null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

RKI 72-5529RK EAGLE Gas Detector for LEL, PPM, O2, CO, H2S, and F2

No reviews yet Write a Review
$3,460.91
SKU:
72-5529RK
Condition:
New
Availability:
In Stock
5 customers are viewing this product

RKI 72-5529RK EAGLE Gas Detector for LEL, PPM, O2, CO, H2S, and F2

$3,460.91

RKI 72-5529RK

Equipped with features that are not available on most competitive units, the EAGLE is a powerful instrument that

Equipped with features that are not available on most competitive units, the gas detector is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO.  Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors.

Unique features include PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges; a methane elimination switch for environmental applications, a long list of super toxic gases and measurable ranges, and dual hydrophobic filters that increases its water resistant performance. The gas detector has a strong internal pump with a low flow auto shut off and alarm, which can draw samples from up to 125' even with the dual hydrophobic filters in place. This allows for quick response and recovery from distant sampling locations. The gas detector will continuously operate for over 30 hours on alkaline batteries or 18 hours on Ni-Cads. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, data logging, continuous operation adapters, remote alarms and strobes, and dilution fittings, just to name a few. 

With its ergonomic design and large glove friendly buttons, the gas detector easy access to controls such as auto-calibration, alarm silence, demand zero, peak hold and a wide variety of other features. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting.

Features

  • Simultaneous detection of up to 6 different gases
  • Over 400 gas monitoring configurations
  • Wide range of toxic gases
  • PPM/LEL hydrocarbon detection
  • Powerful long-life pump up to 125’ range with filters
  • Low flow pump shut off and alarm
  • Methane elimination switch for environmental use
  • Security “Adjustment Lockout Switch”
  • Up to 30 hours of continuous operation
  • Alkaline or Ni-Cad capability
  • Transformer testing version available
  • Data logging option
  • Auto calibration/Single gas calibration
  • Ergonomic RFI/EMI/chemical/weather resistant enclosure
  • Complies with EPA Method 21
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns