Dent ElitePro EXCN-I-N-L Energy Data Logger, Int'l, USB/Ethernet

$3,112.94

Availability: 2 to 3 Weeks

Dent EXC-U-B-C Offers

A dependable and versatile tool for measuring energy usage

The Energy Data Logger Kit is a complete solution for pinpointing electric usage and quantifying energy usage. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The Energy Data Logger uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers or flexible RoCoils™ (for large loads or large cables and bussbars) to monitor current on each phase.

These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Electrical load diagnostic parameters, such as displacement power factor, are captured in addition to energy and demand values.

The Energy Data Logger's flexibility, size, and ease-of-use make it the ideal tool for gathering detailed consumption information in commercial, industrial, government and retail environments.

Four Analog Input Channels: Correlate your consumption with environmental conditions

New to the Energy Data Logger are 4 analog input channels which can be configured for voltage or current input used in any combination among channels. Analog inputs are especially helpful when used in conjunction with power measurements to correlate the consumption of electricity with environmental, HVAC/R plant performance, or other process conditions. Typical uses might include logging ambient temperature, building temperatures, solar insolation, tank pressures, duct flows, etc. Obtain this valuable data using just one meter: the ELITEpro XC.

Key Features

  • For single or 3-phase systems using 80 to 600 V phase-to-phase (AC or DC) services when line powered or 0 to 600 V (AC or DC) when externally powered. Measures up to four channels of energy metrics with currents ranging from 0 to 6000 amps.
  • Analog Inputs record analog data with configurable input ranges for voltage (0 to 15 VDC) or current loop (0 or 4 to 20 mA) transducers. Analog inputs are used for process or environmental correlation studies with power.
  • Line-powered - no need for batteries or external power source.
  • User-selectable recording intervals as short as every 1 second
  • 16 MB non-volatile memory standard for months of recording time.
  • Better than 1% accuracy (<0.2% typical).
  • Fast USB connection and standard Ethernet port.
  • ELITEpro XC may be configured with optional Bluetooth® wireless technology.
  • Optional Wi-Fi interface allows for remote data collection over wireless networks. Check real-time values using a Wi-Fi-enabled laptop, tablet, or smartphone via a web browser.
  • Simple yet powerful Windows-based ELOG™ software package for setup, data retrieval, and analysis. Easy data exporting to almost any analysis program.
  • Easy to setup and installs in minutes. Patented PhaseChek™ LED indicators ensure correct CT orientation at installation.
  • Rugged and compact-easily fits inside breaker panels and switch gear.
Hardware Features

PhaseChek™

PhaseChek lights verify that that the CTs are correctly installed - green is good, red means that either a CT is incorrectly installed or that a CT is in the wrong orientation.

Mount Inside or Beside

Mount the ELITEpro XC inside the panel using the mounting magnets or beside the panel using the mounting tab

Log with Confidence

Indicator lights show that the meter is recording

Standard Ethernet Port

The Ethernet and USB ports are standard equipment, no additional costs

Connections

Voltage

Connections via fused or unfused crocodile clips or shark clips

Current

Use up to four channels of current via CTs connected to a terminal block

Power

Power is supplied via the voltage connections - no auxiliary supply is required

Communications Options

Ethernet & USB

The Ethernet and USB ports are standard equipment

WiFi

Use optional WiFi to setup, record and view data remotely

WiFi with Antenna

Optional WiFi with external antenna provides 3dbi gain

Bluetooth

Optional Bluetooth provides short-range wireless configuration

Connect with USB (standard Equipment)

Connect directly to the ELITEpro XC via the included A-to-B USB cable.

