incorrect range
  • CTs are powered by the unit so there is no need for additional connections
  • Connection verification ensures the unit is configured correctly and you get the data you need — no wasted recordings
  • On-board data analysis saves time by allowing an immediate examination of data before leaving the site
  • Multiple communication methods (USB, Ethernet, USB stick or SD card) allow for flexible and convenient operation
  • Removable SD card allows for large recording capabilities and simple memory expansion
  • The expanded 1000 V AC range allows for more application; no need for a second unit
  • 1000 V DC measurement allows testing and analysis of renewable applications dismissing the need for additional equipment
  • CATIV @ 600 V assures a safe unit for all applications
  • Full-featured Class A compliant (all parameters) ensures the recording of correct values
  • Smart configuration in the Megger PQ software for quick and easy setup
  • Phase angle stability measurement lets you easily find tricky phasing problems caused by multiple erratic sources. Timed waveform capture allows for the taking of PQ events and periodic waveforms at the same time
  • Easy intuitive menus allow for simple navigation and operation
  • Free software included means no license or dongle required
  • International Standards and Recommendations: IEC61000-4-30, EN50160, IEEE1159, IEEE519

Measured Parameters

  • RMS voltage / current
  • DC voltage
  • DC current (requires dc CT)
  • Phase-to-phase voltage
  • Power parameters (KW, KVAR, KVA, DPF, TPF)
  • Voltage sag/dips and swells
  • Phase angles
  • Current sags/dips and swells
  • Transient down to 1 msec
  • IEC unbalance
  • Frequency
  • Event waveform capture
  • Total harmonic distortion
  • Total demand distortion
  • Harmonics
  • Inter-harmonics
  • Energy parameters (KWH, KVARH, KVAH)
  • Mains signaling
  • Harmonic direction
  • IEC flicker
  • Rapid voltage change
  • Phase angle deviation
  • ANSII unbalance
  • Timed waveform capture

A telecommunications company can save money, improve quality and reliability to periodically monitor their incoming power quality and their energy usage. By owning a simple and easy-to-use Power Quality device, telecom companies can perform their own periodic assessments without the cost of employing outside service companies to perform these tests. The Megger family of Power Quality products the ability, with their one-touch recording, auto-data analysis and unrivaled software.

Applications

  • Compliance testing to any PQ standard
  • Power factor studies
  • Load studies and load balancing
  • Billing verification
  • Substation monitoring
  • Capacitor bank sizing
  • Transformer analysis and de-rating
  • Motor troubleshooting and inrush testing
  • Switchgear and component failure
  • Tripping breakers
  • Equipment tripping offline
  • Dimming/surging lighting
  • Neutral overheating
  • Solar (PV) analysis
  • Utilities troubleshooting
  • Substation Testing
  • Industrial Sites
  • Engineering / Test Firms
  • Commercial Companies

Benefits

  • Auto CT Detection: The unit not only identifies the CT is connected but also identifies the range the selected range of the current clamp. Never make a mistake programming the wrong range.
  • Configuration Verification: Verifies the instrument is connected properly BEFORE the recording begins. This ensures the recorded data is valid. No wasted recordings and No wasted time.
  • On board Data Analysis: Analyze the data in the field on the spot! Saves time by allowing an immediate examination of the data before leaving the site.
  • Scope Mode: Examine real time waveforms, examine real time phase angles with the vector scope, and examine real time harmonics and inter-harmonics. Find PQ problems without performing an extended recording.
  • SD Card / USB Stick Support: Transfer data and setup configurations without the need of a PC. Just remove and replace the SD Card and start a new recording in a different location. Saves time and effort.
  • Timed Waveform Capture: Capture waveforms not only for power quality events but also capture periodic waveforms at the same time. Perform advanced Fourier Analysis of your system!
  • High end FREE PC Software. No license required, no dongle required. Custom configuration wizard, data analysis, harmonic analysis, waveform analysis up to the 128th harmonic, harmonic direction and more.

Megger PQ Firmware for MPQ Series PQ Analyzers

This firmware adds the following functionality to both the MPQ1000 and MPQ2000.

  • Enables the AUTO voltage recognition
  • Allows the changing of CT values in the default setup files
  • This firmware corrects the following bugs in both the MPQ1000 and MPQ2000

