1-587-566-0049
AEMC 566 TRMS Clamp-On Leakage Current Meter, 6/60/600 mA,  1/10/100 A
2 in stock

AEMC 566 TRMS Clamp-On Leakage Current Meter, 6/60/600 mA, 1/10/100 A

SKU: 566

$414.96

Availability: 2 to 3 Weeks AEMC Instruments 566 Offers Measure up to 60 Arms, V AC and V DC ranges, resistance, and continuity with a buzzer with this clamp-on meter. In addition, users can activate a low-pass filter (LPF) to ignore all currents other than 50/60 Hz, where only the fundamental signal is measured. Features Check for leakage and locate insulation breakdowns on live circuits Measures leakage current down to 0.001 mA with up to 1 μ

1
Request a Quote
Secure Checkout
Fast Shipping
Authorized Dealer

Availability: 2 to 3 Weeks

AEMC Instruments 566 Offers

Measure up to 60 Arms, V AC and V DC ranges, resistance, and continuity with a buzzer with this clamp-on meter. In addition, users can activate a low-pass filter (LPF) to ignore all currents other than 50/60 Hz, where only the fundamental signal is measured.

Features

  • Check for leakage and locate insulation breakdowns on live circuits
  • Measures leakage current down to 0.001 mA with up to 1 μA resolution
  • Measures current up to 60 Arms
  • Measures up to 600 V AC/DC
  • Measures Hz on either V or A inputs
  • Measures resistance and continuity
  • Hold feature freezes value
  • MAX feature keeps track of highest measured in-rush value
  • Zero button ideal for measuring relative values
  • Low pass filter to isolate (50/60) Hz fundamental from harmonics
  • Compatible with VDE 0404
  • Backlight LCD
  • Safety barrier anti-slip guard
  • Backlight button
  • Jaw trigger for jaw opening/closing, assembly Ø0.91" (23 mm)
  • Function select rotary dial
  • ZERO button
  • PEAK/Ω button
  • HOLD/LPF button
  • COM (black) input terminal jack
  • Positive (red) input terminal jack
  • Auto-off indicator
  • Polarity indicator
  • Low battery indicator
  • AC measurement indicator
  • DC measurement indicator
  • Current measurement indicator
  • Voltage measurement indicator
  • Zero indicator
  • Data hold indicator
  • Peak hold indicator
  • Low pass filter indicator
  • Continuity test indicator
  • Measurement unit
  • Resistance measurement indicator
  • Measurement unit

Applications

  • Low AC current measurements

AEMC Instruments 566 Specifications

Specifications

ACmA Current (TRMS, Auto-Ranging) Range: 6 mAResolution: 0.001 mAAccuracy: 1% of reading ±8 cts (50 to 60 Hz) and 2% of reading ±8 cts (60 to 500 Hz)Maximum: 660 mArmsRange: 60 mAResolution: 0.01 mAAccuracy: 1% of reading ±5 cts (50 to 60 Hz) and 2% of reading ±5 cts (60 to 500 Hz)Maximum: 660 mArmsRange: 600 mAResolution: 0.1 mAAccuracy: 1% of reading ±5 cts (50 to 60 Hz) and 2% of reading ±5 cts (60 to 500 Hz)Maximum: 660 mArmsMaximum voltage to ground: 600 VZero correction: Currents smaller than approximately 0.006 mA display as zeroLow pass filter:Range: 6 mA/resolution: 0.001 mA/accuracy: 2% of reading ±8 ctsRange: 6 mA/resolution: 0.01 mA/accuracy: 2% of reading ±5 ctsRange: 6 mA/resolution: 0.1 mA/accuracy: 2% of reading ±5 cts
AC (TRMS, Auto-Ranging) Range: 6 AResolution: 1 mAAccuracy: 1% of reading ±5 cts (50 to 60 Hz) and 2% of reading ±5 cts (60 to 500 Hz)Maximum: 66 ArmsRange: 60 AResolution: 10 mAAccuracy: 1% of reading ±5 cts (50 to 60 Hz) and 2% of reading ±5 cts (60 to 500 Hz)Maximum: 66 ArmsMaximum voltage to ground: 600 VLow pass filter:Range: 6 A, resolution: 0.001 A, accuracy: 2% of reading ±5 ctsRange: 60 A, resolution: 0.01 A, accuracy: 2% of reading ±5 cts
AC Voltage (TRMS) Range: 6 AResolution: 0.01 VAccuracy: 1% of reading ±3 ctsMaximum: 660 V RMSRange: 600 VResolution: 0.1 VAccuracy: 1% of reading ±3 ctsMaximum: 660 V RMSMaximum voltage to ground: 600 VInput impedance: 2 MΩ
DC Voltage Range: 60 VResolution: 0.01 VAccuracy: 1% of reading ±2 ctsMaximum: 660 V RMSRange: 600 VResolution: 0.1 VAccuracy: 1% of reading ±2 ctsMaximum: 660 V RMSInput impedance: 2 MΩ
Resistance Ω Range: 600 ΩResolution: 0.1 ΩAccuracy: 1% of reading ±2 ctsRange: 6 KΩResolution: 0.001 kΩAccuracy: 1% of reading ±2 ctsRange: 60 KΩResolution: 0.01 kΩAccuracy: 1% of reading ±2 ctsRange: 600 KΩResolution: 0.1 kΩAccuracy: 1% of reading ±2 cts
Continuity Buzzer activates <45 Ω (0 to 1) kΩFunction: A-HzResolution 0 to 100 Hz: 0.1 HzResolution 100 Hz to 1 kHz: 1 HzSensitivity: 10 mArms minAccuracy: ±0.5% of reading ±2 ctsFilter: On (50/60) Hz only; Off (full frequency range)Maximum sample rate: 100 msFunction: V-HzResolution 0 to 100 Hz: 0.1 HzResolution 100 Hz to 1 kHz: 1 HzSensitivity: 5 mArms minAccuracy: ±0.5% of reading ±2 ctsFilter: On (50/60) Hz only; Off (full frequency range)Maximum sample rate: 100 ms
Overload OL is displayed
Digital Display 4-digit LCD (6000 maximum)Backlight: LED with backlight; 30 seconds auto-off
Nominal Sample Rate 2 measurements/sec
Power Supply 2 x 1.5 V AAA batteriesBattery life (without buzzer or backlight): 40 hours running AC current and voltage functions and 60 hours running DC voltage and resistance function
Auto Power Off 30 minutes with over-ride
Temperature Operating: 32 to 104°F (0 to 40°C), <80% RH, batteries removedStorage: 14 to 140°F (-10 to 60°C), <80% RH, batteries removed
Altitude 6000' (2000 m)
Safety IEC61557-13: Class 2, ≤30 A/m600 V CAT III Double insulated; Pollution Degree 2CE
Dimensions 8.27 x 3 x 1.32" (210 x 76 x 33.5 mm)Jaw opening size: Ø0.91" (23 mm)
Weight 10.4 oz (296 g) with batteries (meter only)

What's included with the AEMC Instruments 566

  • TRMS Clamp-On Leakage Current Meter
  • 2 x Color-Coded Test Leads (Red/Black)
  • 2 x 1.5 V AAA LR03 Batteries
  • Soft Carrying Case
  • User Manual
  • Two-Year Limited Warranty

AEMC 566 TRMS Clamp-On Leakage Current Meter, 6/60/600 mA, 1/10/100 A. Great savings PLUS Free Shipping when you buy now from EquipTestPro.com.