AEMC Instruments PEL 115 OffersFeatures
Applications
User-Friendly & Built for the Field
The PEL 115 features a durable construction site housing and a mounting kit for easy installation, even on utility poles. Its large, backlit display ensures readability in any environment. Equipped with four voltage inputs and four current inputs, it’s ready for comprehensive power analysis.
Comprehensive RMS & DC Measurements
DataView® Software
The DataView® software simplifies setup, monitoring, and analysis:
Advanced Connectivity
The PEL 115 offers multiple communication options for real-time data access:
General Specifications | |
Number of Voltage Inputs | 4 (V1, V2, V3, Earth/Ground) |
Number of Current Inputs | 4 (L1, L2, L3, Earth/Ground) |
Distribution Systems | Single-/Split-/3-phase, DC, etc. (17 choices) |
Measurements | |
Voltage Range - Phase-Neutral (V) | (10 to 1000) V AC/DC 2 |
Voltage Range - Phase-Phase (U) | (17 to 1700) VAC 2 |
Typical Accuracy - Voltage | ± 0.2 % R ± 0.2 V |
Current Range AC | 200 mA to 12 kAAC |
Current Range DC | 50 mA to 1300 ADC 3 |
Typical Accuracy - Current (Meter Only) 4 | ± 0.4 % R ± 0.04 % Inom |
Network Frequencies | DC/50/60/400 Hz (VFD/PWM not available) |
Calculated Measurements | |
Voltage Ratios | up to 650 kV |
Current Ratios | Not available with AmpFlex®/MiniFlex® sensors |
Power (P, P+ , Punb, Qf, N, D, S) | up to 10 GW/Gvar/GVA 5 |
Energy | up to 4 EWh/EVAh/Evarh 5 |
Phase | cos φ, tan Φ, PF |
Phase Order / Phasor Diagram | Yes / Yes (with DataView® or App for Android™) |
Harmonics | THD for V, A and harmonics to 50th order for V, A |
Recording | |
Aggregations (Fixed) | 200 ms/1 s trends |
Aggregations (Selectable) | (1 to 60) min (12 choices) |
Min/Max Values | Yes |
Alarms | Up to 32 separate alarms |
Emailed Reports | Yes, Alarms and Periodical Min/Max data through DataViewSync® |
Storage Media | SD Card (32 GB Max) |
Recording Length | Several weeks to years (Configuration dependent) |
Other Features | |
Communication | USB, Ethernet/Wi-Fi LAN, Ethernet/Wi-Fi Direct, DataViewSync® |
Software | DataView® included, free App for Android™ |
NEC Article 220.87 - Load Study Compliant | Yes, DataView® configuration button and report templates |
Mounting | Pole mounting kit available (Cat. #2137.82) |
Powered from phase voltage | Yes, from phase-phase or phase-neutral voltage inputs |
External Power Supply | Power Adapter |
Safety and Mechanical | |
Electrical Safety | 1000 V CAT IV per IEC 61010 |
Ingress Protection | IP 67 with included accessories |
Weight | 7.5 lbs (3.4 kg) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.