Connect with Ethernet (standard equipment)

Connect remotely to the logger via 10/100 MB Ethernet using DHCP or static IP to manually or automatically download data or reconfigure

Connect with Wi-Fi (optional)

The optional Wi-Fi interface allows the meter to be connected to a Wi-Fi network and accessed from any PC on the network using ELOG software. Alternatively, configure the Energy Data Logger as its own Wi-Fi hotspot and view real-time data using a Wi-Fi enabled PC, tablet, or smart phone via a web browser from up to 300' away. Two antenna options are available: internal antenna (75 to 300') or external 3 dbi antenna (150 to 300'). Use ELOG to switch between WiFi and QuickView™ access point mode

Connect with BlueTooth® (optional)

Save time and meet safety requirements by communicating with an ELITEpro XC without removing the electrical panel door. In addition to the standard USB and Ethernet ports, ELITEpro XC instruments may be equipped with an optional Bluetooth® wireless technology interface, which will allow a PC with a Bluetooth® wireless technology adapter running ELOG to connect to the ELITEpro XC over short distances (10 to 100' typical) to send setup tables or download data. PC must support Serial Port Profile (SPP)

Current Transformers

An Industry-Leading Selection of Quality Transformers

Choose from an interchangeable selection of CT options including split-core, clamp-on, hinged and flexible RoCoil™ types. The ELITEpro XC comes with an embedded Rogowski coil CT amplifier/integrator circuit so there is no need to provide external power when using our line of flexible RoCoil™ CTs.

All DENT CTs are internally shunted for intrinsically safe operation on energized conductors. Special high-accuracy CTs are available for existing CT secondary monitoring. The ELITEpro XC can monitor up to four single-phase loads, two three-phase (3-wire) Delta loads or one three-phase (4-wire) WYE load.

Software

ELOG software is used to program the meter, display metered values, and retrieve and analyze the collected data.

ELOG graphically displays recorded data, performs analysis, and facilitates automatic remote data collection. Data is also easily exported to popular spreadsheet and database programs for additional analysis.

You are provided with an unlimited site license to the software with purchase.

Outdoor Applications

Our optional NEMA 4 rated weathertight drop-in enclosure delivers stronger environmental integrity, separate voltage plugs, watertight connectors for both the current leads and the power and communication cables. This option for the ELITEpro XC will meet the stringent requirements of remote data logging.

Additional Features

Line Powered with Reduced Impact on Environment:

The ELITEpro XC is powered directly from the phases of the service being measured. It incorporates a broadband power supply which operates on virtually any 80-600V phase-to-phase service. You will not have to worry about constantly changing or recharging batteries, nor finding an external power source at the job site. And you will avoid the negative environmental impact of disposing of batteries containing rare earth materials that are difficult to recycle or reclaim.

Memory for Extended Recording

Measurements are stored in on-board memory at recording intervals selected by the user, which can be as short as one second or as long as once every 24 hours. The ELITEpro XC has 16MB of internal non-volatile memory, which allows for long-term logging sessions. For example, the ELITEpro XC can record a WYE setup with all available system measurements using a 2 minute integration interval for over 160 days!

Bi-Directional Metering for Renewable Studies

The ELITEpro XC design delivers bi-directional metering, which is capable of monitoring power generated by a renewable energy source versus power imported from the grid-ideal for solar power measurements.

Fast Sampling Rate Captures Power Quality Data

Regardless of the user-selectable recording interval, the ELITEpro XC has a waveform sampling frequency of 12 kHz. This is the number of data points the logger samples on each AC waveform (200 points per cycle at 60 Hz; 240 points per cycle at 50 Hz). This fast sampling rate allows for real-time display of voltage, current waveforms, and harmonics. The channel sampling rate is 8 Hz or every 125 mSec.

Field-Proven: Rugged & Compact

Measuring in at only 21.6 x 6.3 x 4.7 cm (8.5 x 2.5 x 1.9") and weighing 340 g (12 oz), the ELITEpro XC was designed to fit inside panels for safety and convenience. Its rugged plastic housing is even supplied with magnets on the housing to facilitate mounting. Our optional NEMA 4 rated weathertight drop-in enclosure delivers stronger environmental integrity, separate voltage plugs, water-tight connectors for both the current leads and the power and communication cables. This option for the ELITEpro XC will meet the stringent requirements of remote data logging.

What Happens to the ELITEpro XC During a Power Outage?

One question that we're frequently asked is this: "What happens to my ELITEpro XC during a power outage?"

The ELITEpro XC has 16 MB of non-volatile memory. It's a line-powered device, which means that it's powered by the L1 to L2 voltage under measurement.

During a power outage, the meter ceases to be energized because it's powered by the voltage in the panel under measurement. Although the logger stops recording, the built-in memory means the logger maintains all its records and settings. Once power is restored, the meter will continue to record.

