1-587-566-0049
Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 5 A, DC
3 in stock

Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 5 A, DC

SKU: Acuvim 3-M-5A-P2

$2,576.00

Availability: 3 to 4 Weeks Accuenergy Acuvim 3-M-5A-P2 Offers The Acuvim 3 advanced power quality meters are engineered to provide high-precision power quality metering plus revenue grade, IEC Class 0.1S/ANSI C12.20 Class 0.1 (active energy) four-quadrant power monitoring. With support for synchrophasor applications, it can record real-time power quality disturbances, like dips, swells interruptions, unbalance, flicker, and transients as well

1
Request a Quote
Secure Checkout
Fast Shipping
Authorized Dealer

Availability: 3 to 4 Weeks

Accuenergy Acuvim 3-M-5A-P2 Offers

The Acuvim 3 advanced power quality meters are engineered to provide high-precision power quality metering plus revenue grade, IEC Class 0.1S/ANSI C12.20 Class 0.1 (active energy) four-quadrant power monitoring. With support for synchrophasor applications, it can record real-time power quality disturbances, like dips, swells interruptions, unbalance, flicker, and transients as well as capture critical waveforms triggered by sub-second power quality events. Its enhanced Fast Log capture feature can generate and send reports, providing critical information to mitigate the impact of damaging power quality issues. Compact and robust, this advanced power quality meter features a wide range of flexible communication protocols plus an easy-to-use interface with advanced user management and security.

Features

  • Advanced single-point metering with revenue grade accuracy
  • Fast Log captures instantaneous power quality events and saves a report for future assessment
  • Reduce downtime and prevent unexpected equipment errors with sophisticated power quality metering with event notification via email, digital output, or relay output
  • Two, powerful HMI options: Easy-to-use 7" (17.78 cm) touchscreen interface or advanced, built-in web interface for real-time analysis on the go
  • Compact design for flexible installation and straightforward system or panel integration
  • Recieve instant email notifications to stay informed of system or equipment failures from anywhere
  • IEC 61000-4-30 Class-A Compliant Metering of Split-Second Power Malfunctions
  • IEC 61557-12 Class 0.1 Accuracy Compliant for Voltage/Current RMS
  • IEC 62053-22 Class 0.1s and ANSI C12.20 Class 0.1 Accuracy for Active Energy
  • IEC 62053-24 Class 0.5s Accuracy for Reactive Energy
  • Multi-protocol support: Modbus-RTU, Modbus-TCP/IP, BACnet-IP, DNP3 TCP, IEC 61850, & SNMP
  • PMU (IEEE C37.118) for fast and reliable synchrophasor measurement
  • Waveform Capture detection up to 512 sample/cycle and stored in COMTRADE format
  • Time of Use (TOU) with eight tariff and up to twelve billing periods
  • Fast Log capture with 1 cycle RMS
  • Up to 100 dataloggers with user-selectable logging interval and parameters
  • Data post: HTTP/HTTPs, SFTP, and email

Power quality metering

IEC 61000-4-30 Class-A compliant measurement for:

  • Voltage/Current RMS, updated at 1 cycle with IEC 61557-12 Class 0.1 accuracy
  • Frequency, 1 mHz accuracy, 40 to 70 Hz
  • Voltage/Current harmonics magnitude and angle, up to 127th
  • Voltage/Current unbalance
  • Flicker

Power quality reporting and analysis

Power quality event detection for:

  • Voltage dip/swell/interruption based on 1 cycle RMS
  • Current dip/swell based on 1 cycle RMS
  • Transient overvoltage based on 32 ksps

Power quality event to trigger email notification, or DO/RO

Up to 65,535 power quality event logs in circular buffer

Waveform Capture

  • Triggered by power quality or manually
  • User configurable sample rate up to 512 sample/cycle
  • User configurable duration (pre-trigger + post-trigger) from two cycles to two seconds at 512 sample/cycle
  • COMTRADE format, download from webpage/SFTP, or post via HTTP(s), FTP, SFTP

Fast Log Capture

  • Triggered by power quality or manually
  • Capture with 1 cycle RMS
  • User configurable duration, same as Waveform Capture
  • Fast log report, download from webpage/SFTP, or post via HTTP(s), FTP, SFTP

Reporting

  • EN50160 compliance report
  • IEEE 519 compliance report
  • ITIC (CBEMA) Curve
  • SEMI-F47 Curve

