Suitable for many applications, this gas detector is ideal for confined spaces and safety monitoring with its Normal Operating mode and leak investigations with its Leak Check mode. Controlled by a microprocessor, this gas detector continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. In addition, this detector features a large LCD that shows all gas readings, battery level, and current time and automatically backlights in alarm conditions.
Features
Buzzer
One solid-state electronic buzzer is located inside the case. Sound exits the case through a hole in the middle front of the case. The buzzer sounds for gas alarms, malfunctions, low battery voltage, and as an indicator during use of the multi-gas detectors many display and adjustment options.
Charging indicator LED
One LED located near the bottom of the instrument lights up green when a power cable is plugged into the instrument's charging/data port. The LED changes to orange as charging begins. When charging is complete, the LED turns green until the instrument is disconnected from power.
Case
This multi-gas detectors sturdy, high-impact plastic case is radio frequency (RF) resistant and suitable for use in many environmental conditions, indoors and out. The case is dust-proof and waterresistant. A clear plastic window on the front of the case allows for LCD viewing.
Flashlight LED
A white LED is visible through a round, raised, frosted lens in the top of the case. This LED can be used to provide extra light, if necessary. The flashlight can be activated in the Display Mode.
Flow chamber
The flow chamber is on the back of this multi-gas detector and is held in place by four Phillips screws. The flow chamber seals to the rubber sensor gasket which seals to the sensor faces inside this multi-gas detector and routes flow from the pump to the sensors and to the exhaust port (on the back of this multi-gas detector's case).
Sensors
This multi-gas detector uses three sensors to monitor combustible gas, oxygen (O2), carbon monoxide (CO), and hydrogen sulfide (H2S) simultaneously. The sensors are located inside this multi-gas detector and are held in their sockets by the sensor retainer and back case. The sensors use different detection principles, described in the following sections.
Combustible gas sensor
The combustible gas sensor (NCR-6309) detects combustible gas in the %LEL range using 2 catalytic elements: A standard element and a poison-resistant element that is resistant to sensor poisons like silicone. The element's electrical resistance changes based on the reaction of gas with oxygen. The change in resistance affects the current flowing through the element. This multi-gas detector's circuitry amplifies the current, converts the current to a gas concentration, and displays the concentration on the LCD. The standard calibration for the combustible gas sensor is to methane, but the sensor will still detect and respond to a variety of combustible gases.
AIR mode
POWER mode
O2/CO/H2S Sensors
The O2, CO, and H2S sensors are electrochemical cells that consist of two precious metal electrodes in a dilute acid electrolyte. A gas permeable membrane covers the sensor face and allows gas to diffuse into the electrolyte. The gas reacts in the sensor and produces a current proportional to the concentration of the target gas. This multi-gas detector's circuitry amplifies the current, converts the current to a gas concentration, and displays the concentration on the LCD.
Inlet filter holder
The filter holder is a clear plastic dome-shaped piece on the top of the case. A male quick connect fitting is located on the inlet filter holder. This is the multi-gas detector's inlet fitting. The filter holder may be removed by turning it counterclockwise and pulling it away from the case. One flat membrane disk hydrophobic filter, a wire mesh disk, and a rubber filter retaining gasket are held in place by the filter holder and are located in the bottom of the case chamber where the filter holder is installed.
USB type-C data/charging port and protective cover
A USB type-C port is located on the bottom of this multi-gas detector, protected by a rubber cover. Pry off this cover when plugging in a USB Type-C cable (for charging or data transfer). A USB Type-C adapter cable can be connected to a computer's USB port to transfer data to this multi-gas detector's Data Logger Management Program.
Battery pack
A lithium ion (Li-ion) battery pack powers this multi-gas detector. At 77°F (25°C), the battery lasts at least 30 hours. The battery icon in the lower left corner of the LCD shows remaining battery life. A low battery warning activates when this multi-gas detector detects a low battery voltage. This multi-gas detector sounds a dead battery alarm when battery voltage is too low for Measuring Mode. The battery pack can be recharged using an AC or DC charger. Use of batteries or battery chargers not specified by RKI Instruments, Inc. will compromise the CSA classification and may void the warranty. (Warning: To prevent ignition of a hazardous atmosphere, batteries must only be charged in an area known to be nonhazardous)
Applications
| Combustible Gas (CH4 or HC) | Detection principle: Catalytic combustionDetection range: 0 to 100% LELResolution: 1% LELAlarm setpoints (user-defined setting):1st alarm: 10% LEL2nd alarm: 25% LEL3rd alarm: 50% LELOVER alarm: 100% LELResponse time (T90): CH4: Within 30 secondsHC: Withing 40 seconds |
| Oxygen (O2) | Detection principle: Electrochemical typeDetection range: 0 to 40 volume %Resolution: 0.1 volume %Alarm setpoints (user-defined setting):L alarm: 19.5% volume %LL alarm: 18 volume %H alarm: 23.5 volume %OVER alarm: 40 volume %Response time (T90): Within 20 seconds |
| Carbon Monoxide (CO) | Detection principle: Electrochemical typeDetection range: 0 to 2000 ppmResolution: 1 ppmAlarm setpoints (user-defined setting):1st alarm: 25 ppm2nd alarm: 50 ppm3rd alarm: 1200 ppmTWA alarm: 25 ppmSTEL alarm: 200 ppmOVER alarm: 2000 ppmResponse time (T90): Within 30 seconds |
| Hydrogen Sulfide (H2S) | Detection principle: Electrochemical typeDetection range: 0 to 200 ppmResolution: 0.1 ppmAlarm setpoints (user-defined setting):1st alarm: 5 ppm2nd alarm: 30 ppm3rd alarm: 100 ppmTWA alarm: 1 ppmSTEL alarm: 5 ppmOVER alarm: 200 ppmResponse time (T90): Within 30 seconds) |
| Sampling Method | Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter |
| Suction Flow Rate | Minimum 0.35 L/min (open flow rate) |
| Gas Alarm | Pattern: Lamp flashing, continuous modulating buzzer sounding, gas concentration display flashing, vibration Reset operation: Self-resetting or latching |
| Fault Alarm | Self-diagnosis: System, clock, or sensor abnormality; battery voltage drop; calibration failure; pump abnormality; low flow ratePattern: Lamp flashing, intermittent buzzer sounding, detail displayReset operation: Self-resetting |
| Display | LCD digital (7-segment + 14-segment + icons) with backlight |
| Individual Operations | Operational status, clock, battery level, peak reading, pump status, calibration notification |
| Sound Pressure | Approximately 90 dB (30 cm) |
| Data Logger Function | Maximum storage capacity: 3600 itemsInterval: 5 minutes (adjustable) |
| Communication Specifications | USB, 2.0 (for data logger) connector: Type-C |
| Continuous Operating Time | Approximately 30 hours (77°F [25°C], fully charged, no alarm, no backlight) |
| Operating Ambient Temperature/Humidity Range | -4 to 122°F (-20 to 50°C) no sudden changes, 0 to 95% RH (no condensation) |
| Power Source | Rechargeable lithium ion battery |
| Protection Level | IP67 equivalent |
| Approvals | Intrinsically safe constructionIECEx (Ex da ia IIC T4 Ga/Ex ia IIC T4 Ga)ATEX (II1G Ex da ia IIC T4 Ga/II1G Ex ia IIC T4 Ga) |
| Certifications | ATEX/IECEx, QPS (pending) |
| Dimensions | 6.8 x 2.5 x 1.9" (173 x 64 x 47 mm) |
| Weight | Approximately 0.62 lbs (9.87 oz) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.