There is a feature in ELOG software to help with this scenario called "Fill Missing Records." This feature detects gaps in the time sequence of the data and fills the missing records with 0 values. This feature is useful any time there are gaps in the time stamp records.

Applications

  • Measurement and Verification (M&V) Studies
  • Electrical Load Profiling
  • Energy Audits
  • New Technology Assessment Studies

Download the App



Dent EXCN-I-N-L Specifications
  • Internal antenna: typical range 75 to 300'
  • External 3 dbi antenna: typical range 150 to 300'

* Performance varies at 400 Hz operation. Contact the factory for details. † ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG. US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.



Specifications

Service TypeSingle phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery)
Voltage Channels3 channels, CAT III, 0 to 600 VAC (line-to-line) or 600 VDC
Current Channels4 channels, 0.67 VAC max, +/- 1 VDC Ideal for 333 mV full scale CTs
Maximum Current InputExternal transducer dependent 200% of current transducer rating (mV CTs) Measure up to 6000 A with RoCoil CTs.
Measurement TypeTrue RMS using high-speed digital signal processing (DSP)
Line FrequencyDC/50/60/400 Hz*
Waveform Sampling12 kHz
Channel Sampling Rate0.125 seconds
Integration Period1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
Energy MeasurementsVolts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total
Analog Measurements0 to 10 V, 0 or 4 to 20 mA current loop Non-isolated, external power for current loop. User scaling for sensor reporting in physical units
AccuracyBetter than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
Resolution0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
LED IndicatorsTri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™).
Line-PowerFrom L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max Non-user replaceable 0.5 A internal fuse protection.
Power In6 to 10 VDC, 500 mA
Power Out6 VDC, 200 mA max
USB (Standard)USB standard (type B) 6' (1.8 m) A-to-B USB cable (included)
Ethernet (Standard)Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better Configure for DHCP or static IP
Bluetooth Wireless Technology (Optional)Internal antenna with 10 to 100' range (typical) Requires Bluetooth® wireless technology adapter on Windows PC Adapter must support the Serial Port Profile (SPP).
Wi-Fi Adapter† (optional)Wi-Fi option available as two separate configurations: Internal antenna: typical range 75 to 300' External 3 dbi antenna: typical range 150 to 300'
Operating Temperature20 to 140 °F (-7 to 60 °C)
Operating Humidity5 to 95% non-condensing
Enclosure TypeABS plastic, 94-V0 flammability rating
Weight12 ounces (340 g)
Dimensions8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm)


Connect to a remote ELITEpro XC using Port Forwarding

What happens if your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download and, with a little planning, you probably already have everything you need to successfully download your data.

Port forwarding is a name given to the combined technique of:

  • Translating the address and/or port number of a packet to a new destination
  • Possibly accepting such packets in a packet filter (firewall)
  • Forwarding the packet according to the routing table

Port forwarding allows remote computers (for example, computers on the Internet) to connect to a specific computer or service within a private local area network (LAN). In the case of the ELITEpro XC (or ELITEpro SP) with Ethernet, port forwarding allows remote connection between the ELITEpro XC and a computer on another network through the firewall via ELOG software.

For instance, if the ELITEpro XC is on the local area network at a remote project site, but you wish to download data off the meter from the office, you can remotely access the ELITEpro XC from any computer with an Internet connection through ELOG.

Requirements

Prior to beginning, confirm the following information:

  • Know the external IP address of the router on the network with the ELITEpro XC. This address is usually assigned by the ISP and is typically static. However, it may be dynamic, changing the address every other day. This can be easily found by someone inside the network by visiting www.whatsmyip.com
  • Confirm that your router can be configured for port forwarding. Verify this with your router's documentation or by visiting the manufacturer's website
  • Know the ELITEpro XC meter's IP address

Note: The ELITEpro XC itself does not need to be configured for Port Forwarding. All the configuration takes place on the router.

Each router manufacturer uses slightly different software. Check your router's documentation for specific directions on how to port forward with your router's software. Regardless of what software is on your router, you'll be required to enter the same general information.