Advanced power and energy metering

IEC 62053-22 Class 0.1S active energy measurements

IEC 62053-24 Class 0.5S reactive energy measurements

Import/export/net/total and Four-Quadrant energy measurements

Time of Use (TOU) support:

  • Up to eight tariff rates
  • Flexible calendar and billing date configuration
  • Record current and up to twelve historic billing periods

Communication protocols

  • Modbus-RTU via RS485
  • Dual ethernet
  • WiFi
  • Modbus-TCP/IP
  • HTTPs Webserver
  • HTTP/HTTPs Post
  • BACnet-IP
  • FTP Post
  • SMTP
  • SNMP
  • SNTP
  • DNP3 over IP
  • IEC 61850
  • PMU

Applications

  • Power quality
  • Data centers
  • Industrial automation
  • Manufacturing facilities
  • Transportation
  • Utilities
  • Healthcare
  • Telecommunications
  • University laboratories

Accuenergy Acuvim 3-M-5A-P2 Specifications

Specifications

General
Voltage Accuracy 0.1% reading, 10 to 400 VLN, 690 VLL
Current Accuracy 0.1% reading:1 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 A
Frequency Accuracy 1 mHz, 40 to 70 Hz
Active Energy Accuracy IEC 62053-22 Class 0.1SANSI C12.20 Class 0.1
Power Quality IEC 6100-4-30 Class A, testing according to IEC 62586-2 (2017)
Safety IEC/UL 61010-1:2010IEC/UL 61010-2-030:2010Overvoltage Category IIIMeasurement Category III
Measurements
Voltage RMS IEC 61557-12 Class 0.1, 10 to 400 VLN, 690 VLL
Current RMS IEC 61557-12 Class 0.11 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 A
Frequency 1 mHz accuracy, 40 to 70 Hz, exceeds requirement of IEC 61557-12 Class 0.02
Power and Power Factor (for each phase and system) Active power: IEC 61557-12 Class 0.1ReActive power: Exceeds requirement of IEC 61557-12 Class 1Apparent power: IEC 61557-12 Class 0.2Power factor: Exceeds requirement of IEC 61557-12 Class 0.5
Fundamental Measurements Line to neutral voltage RMSLine to line voltage RMSLine current RMSActive powerReactive powerApparent powerPower factor
maximumimum/Minimum maximumimum/minimum of RMSPower and power factorsFundamental measurements records with timestamp
Demand Algorithms: Block and rolling windowLog peak demand and peak demand timeCurrent demand for each phase and systemPer phase and system active power demand:Import/export/net/totalFour-quadrantPer phase and system reactive power demand:Import/export/net/totalFour-quadrantPer phase and system apparent power demand:TotalFour-quadrant
Energy (per phase and system) Active energy, IEC 62053-22 Class 0.1S:Import/export/net/totalFour-quadrantReactive energy, IEC 62053-24 Class 0.5S:Import/export/net/totalFour-quadrantPer phase and systemApparent energy, IEC 61557-12 Class 0.2:TotalFour-quadrant
TOU Energy and Demand For system import active energy, import reactive energy, and apparent energy:Up to 8 tariff ratesRecord maximumimum power demand of billing periodRecord current and up to 12 historic billing periods
Power Quality Measurements Positive/negative/zero sequence for current and voltagePhase angle for current and voltageHarmonics magnitude and angle for current and voltage, up to 127thFlicker
Communications
Communication Interfaces 2 x Ethernet ports (100BASE-TX) with IEEE1588 support: RJ45 connector, CAT5/5e/6/6a cable1 Wi-Fi (802.11 b/g/n 2.4 GHz)1 RS485 port: Baud rates of 2400 to 115,200, pluggable screw terminal connector1 USB-C port1 IRIG-B port
Time Synchronization NTPPTPIRIG-B
Serial Port Protocols Modbus RTU
Web Server HTTP/HTTPS
Ethernet Port Protocols IPv4, IPv6, DHCP, DNSModbus TCP, DNP3 TCP, IEC 61850, SNMP, BACnet/IP, PMU (IEEE C37.118)Data post with HTTP(s)/FTP/SFTP/SMPT/SMPT E-mailFile download with HTTP(s)/SFPT
Electrical Characteristics
Power Supply 20 to 60 V DC
