AEMC MN09 Current Clamp for AC, 100 A to 240 A
SKU: MN09
Availability: 2 to 3 Weeks AEMC Instruments MN09 Offers An ergonomic mini-clamp for facilitating work loads to measure low and medium currents from 0.01 to 240 A AC. Features Measures low and medium currents from 0.01 A to 240 A AC Jaws makes ‘hooking’ onto cables easy, even in areas of restrictive access Jaws can grip conductors up to 20mm in diameter Compatible with all multimeters and testers on the market Can measure currents by means of t
Availability: 2 to 3 Weeks
AEMC Instruments MN09 Offers
An ergonomic mini-clamp for facilitating work loads to measure low and medium currents from 0.01 to 240 A AC.
Features
- Measures low and medium currents from 0.01 A to 240 A AC
- Jaws makes ‘hooking’ onto cables easy, even in areas of restrictive access
- Jaws can grip conductors up to 20mm in diameter
- Compatible with all multimeters and testers on the market
- Can measure currents by means of the DC or AC voltage calibres
Applications
- measurement on current transformer outputs, on oscilloscopes and leakage currents
AEMC Instruments MN09 Specifications
Specifications
| Current Range | 0.5 to 240 A AC |
| Current Transformation | 1000/1 |
| Output Signal | 1 mA AC / A AC (240 mA for 240 A) |
| Accuracy and Phase Shift | |
| Primary Current | 0.5 to 10 A, 10 A to 40 A, 40 to 100 A, 100 to 240 A |
| % Accuracy of Output Signal | ≤ 3% + 0.5 mA, ≤ 2.5% + 0.5 mA, ≤ 2% + 0.5 mA, ≤ 1% + 0.5 mA |
| Phase Shift | Not specified, ≤5°, ≤3°, ≤2.5° |
| Electrical Specifications | |
| Bandwidth | 40 Hz to 10 kHz |
| Crest Factor | 3 for a current of 200 A RMS |
| Maximum Currents | 200 A continuous for a frequency 3 kHz (limitation proportional to the inverse of one third of frequency beyond) |
| Load Impedance | ≤10 ɷ |
| Operating Voltage | 600 VRMS |
| Common Mode Voltage | 600 V category III and pollution degree 2 |
| Influence of Adjacent Conductor | ≤ 15 mA / A at 50 Hz |
| Influence of Conductor Position in Jaws | ≤ 0.5% of output signal at 50/60 Hz |
| Load Influence 0.2 to 10 ɷ | <0.5 % on measurement < 0.5° on phase |
| Influence of Frequency | <3 % of output signal 40 Hz to 1 kHz |
| Influence of Crest Factor | <4 % of output signal for a crest factor of 3 and current 200 of A RMS |
| Mechanical Specifications | |
| Operating Temperature | 14 to 131°F (-10 to 55°C) |
| Storage Temperature | -40 to 158°F (-40 to 70°C) |
| Influence of temperature | ≤ 0.15% of output signal per 10°K |
| Relative Humidity for Operation | 0 to 85% RH decreasing linearly above 95°F (35°C) |
| Influence of Relative Humidity | <0.2 % of output signal from 10 to 85 % RH |
| Operating Altitude | 0 to 2000 m |
| Maximum Jaw Opening | 20 mm |
| Clamping Capacity | Cable: Ø max 20 mm Busbar: 1 busbar of 20 x 5 mm |
| Casing Protection Rating | IP40 (IEC529) |
| Drop Test | 1m (IEC68-2-32) |
| Shock Resistance | 100 g (IEC68-2-27) |
| Vibration Resistance | 10 / 55/10 Hz, 0.15 mm (IEC68-2-6) |
| Self-Extinguishing Capability | Casing: UL94 V2Jaws: UL94 V0 |
| Output | 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4mm) |
| Dimensions | 5.3 x 2.0 x 1.18" (135 x 51 x 30 mm) |
| Weight | 0.39 lbs (180 g) |
| Safety Specifications | |
| Electrical Safety | Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC1010-1 & IEC1010-2-032 600V categoryIII, pollution degree 2 300V category IV, pollution degree 2 |
| Electromagnetic Compatibility | EN50081-1: class B EN50082-2 Electrostatic discharge: IEC1000-4-2 Radiated field: IEC1000-4-3 Fast transients: IEC1000-4-4 Magnetic field at 50/60Hz: IEC1000-4-8 |