1-587-566-0049
AEMC 8436 PowerPad Three-Phase Power Quality Analyzer, 2000 V (No Sensors)
2 in stock

AEMC 8436 PowerPad Three-Phase Power Quality Analyzer, 2000 V (No Sensors)

SKU: 8436

$6,575.52

Availability: 2 to 3 Weeks AEMC Instruments 8436 Offers The PowerPad® III Model 8436 is a three- phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV. This three-phase powe

1
Request a Quote
Secure Checkout
Fast Shipping
Authorized Dealer

Availability: 2 to 3 Weeks

AEMC Instruments 8436 Offers

The PowerPad® III Model 8436 is a three- phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.

This three-phase power quality analyzer can record 2 GB of trend data on a memory card. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and >16,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks, or even months. Inrush current can also be captured and stored.

Features

  • Measurement of TRMS voltages up to 1000 Vrms AC/DC for two, three, four or five-wire systems
  • Measurement of TRMS currents up to 10,000 Arms (sensor dependent)
  • 65 μs sample rate
  • Direct measurement of neutral current and voltage
  • Record and display trend data as fast as once per second for one month for up to 25 variables
  • Transient detection on all V and I inputs (up to 210)
  • Selectable PT and CT ratios
  • Inrush current measurement
  • Calculation of crest factors for V and A
  • Calculation of the K-factor for transformers
  • Calculation of short and long term flicker and three-phase voltage unbalance
  • Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic
  • Displays of harmonic sequencing and direction and calculation of overall harmonics
  • Real-time display of phasor diagrams including values and phase angles
  • Measurement of active, reactive and apparent power per phase and their respective sum total
  • Calculation of power factor, displacement power factor and tangent factor
  • Recording, time stamping and characterization of disturbance (swells, sags and interruptions, excedence of power and harmonic thresholds)
  • 2 GB internal trend recording memory; Alarm, snapshot and transient/Inrush memories are separate
  • Measurement of energy kVAh, kvarh and kWh
  • The maximum and minimum RMS measurements are calculated every half-period
  • Includes DataView® software for configuring, real-time display, analysis and report generation

Applications

  • Power quality analysis
  • Electrical diagnostics
  • Energy audits
  • Harmonics measurement
  • Voltage and current measurement
  • Power factor analysis
  • Power system commissioning
  • Utility services
  • Renewable energy systems
  • Transformer analysis