Megger MPQ1000SILVERKIT Specifications

Environmental
Operating Temperature -20 to 50°C
Storage Temperature -30 to 60°C
Humidity 95%
General Specifications
Input Power 120/240 V, 50/60 Hz
Battery NiMH battery pack, Discharge time – up to 8 hours, Recharge time – 2 hours
Data Storage External SD card (32GB max)
Communication USB communications, Ethernet communications, USB stick for data and configuration file transfer, SD card for direct data transfer
Case IP54 enclosure
Power Factor Accuracy: ±0.02 + CT error
Dimensions 175 x 250 x 60 mm (6.89 x 9.85 x 2.36")
Weight Standard unit: 1.82 kg (4 lbs)
Voltage Channels 4
Voltage Range 0 to 1000 V AC
0 to 1000 V DC
Voltage Accuracy 0.1% of Reading
Resolution 16 bit
Crest Factor 1.5
Current Channels 4
Current Range 0 to 6000 A (CT Dependent)
Current Accuracy 0.1% of Reading + CT
Resolution 16 bit
Crest Factor 4.0
Sampling Rate 256 samples per cycle RMS. 1 MHz transient sampling rate
Real Time Clock Accuracy ±20 ppm
Class A
Transients 1?sec (±2697 V)
Timed Waveform Capture Allows for the taking of PQ events and periodic waveforms at the same time.
Wireless With Bridge
International Standards and Recommendations IEC61000-4-30, EN50160, IEEE1159, IEEE519
Self-Identifying CT Yes
Config. Verification Yes
On Board Data Analysis Yes
Scope Mode Yes
DMM Mode Yes
RMS & Demand Yes
Dips (Sags) / Swells (V&I) Yes
Harmonics Yes
Inter-Harmonics Yes
Rapid Voltage Change Yes
Mains Signaling Yes
Phase Shift Detection Yes
IEC and ANSI Unbalance Yes
THD/TDD Yes
Motor Start Up Yes

Megger MPQ1000SILVERKIT Specifications

Environmental
Operating Temperature -20 to 50°C
Storage Temperature -30 to 60°C
Humidity 95%
General Specifications
Input Power 120/240 V, 50/60 Hz
Battery NiMH battery pack, Discharge time – up to 8 hours, Recharge time – 2 hours
Data Storage External SD card (32GB max)
Communication USB communications, Ethernet communications, USB stick for data and configuration file transfer, SD card for direct data transfer
Case IP54 enclosure
Power Factor Accuracy: ±0.02 + CT error
Dimensions 175 x 250 x 60 mm (6.89 x 9.85 x 2.36")
Weight Standard unit: 1.82 kg (4 lbs)
Voltage Channels 4
Voltage Range 0 to 1000 V AC
0 to 1000 V DC
Voltage Accuracy 0.1% of Reading
Resolution 16 bit
Crest Factor 1.5
Current Channels 4
Current Range 0 to 6000 A (CT Dependent)
Current Accuracy 0.1% of Reading + CT
Resolution 16 bit
Crest Factor 4.0
Sampling Rate 256 samples per cycle RMS. 1 MHz transient sampling rate
Real Time Clock Accuracy ±20 ppm
Class A
Transients 1?sec (±2697 V)
Timed Waveform Capture Allows for the taking of PQ events and periodic waveforms at the same time.
Wireless With Bridge
International Standards and Recommendations IEC61000-4-30, EN50160, IEEE1159, IEEE519
Self-Identifying CT Yes
Config. Verification Yes
On Board Data Analysis Yes
Scope Mode Yes
DMM Mode Yes
RMS & Demand Yes
Dips (Sags) / Swells (V&I) Yes
Harmonics Yes
Inter-Harmonics Yes
Rapid Voltage Change Yes
Mains Signaling Yes
Phase Shift Detection Yes
IEC and ANSI Unbalance Yes
THD/TDD Yes
Motor Start Up Yes

Megger MPQ1000SILVERKIT Specifications

Environmental
Operating Temperature -20 to 50°C
Storage Temperature -30 to 60°C
Humidity 95%
General Specifications
Input Power 120/240 V, 50/60 Hz
Battery NiMH battery pack, Discharge time – up to 8 hours, Recharge time – 2 hours
Data Storage External SD card (32GB max)
Communication USB communications, Ethernet communications, USB stick for data and configuration file transfer, SD card for direct data transfer
Case IP54 enclosure
Power Factor Accuracy: ±0.02 + CT error
Dimensions 175 x 250 x 60 mm (6.89 x 9.85 x 2.36")
Weight Standard unit: 1.82 kg (4 lbs)
Voltage Channels 4
Voltage Range 0 to 1000 V AC
0 to 1000 V DC
Voltage Accuracy 0.1% of Reading
Resolution 16 bit
Crest Factor 1.5
Current Channels 4
Current Range 0 to 6000 A (CT Dependent)
Current Accuracy 0.1% of Reading + CT
Resolution 16 bit
Crest Factor 4.0
Sampling Rate 256 samples per cycle RMS. 1 MHz transient sampling rate
Real Time Clock Accuracy ±20 ppm
Class A
Transients 1?sec (±2697 V)
Timed Waveform Capture Allows for the taking of PQ events and periodic waveforms at the same time.
Wireless With Bridge
International Standards and Recommendations IEC61000-4-30, EN50160, IEEE1159, IEEE519
Self-Identifying CT Yes
Config. Verification Yes
On Board Data Analysis Yes
Scope Mode Yes
DMM Mode Yes
RMS & Demand Yes
Dips (Sags) / Swells (V&I) Yes
Harmonics Yes
Inter-Harmonics Yes
Rapid Voltage Change Yes
Mains Signaling Yes
Phase Shift Detection Yes
IEC and ANSI Unbalance Yes
THD/TDD Yes
Motor Start Up Yes
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns