AEMC PEL 52 Power and Energy Logger, 10 to 600 V, CAT III 600 V
SKU: PEL 52 - w/o sensors
Availability: 2 to 3 Weeks AEMC Instruments PEL 52 – w/o sensors Offers Compact enough to fit into various distribution panels, this power and energy analyzer features water and shock-resistant housing, operates on phase 1 input, and includes a backup battery that charges from the V1 input during measurements. Features Low-cost, simple-to-use, portable, and single/dual/split-phase Wide backlit LCD display Install without cutting off the electr
Availability: 2 to 3 Weeks
AEMC Instruments PEL 52 - w/o sensors Offers
Compact enough to fit into various distribution panels, this power and energy analyzer features water and shock-resistant housing, operates on phase 1 input, and includes a backup battery that charges from the V1 input during measurements.
Features
- Low-cost, simple-to-use, portable, and single/dual/split-phase
- Wide backlit LCD display
- Install without cutting off the electrical network being monitored
- Vital energy data is easily measured, recorded, and analyzed
- True RMS voltage and current measurements up to 600 V
- Powered via the measuring phase
- Measurement of the AC phase currents (I1, I2); sensor dependent (sold separately)
- RMS AC measurements (50 to 60 Hz), aggregation every second without missing measurements
- Easy to use and automatic recognition of current sensors
- W, VA, and var (P, Q, S, N, and D) power measurements
- Calculation of the Cos φ and Power Factor (DPF)
- Aggregation measurements over a period from 1 minute to 1 hour
- Storage of the 1 s and aggregated measurements on SD/SDHC card; data can be read directly on a PC
- Remote connectivity via IRD server
- Integrated web server for remote viewing (AndroidTM, iOS, Windows, etc.)
- Wi-Fi offers accessibility to diagnose problems in real-time and/or multi-station operation
- Data saved on SD card for easier transport
- Includes free DataView® software for configuring, data retrieval, real-time measurement display, data analysis, and report generation
- Compact casing with built-in magnets to facilitate mounting for easier implementation in electrical cabinets
- Eco-design: Environmental aspects considered during product development to make the lowest possible environmental impact throughout the product life cycle
Applications
- Load surveys: Find out how much energy each item of equipment consumes operating at its minimum/maximum power level
- Energy analysis: Estimate energy consumption before and after the improvements
- Energy surveys: The measurements for energy surveys must be performed at several locations on the evaluation site. Starting with the main power, compare the power and energy measurements on the electricity meter and bills. Sub-metering can then be performed on downstream of the installation
AEMC Instruments PEL 52 - w/o sensors Specifications
Specifications
| Key Specifications | |
| Inputs | 2V/2I |
| Types of Installations | Single-phase, split-phase, or two single-phase channels |
| Recording/Data Storage Rate | Unlimited duration (4 GB maximum recording size)/1 second to 1 hour (minimum/average/maximum) |
| Network Frequency | 45 to 65 Hz |
| Voltage | 10 to 600 V |
| Electrical | |
| Voltage | Range:Vrms: 10 to 660 V P to NUrms: 20 to 1200 V P to PResolution:Vrms/Urms: 0.1 VAccuracy:Vrms: ±0.2% reading ±0.2 VUrms: ±0.2% reading ±0.4 V |
| Current Measurement at 50 and 60 Hz | Amps (1 V nominal); excluding clamp accuracyRange: Probe dependent (0.2% < I < 120% Inom)Resolution: Probe dependentAccuracy: ±0.2% reading±0.02 Inom |
| Power | Watts P-Q-S (W-var-VA)Range: V = 100 to 660 V; I = 5 to 120% InomResolution: Probe dependentAccuracy: ±0.3% R ±0.003% Pnom±1% R ±0.01% Qnom±0.3% R ±0.003% SnomPower factorRange: -1 to 1Resolution: 0.001Accuracy: ±0.02%Cos φ (DPF):Range: -1 to 1Resolution: 0.001Accuracy: ±0.05% |
| Energy | Ep-Eq-Es (Wh, varh, VAh)Range: V = 100 to 660 V; I = 5 to 120% InomResolution: 0.001 and ±0.02%Accuracy:±0.5% reading±2.5% reading±0.5% reading |
| General Specifications | |
| Communication | Wi-Fi (access point and hot spot) |
| Data Storage | 8 GB SD card (included); expandable to 32 GB |
| Display Type | LCD with blue backlight |
| Real-Time Clock | Time and date stamp for Trend mode |
| Environmental | Operating temperature/relative humidity: -4 to 122°F (-20 to 50°C)/10 to 85% RHStorage temperature/relative humidity: -40 to 158°F (-40 to 70°C)/0 to 95% RH without battery |
| Safety | Electro-Magnetic Compatibility (EMC): EN 61326-1 for emission and immunitySafety rating/CE rating: IEC/EN 61010-2-30 (600 V CAT III)/YesIP rating: IP54 per IEC 60529 |
| Case | Compact and rugged, shock and vibration IEC 61010 |
| Power Supply | From phase 1, 90 to 660 V battery backup when power OFFBattery life: 3 hours without Wi-Fi, 1 hour typical with Wi-Fi enabled |
| Dimensions | 7.08 x 3.46 x 1.45" (180 x 88 x 37 mm) |
| Weight | 14.1 oz (400 g) |
What's included with the AEMC Instruments PEL 52 - w/o sensors
- Power and Energy Logger
- 3 x Black Test Leads and Alligator Clips
- 8 GB SD Card
- USB SD Card Reader
- Soft Carrying Case
- 2 x AAA Rechargeable Batteries
- Power Cord with Adapter
- USB Drive with DataView® Software and User Manual
- Quick Start Guide
- Two-Year Warranty
AEMC PEL 52 Power and Energy Logger, 10 to 600 V, CAT III 600 V. Great savings PLUS Free Shipping when you order today on EquipTestPro.com.