AEMC Instruments 8436 Specifications

Specifications

Sampling Frequency 256 samples/cycle
Data Storage SD card for trend recordingAdditional separate 12.5 MB partitioned memory for snapshots, transient/inrush and alarms
Voltage (TRMS) Phase-to-Phase: 2000 VPhase-to-Neutral: 1000 VVoltage Ratio: up to 500 kV
Current (TRMS) MN Clamp: 0 to 6 A / 120 A or 0 to 240 ASR Clamp: 0 to 1200 AMR Clamp: 0 to 1000 A AC, 0 to 1400 A DCMiniFlex®: 10 to 3000 AAmpFlex®: 10 to 10 kA (1)SL261 Clamp: 50 mA to 100 Aac/dcJ93: 50 to 3500 Aac/dcCurrent Ratio: 10 mA to 50 kA
Frequency (Hz) 40 to 69 Hz
Other Measurements kW, kvar, kVA, PF, DPF, kWh, kvarh, kVAh, K-Factor, Flicker
Harmonics 1st to 50th, Direction, Sequence
Communication Port Optically isolated USB
Inputs 4 Voltage / 4 Current
Sample Rate 256 per Cycle 12.8 kHz at 50 Hz 15.36 kHz at 60 Hz
Vrms (AC + DC) Range: 1000 V P to N 2000 V P to P Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±0.5% reading + 200 mV
Vpk Range: 1414 V Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±3% reading + 2 V
Vrms Half Cycle Range: 1000 V P to N 2000 V P to P Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±0.8% reading + 1 V
Amps (AC + DC) Range: SR193 and MR193 Measurement range: 1 to 1000 A Resolution: 0.1 A Accuracy: ±0.5% reading + 200 mA Range: MN193 5 A Measurement range: 5 mA to 5 A Resolution: 1 mA Accuracy: ±0.5% reading + 2 mA Range: MN193 100 A Measurement range: 100 mA to 100 A Resolution: 10 mA Accuracy: ±0.5% reading + 20 mA
AmpFlex and MiniFlex Range: 100 A Measurement range: 100 mA to 100 A Resolution: 10 mA Accuracy: ±0.5% reading + 30 mA Range: 6500 A Measurement range: 10 to 6500 A Resolution: 0.1 A and 1 A Accuracy: ±0.5% reading + 3 A Range: 10 kA Measurement range: 10 A to 10 kA Resolution: 1 A Accuracy: ±0.5% reading + 3 A
Apk Range: SR193 and MR193 Measurement range: 1 to 1414 A Resolution: 0.1 A Accuracy: ±1% reading + 2 A Range: MN193 5 A Measurement range: 5 mA to 7.017 A Resolution: 1 mA Accuracy: ±1% reading + 20 mA Range: MN193 100 A Measurement range: 100 mA to 141.4 A Resolution: 10 mA Accuracy: ±1% reading + 200 mA
Apk AmpFlex and MiniFlex Range: 100 A Measurement range: 100 mA to 100 A Resolution: 0.1 A Accuracy: ±3% reading + 600mA Range: 6500 A Measurement range: 10 to 6500 A Resolution: 0.1 A and 1 A Accuracy: ±3% reading + 5 A Range: 10 kA Measurement range: 10 A to 10 kA Resolution: 1 A Accuracy: ±3% reading + 100 A
A Half Cycle Range: SR193 and MR193 Measurement range: 1 to 1200 A Resolution: 0.1 A Accuracy: ±1% reading + 10 A Range: MN193 5 A Measurement range: 5 mA to 6 A Resolution: 1 mA Accuracy: ±1% reading + 1mA Range: MN193 100 A Measurement range: 100 mA to 120 A Resolution: 10 mA Accuracy: ±1% reading + 100 mA
Frequency Range: 40 to 70 Hz Resolution: 0.01 Hz Accuracy (typical): ±0.01 Hz
Power Watts (VA, var) P-Q-S Probes: AmpFlex, MiniFlex Range: 10 mW to 10 MW 10 mW to 10 MW Resolution: 4 digits minimum Accuracy (typical): ±1% reading ±1.5% reading
Power Factor (Cos Φ/DPF) Range: -1 to 1 Resolution: 0.001 Accuracy (typical): ±1° for Φ, +5 cts for cos Φ
Energy kWh (kVAh, kvarh) P-Q-S Range: 1 mWh to 9,999,999 MWh (MVAh, Mvarh) Accuracy (typical): ±1% reading
Harmonics Range: DC, 1 to 50
Volts and Amp % Range: f Measurement range: 0.0 to 1500% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts Range: r Measurement range: 0.0 to 100% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts Range: Absolute V Measurement range: 0 to 1000 V Resolution: 0.1 V Accuracy: ±2.5% reading + 1 V Range: Absolute A Measurement range: 0 to 1000 A Resolution: 0.1 A Accuracy: ±2% reading + 1 A Range: THD Measurement range: 0 to 999.9% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts
Phase Angle Range: -179° to 180° Resolution: 1° Accuracy (typical): ±1.5° + 1° × (n/12.5)
Additional Features Also display Energy loss, Flicker, Plt (2H), Pst (10min), Unbalance V% and A%
Display 1/4 VGA (320 x 240) color LCD display with adjustable brightness and contrast
Power Source 9.6 V NiMH rechargeable battery pack (included)110 V to 1000 V DC to 400 HzBattery life: ≥8 hours with display on; ≤35 hours with display off (record mode)
Safety Rating EN 61010, 600 V CAT IV(2), 1000 V CAT III, Pollution Degree 2
Dimensions 10.6 x 9.8 x 7.1" (270 x 250 x 180 mm)
Weight 8.2 lbs (3.7 kg) with batteries

What's included with the AEMC Instruments 8436

  • Three-Phase Power Quality Analyzer
  • 5 x 10' Black Voltage Leads with Alligator Clips
  • 5' (1.5 m) USB Cable
  • 110 V US Power Cord
  • 12 x Color-Coded Input ID Markers
  • High-Voltage Warning/Caution Card
  • NiMH Battery
  • Extra-Large Tool Bag
  • Accessory Pouch
  • USB Drive Containing DataView® Software and User Manual
  • Quick Start Guide

AEMC 8436 PowerPad Three-Phase Power Quality Analyzer, 2000 V (No Sensors). Great savings PLUS Free Shipping when you order today on EquipTestPro.com.