1-587-566-0049
Dwyer RHP-2N40-LCD Humidity, Temperature and Dew Point Transmitter, 0 to 100% RH, -40 to 140°F
2 in stock

Dwyer RHP-2N40-LCD Humidity, Temperature and Dew Point Transmitter, 0 to 100% RH, -40 to 140°F

SKU: RHP-2N40-LCD

$250.87

Availability: 2 to 3 Weeks Dwyer RHP-2N40-LCD Offers Features Reduced installation cost with combined humidity and temperature Reduced system operating costs with radiation shield protecting the sensor from radiant heat Applications Air economizers Outdoor temperature and relative humidity reference for building systems Pool room humidity monitoring Dwyer RHP-2N40-LCD Specifications Specifications Relative Humidity Range 0 to 100% RH Temperatu

1
Request a Quote
Secure Checkout
Fast Shipping
Authorized Dealer

Availability: 2 to 3 Weeks

Dwyer RHP-2N40-LCD Offers

Features

  • Reduced installation cost with combined humidity and temperature
  • Reduced system operating costs with radiation shield protecting the sensor from radiant heat

Applications

  • Air economizers
  • Outdoor temperature and relative humidity reference for building systems
  • Pool room humidity monitoring

Dwyer RHP-2N40-LCD Specifications

Specifications

Relative Humidity Range 0 to 100% RH
Temperature Range -40 to 140°F (-40 to 60°C) for thermistor and RTD sensors-20 to 140°F (-28.9 to 60°C) for solid state band gap temperature sensors
Dew Point Temperature Range -20 to 140°F (-28.9 to 60°C)0 to 100°F (-17.8 to 37.8°C)40 to 90°F (4.4 to 32.3°C)-4 to 140°F (-20 to 60°C)'Field-selectable ranges
Accuracy ±2% (10 to 90% RH @ 25°C)Thermistor temperature sensor: ±0.36°F @ 77°F (±0.2°C @ 25°C)RTD temperature sensor: DIN Class B; ±0.54°F @ 32°F (±0.3°C @ 0°C)Solid state band gap temperature sensor: ±0.9°F @ 77°F (±0.3°C @ 25°C)
Hysteresis ±0.8%
Repeatability ±0.1% typical
Temperature Limits Operating: -40 to 140°F (-40 to 60°C)Storage: -40 to 176°F (-40 to 80°C)
Compensated Temperature Range -4 to 140°F (-20 to 60°C)
Power Requirements 4-20 mA loop powered outputs: 10 to 35 V DC0-5/10V outputs: 15 to 35 V DC or 15 to 29 V AC
Output Signals 4-20 mA loop powered outputs: 4-20 mA, 2 channels for humidity/solid state temperature sensor models (loop powered on RH). Switch selectable RH/dew point. Switch selectable normal or reverse output.0-5/10V outputs: 5 mA max., 2 channels for humidity/solid state temperature sensor models. Switch selectable 0-10 V/2-10 V or 0-5 V/1-5 V output. Switch selectable RH/dew point. Switch selectable normal or reverse output.
Solid State Band Gap Temperature Sensor Output Ranges Switch selectable:-20 to 140°F (-28.9 to 60°C)0 to 100°F (-17.8 to 37.8°C)40 to 90°F (4.4 to 32.3°C)-4 to 140°F (-20 to 60°C)
Response Time 8 s
Electrical Connections Screw terminal block
Drift <0.25% RH/year
RH Sensor Capacitance polymer
Enclosure Material Polycarbonate
Enclosure Rating IP20
Agency Approvals CE
Display Optional LCD; switch selectable %RH or dew point, °F/°CDisplay resolution: RH: 1%Temperature: 0.1°F (0.1°C)Dew point: 1°F (1°C)
Weight 4.4 oz (125 g)

What's included with the Dwyer RHP-2N40-LCD

  • Dwyer RHP-2N40-LCD Humidity, Temperature and Dew Point Transmitter, 0 to 100% RH, -40 to 140°F

Dwyer RHP-2N40-LCD Humidity, Temperature and Dew Point Transmitter, 0 to 100% RH, -40 to 140°F. Great savings PLUS Free Shipping when you buy now from EquipTestPro.com.