AEMC MN02 Current Transformer with 1% Accuracy, Lead, 1mA/A, 100A
SKU: MN02
Availability: 3 to 4 Weeks AEMC Instruments MN02 Offers This probe has a measurement range up to 100Arms which makes it a perfect tool for measurement with DMMs and recorders. It is compatible with any AC ammeter, multimeter, or other current measurement instrument with an input impedance lower than 10Ω. To achieve the stated accuracy, use the probe with an ammeter having an accuracy of 0.75% or better. Features Small, compact size Measurement
Availability: 3 to 4 Weeks
AEMC Instruments MN02 Offers
This probe has a measurement range up to 100Arms which makes it a perfect tool for measurement with DMMs and recorders. It is compatible with any AC ammeter, multimeter, or other current measurement instrument with an input impedance lower than 10Ω. To achieve the stated accuracy, use the probe with an ammeter having an accuracy of 0.75% or better.
Features
- Small, compact size
- Measurement ranges of 50mA to 100A (1Ω load) 50mA to 90A (10Ω load)
- Jaw opening accommodates conductors up to 0.39" diameter
- Designed for DMMs, loggers, recorders and oscilloscopes
- 48 to 10,000Hz frequency range
- 1mA/A from 1Ω to 10Ω output signals
- Designed to EN61326-1, 300V CAT IV, 600V CAT III safety standard
- Double Insulation
- CE Mark
Applications
- Measuring in breaker panels
- Industrial loads
- HVAC/R
- Residential and commercial sites
- Data logging/recording
- General AC current measurements
AEMC Instruments MN02 Specifications
Specifications
| Range | 100A |
| Maximum Currents | 1 < 150A permanent from 48Hz to 500Hz |
| Measurement Range | 50mA to 100A (1Ω load)50mA to 90A (10Ω load) |
| Accuracy in % | ≤1% Reading ± 0.02A (1Ω load)≤ 1.5% Reading ± 0.01A (10Ω load) |
| Phase Shift | Not specified |
| Output Signal | 1mA/A from 1Ω to 10Ω |
| Load Impedance | ≤10Ω |
| Influence of Temperature | ≤0.2% per 10˚K |
| Influence of Adjacent Conductor | ≤2mA/A at 50Hz |
| Influence of Adjacent Conductor Position in Jaws | ≤0.1% at 50/60Hz |
| Influence of Frequency | ≤2% from 65Hz to 500Hz |
| Maximum Output Voltage (secondary open) | ≤30V |