AC Voltage Inputs Accuracy range: 10 to 400 VLN, 690 VLLPickup: 5 VOverload: 1500 V AC continuously; 2500 V AC, 50/60 Hz 1 minuteMeasurement category: IIIFrequency range: 40 to 70 Hz (50/60 Hz nominal)
AC Current Inputs Nominal current: 1 or 5 AAccuracy range:1 A nominal: 10 mA to 2 A5 A nominal: 50 mA to 10 APickup:1 A nominal: 0.5 mA5 A nominal: 2.5 mASurge: 20 A continuous, 50 A at 10 second/hour, 500 A at 1 second/hour
Input and Output (meter base) 4 digital inputs:Input voltage range: 20 to 150 V AC/DCInput current (maximum): 2.5 mAStart voltage: 15 VStop voltage: 5 VPulse frequency (maximum): 100 Hz, 50% duty ratio (5ms ON and 5ms OFF)SOE resolution: 2ms1 digital output:Dry contactVoltage range: 30 V DCLoad current: 60 mA (maximum)Output frequency: 50 Hz, 50% duty ratio (20ms ON, 20ms OFF)Isolation voltage: 5000 V AC
I/O Modules (up to 3, sold separately) Digital input:Input voltage range 20 to 160 V AC/DCInput current (maximum) 2 mAStart voltage 15 VStop voltage 5 VPulse frequency (maximum) 100 Hz, 50% duty ratioSOE resolution 2msDigital output (DO) (Photo-MOS):Voltage range 0 to 250 V AC/DCLoad current 100 mA(maximum)Output frequency 25 Hz, 50% duty ratioIsolation voltage 2500 V ACRelay output (RO):Switching voltage (maximum) 250 V AC, 30 V DCLoad current 5 A(R), 2 A(L)Set time 10ms (maximum)Contact resistance 30 mΩ (maximum)Isolation voltage 2500 V ACAnalog output (AO):Output range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional)Accuracy 0.5%Temperature drift 50 ppm/°C typicalIsolation voltage 500 V DCOpen circuit voltage 15 VAnalog input (AI):Input range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (optional)Accuracy 0.2%Temperature drift 50 ppm/°C typicalIsolation voltage 500 V DC
Mechanical Characteristics
Outlines Standard DIN 43700, ANSI C39.1Round or square, 3.6 x 3.6" (92 x 92 mm)
IP Degree of Protection IP 54: panel mount and touchscreen display, frontIP 30: panel mount rear, DIN rail mount, I/O modules
Environmental Conditions
Temperature Operating: -13 to 158°F (-25 to 70°C)Storage: -40 to 158°F (-40 to 70°C)
Pressure Normal
Humidity 5 to 95% RH non-condensing
Altitude 9842.5' (3000 m)
Pollution Degree 2
Location/Mounting Indoor use only
Electromagnetic Compatibility
Immunity to Fast Transients IEC 61000-4-4:Power, input/output, voltage/current circuits: ±4 kV (5 kHz)Communication: ±4 kV (5 kHz)
Immunity to Ring Waves IEC 61000-4-12:Power, input/output, voltage/current circuits: 2.5 kVCommunication: 2.5 kV
Immunity to Electrostatic Discharge IEC 61000-4-2:Contact discharge: ±4 kVAir discharge: ±8 kV
Immunity to Voltage Dips and Interruptions IEC 61000-4-11:70%, 20 ms0%, 100 ms
Immunity to Power Frequency and Magnetic Fields IEC 61000-4-8:100 A/m, 1 minute1000 A/m, 3 seconds
Immunity to Surges IEC 61000-4-5:Power, voltage/current circuits: ±4 kVInput/output: 2 kVCommunication: 2 kV
Immunity to Radiated Fields IEC 61000-4-3:80 to 1000 MHz: 10 V/m1 to 2.7 GHz: 3 V/m2.7 to 6.0 GHz: 1 V/m
Immunity to Conducted Disturbances IEC 61000-4-6:150 kHz to 80 MHz: 10 V
Immunity to Power Frequency Disturbances IEC 61000-4-16:30 V: 1 minute300 V: 1 s
Immunity to Damped Oscillatory Wave IEC 61000-4-18:AC:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)1 kV (differential mode, 10 MHz)DC:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)1 kV (differential mode, 10 MHz)IO:2.5 kV (common mode, 1 MHz)1 kV (differential mode, 1 MHz)
Radiated Emissions CISPR 32 Class B

What's included with the Accuenergy Acuvim 3-M-5A-P2

  • Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 5 A, DC

Accuenergy Acuvim 3 Series Advanced Power Quality Meter with DIN rail mount, 5 A, DC. Great savings PLUS Free Shipping when you order online at EquipTestPro.com.