  • A text field where you can type the name of the application or service (in this case, it's helpful to reference the "ELITEpro XC" or the EXC's serial number)
  • Incoming port the router should watch for
  • The protocol to watch for: TCP or UDP. Choose "both" if you're unsure
  • The IP address that is the destination for this port's request (i.e., the EXC's IP address)
  • Which port the request should be targeted to on the destination IP. The default is 3001

Instructions

Here are the steps to connecting your networked ELITEpro XC from a different network:

  • Obtain an internal IP address that is routable to an external IP address. If you are unsure of which IP address to use, check with your IT department
  • The external IP address gets forwarded to the internal IP address. For instance, the external IP address 212.45.67.89 may be forwarded to internal IP address 192.168.1.50.
  • Determine which port should e used to connect to the ELITEpro XC. The default port is 3001. Check with your IT department if you are unsure
  • Using ELOG on the remote PC, go through the menu: Logger > Communication > Network Connect
  • Enter the external IP address for the network you wish to connect to in the Network IP address box
  • Enter the Port Number for the logger you wish to connect to
  • Click OK
  • You should now be connected to the remote ELITEpro XC
Shipping & Return Policy — EquipTestPro
Last Updated: February 1, 2026
Legal Policies

Shipping & Return Policy

Everything you need to know about orders, cancellations, refunds, and delivery.

🌎
Section 01
Shipping Destinations

EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.

Please Note: Certain products are subject to restrictions and cannot be shipped to all destinations. Product-specific shipping availability is noted on each item's detail page. We do not currently ship to international destinations outside of Canada and the United States.
💲
Section 02
Shipping Rates

When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.

Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.

⚖️
Section 03
Weight-Based Shipping

For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.

Rounding Policy: To align with the policies of our shipping carriers, all item weights are rounded up to the next full pound when calculating shipping costs.

For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.

⚠️
Section 04
Product Restrictions

Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:

  • Hazardous or regulated materials
  • Oversized or freight-class items
  • Products restricted by provincial or state import regulations
  • Items that cannot be air-shipped due to their composition

Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.

🕐
Section 05
Order Processing

Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.

1
Order Confirmed You receive an email confirmation with your order details.
2
Order Processed Your order is verified and prepared for shipment (1–2 business days).
3
Shipped You receive a tracking number by email once your package is dispatched.
4
Delivered Delivery timelines vary by destination and carrier availability.
Section 01
Order Cancellation Rights

You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.

The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.

To exercise your cancellation right, notify us with a clear written statement by:

  • Email: info@equiptestpro.com
  • Online form: equiptestpro.com/contact-us
💳
Section 02
Cancellation Processing Fees

The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.

Customer-Initiated
10%

A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.

Company-Initiated (Item Unavailable)
$0

If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.

Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.

Section 03
Conditions for Returns

To be eligible for a return, all of the following conditions must be met:

  • The Goods were purchased within the last 30 days
  • The Goods are in their original, undamaged packaging
  • The Goods are unused and unaltered from the condition received
  • A valid receipt or proof of purchase accompanies the return
Sale Items: Only regular-priced Goods are eligible for a refund. Items purchased on sale or at a discounted price cannot be refunded. This exclusion may not apply where prohibited by applicable law.

We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.

🚫
Section 04
Non-Returnable Goods

The following items are not eligible for return under any circumstances:

  • Goods made to your specifications or clearly personalized
  • Goods that by their nature are not suitable for return, deteriorate rapidly, or where the expiry date has passed
  • Goods not suitable for return due to health protection or hygiene reasons that have been unsealed after delivery
  • Goods that, after delivery, have become inseparably mixed with other items by their nature
  • Goods purchased on sale or at a promotional discount
📬
Section 05
How to Return Goods

You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.

Important: We strongly recommend using an insured and trackable mail service. We cannot be held responsible for Goods damaged or lost during return shipment, and we are unable to issue a refund without confirmed receipt of the returned Goods or verifiable proof of delivery.
Section 06
Refund Timeline

You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:

1
Transit to Us 5 to 10 business days for us to receive your return from the shipper.
2
Return Processing 3 to 5 business days to inspect and process your return once received.
3
Bank Processing 5 to 10 business days for your bank to post the refund to your account.

We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.

🎁
Section 07
Gift Returns

If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.

If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.

Questions? We're here to help.

Reach out to our support team for assistance with any order or return.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns