null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

Rki Instruments 72-0010 03 Series O2 Single Gas Monitor

No reviews yet Write a Review
$295.83
SKU:
72-0010
Condition:
New
Availability:
In Stock
5 customers are viewing this product

Rki Instruments 72-0010 03 Series O2 Single Gas Monitor

$295.83
Weighing In At 2.8 Oz, The Pocket-Sized Rki Instruments 03 Series O2 Single Gas Monitor 72-0010 Is The Ultimate In Convenience And Functionality. It Has An Operational Life Of 3000 Continuous Hours On (2) Aaa Size Alkaline Batteries, And Is Impact, Dust, And Water Resistant. This O2 Gas Detector Features Two User-Adjustable Preset Alarms And Is Also Equipped With Visual, Audible, And Vibration Alarms As Standard. The Rki Instruments 03 Series O2 Single Gas Monitor 72-0010 Is The Perfect Device For Even The Most Challenging Environments, Such As: Fire Services. In Areas Of Hazardous Material Petrochemical Mining Tunnels Water And Wastewater Treatment Refineries Utilities Pharmaceuticals Chemical Plants Key Features: Pocket Size 2.1 In. (W) X 2.6 In. (H) X 0.9 In. (D) Lightweight (2.8 Oz.) Data Log From 5 To 300 Hours With Adjustable Intervals Operates 3,000 Hours On Alkaline Batteries Impact, Dust, And Water Resistant (Ip-67) Replaceable Rubber Boot Automatic Backlight Audible / Visual / Vibration Alarms Low Battery Alarm Specifications Of The Rki Instruments 03 Series O2 Single Gas Monitor 72-0010: Oxygen (O2) Detection Principle: Galvanic Cell Detection Range: 0 ¬ 40 Percent Volume Alarm Set Points: Low - 19.5 Percent Volume High - 23.5 Percent Volume Over - 40.0 Percent Volume Alarm Types: Gas Alarms: 1St And 2Nd (User Adjustable), Over Alarm, Stel And Twa Trouble Alarms: Sensor Connection, Low Battery Circuit Failure, And Calibration Range Error Gas Sampling: Diffusion Response Time: T90 In 20 Seconds (Alarms Within 5 Seconds When Exposed To 12 Percent O2) Data Logging: 10 Second Intervals = 5 Hours, 5 Minute Intervals = 150 Hours, 10 Minute Intervals = 300 Hours Accuracy: ± 5 Percent O2 Instrument Records Alarms, Alarm Trends, Gas Readings, Calibration & Bump Test History, Instrument Information And Settings Safety Rating: Atex/Iecex Approved. Csa Classified, ¬š¬¦‚¾¢c/Us¬, As Intrinsically Safe, Class I, Division 1, Groups A, B, C, D (Pending) Display: Digital Lcd, Gas Name & Concentration, Auto Backlighting During Alarm, Operation Icon, Battery Icon Continuous Operation: Alkaline Dry Cell: More Than 3,000 Hours (At 25 Degrees C, No Backlight) Enclosure: Dust And Water Resistant With Ip-67 Rating 2 Year Warranty This Rki O2 Monitor Also Includes: Rubber Protective Boot Alkaline Batteries Alligator Clip Wrist Strap Data Log Software Technical Support The Professionals At Testequipmentusa Are Dedicated To Helping You Find Great Equipment At Competitive Prices. Our Commitment To Excellence Means You Can Measure With Confidence Knowing YouVe Got The Right Tools For The Job. Contact Us Today For More Information On The Rki Instruments 03 Series O2 Single Gas Monitor 72-0010 Or Any Of Our Products.
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns