Availability: 4 to 5 Weeks AEMC Instruments JM875 Offers This voltage output enables instruments without current ranges to display or log currents on an AC voltage range. The high quality magnetic core and uniform windings provide for accurate measurements up to 30AAC/300AAC/3000AAC. The “squared” jaw permits multiple conductor or bus bar positioning. Provide excellent TRMS capabilities and reliable signal reproduction. Features Nominal range:

1
Request a Quote
Secure Checkout
Fast Shipping
Authorized Dealer

Availability: 4 to 5 Weeks

AEMC Instruments JM875 Offers

This voltage output enables instruments without current ranges to display or log currents on an AC voltage range. The high quality magnetic core and uniform windings provide for accurate measurements up to 30AAC/300AAC/3000AAC. The "squared" jaw permits multiple conductor or bus bar positioning. Provide excellent TRMS capabilities and reliable signal reproduction.

Features

  • Nominal range: 30A AC, 300A AC, 3000A AC (continuous cycle for the full temperature range)
  • Output: 100mV AC/A AC, 10mV AC/A AC, 1mV AC/A AC
  • Designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges

Applications

  • Electrical utility
  • HVAC/R
  • Industrial maintenance
  • Laboratory
  • Plant maintenance

AEMC Instruments JM875 Specifications

Specifications

Nominal Range 30A, 300A, 3000A
Measurement Range 1 to 3200A
Transformation Ratio Voltage output
Output Signal 100mV AC/A AC (3V at 30A) 90A Peak10mV AC/A AC (3V at 300A) 900A Peak1mV AC/A AC (3V at 3000A) 9000A Peak
Accuracy (30A Range) 1.5A: 2% of Reading ± 10mV (0.5A)6A: 2% of Reading ± 10mV (0.5A)30A: 2% of Reading ± 10mV (0.5A)
Phase Shift (30A Range) 1.5A: 15°6A: 7°30A: 5°
Accuracy (300A Range) 15A: 2% of Reading ± 2mV (0.2mA)60A: 2% of Reading ± 2mV (0.2mA)300A: 2% of Reading ± 2mV (0.2mA)
Phase Shift (300A Range) 15A: 3°60A: 1.5°300A: 1
Accuracy (3000A Range) 150A: 2% of Reading ± 0.5mV600A: 2% of Reading ± 0.5mV3000A: 2% of Reading ± 0.5mV
Phase Shift (3000A Range) 150A: 1.5°600A: 1°3000A: 0.5°
Overload 3200A for 5 min
Frequency Range 30 to 5kHzCurrent derating above 200Hz on the 3000A range
Load Impedance >100kHz
Working/Common Mode Voltage 600V AC