Compact and rugged, this oscilloscope is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. Features innovative functions that help technicians troubleshoot faster for quicker results and to keep their systems running smoothly. Additionally, triggering displays waveforms without having to adjust amplitude, timebase, and trigger settings.

Features

  • Key measurements: Power waveforms with numerical values including resistance, diode, continuity and capacitance measurements
  • Automatically capture, view and analyze complex waveforms: Fluke Connect and View™ triggering automatically displays waveforms without having to adjust amplitude, timebase and trigger settings, while Intellaset™ technology analyzes the signal and automatically displays critical numerical readings, making troubleshooting faster than ever
  • View data locally on the instrument, or via Fluke Connect mobile app
  • Dual-input digital oscilloscope and multimeter
  • 20 MHz oscilloscope bandwidth
  • Two 5000-count True RMS digital multimeters
  • Connect-and-View trigger simplicity for hands-off operation
  • IntellaSet technology automatically and intelligently adjusts numerical readout based on the measured signal
  • Dual-input waveform and meter reading recorder for trending data over extended periods
  • Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
  • Shielded test leads for oscilloscope, resistance and continuity measurements
  • Resistance, continuity, diode and capacitance meter measurements
  • Power measurements (W, VA, VAR, PF, DPF, Hz)
  • Save or recall data and instrument setups
  • Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
  • External optically isolated USB interface to transfer, archive and analyze scope or meter data
  • Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect mobile app
  • Rugged design to withstand 3 g Vibration, 30 g shock, and rated IP51 according to EN/IEC60529
  • Highest safety rating in the industry: safety rated for CAT IV 600 V

Connect-and-View triggering for an instant, stable display

Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument's unique Connect-andView triggering technology recognizes signal patterns and automatically sets up the correct triggering to provide a stable, reliable, and repeatable display. Connect-and-View triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.

IntellaSet/AutoReading

The Auto Readings function with Fluke IntellaSet technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on the screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the Vpeak-peak, and Hz readings are automatically displayed. Using IntellaSet technology in conjunction with Connect-and-View automatic triggering you can be sure you're seeing not only the correct waveform but the appropriate numerical reading as well. All without touching a button.

Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements

For single-phase or 3-phase balanced systems, the dual inputs of this industrial ScopeMeter can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B.

One test lead to measure multiple electrical parameters

High-frequency waveform, meter, capacitance, and resistance measurements as well as continuity checks are all covered by a single set of shielded test leads. No time is wasted finding or swapping leads.

Fluke Connect mobile app compatibility

Automated industrial machinery is harder than ever to troubleshoot. It's not enough to just know where you have to test, you also have to know what to look for and that can be hard without baseline measurement data or access to subject matter experts. This Fluke Connect Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.

Use the comprehensive recorder modes to help find intermittent faults with ease

The toughest faults to find are those that happen only once in a while-intermittent event. They can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see them. But, your ScopeMeter test tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data set.

Applications

Ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications.



Fluke 123B/S Specifications

Specifications

Oscilloscope Mode (Vertical)
Frequency Response - DC CoupledWithout probes and test leads (with BB120): DC to 20 MHz (-3 dB) With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB) With VP41 10:1 probe: DC to 20 MHz (-3 dB)
Frequency Response - AC Coupled (LF Roll Off)Without probes and test leads: <10 Hz (-3 dB) With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB) With VP41 10:1 probe: <10 Hz (-3 dB)
Rise Time, Excluding Probes, Test Leads<17.5 ns
Input ImpedanceWithout probes and test leads: 1 MΩ/20 pF With BB120: 1 MΩ/24 pF With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF With VP41 10:1 probe: 5 MΩ/15.5 pF
Sensitivity5 mV to 200 V/div
Analog Bandwidth Limiter10 kHz
Display ModesA, -A, B, -B
Maximum Input Voltage A and BDirect, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage With BB120: 600 Vrms
Maximum Floating Voltage, from any Terminal to Ground600 Vrms CAT IV, 750 Vrms up to 400 Hz
Oscilloscope Mode (Horizontal)
Scope ModesNormal, single, roll
Ranges (Normal)Equivalent sampling: 20 ns to 500 ns/div Real time sampling: 1 μs to 5 s/div Single (real time): 1 μs to 5 s/div Roll (real time): 1 s to 60 s/div
Sampling Rate (for Both Channels Simultaneously)Equivalent sampling (repetitive signals): up to 4 GS/s Real time sampling 1 μs to 60 s/div: 40 MS/s
Trigger
Screen UpdateFree run, on trigger
SourceA, B
Sensitivity A and BAt DC to 5 MHz: 0.5 divisions or 5 mV At 40 MHz: 4 divisions
SlopePositive, negative
Advanced Scope Functions
Display ModesNormal: Captures up to 25 ns glitches and displays analog-like persistence waveform Smooth: Suppresses noise from a waveform Glitch off: Does not capture glitches between samples Envelope: Records and displays the minimum and maximum of waveforms over time
Auto Set (Connect-and-View)Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level
Input A and B
DC Voltage (V DC)Ranges: 500 mV, 5, 50, 500, 750 V Accuracy: ±(0.5% +5 counts) Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz Full scale reading: 5000 counts
True RMS Voltages (V AC and V AC+DC)Ranges: 500 mV, 5, 50, 500, 750 V Accuracy for 5 to 100% of range (DC coupled) DC to 60 Hz (V AC + DC): ±(1% +10 counts) 1 to 60 Hz (V AC): ±(1% +10 counts) Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts) DC rejection (only V AC): >50 dB Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz Full scale reading: 5000 counts, reading is independent of any signal crest factor
PeakModes: Maximum peak, minimum peak, peak-to-peak Ranges: 500 mV, 5, 50, 500, 2200 V Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale Full scale reading: 500 counts
FrequencyRanges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 50 MHz Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts) Full scale reading: 10,000 counts
RPMMaximum reading: 50 kRPM Accuracy: ±(0.5% +2 counts)
Duty CycleRange: 2 to 98% Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse WidthFrequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset Full scale reading: 1000 counts
AmperesWith current clamp Ranges: same as V DC, V AC, V AC+DC, or peak Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty)
Decibel0 dBV: 1 V 0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω dB on V DC, V AC, or V AC+DC Full scale reading; 1000 counts
Crest FactorRange: 1 to 10 Full scale reading: 90 counts
PhaseModes: A to B, B to A Range: 0 to 359° Resolution: 1°
VpwmPurpose: To measure on pulse width modulated signals, like motor drive inverter outputs Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency Accuracy: As Vrms for sine wave signals
Input A to Common
OhmRanges: 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts) Full scale reading: 50 Ω to 5 MΩ - 5000 counts; 30 MΩ - 3000 counts Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges Open circuit voltage: <4 V
Common Continuity (Cont)Beep: <(30 Ω ±5 Ω) in 50 Ω range Measurement current: 0.5 mA Detection of shorts of: ≥1 ms
Common DiodeMeasurement voltage: At 0.5 mA: >2.8 V At open circuit: <4 V Measurement current: 0.5 mA Polarity: + on input A, - on COM
Capacitance (CAP)Ranges: 50, 500 nF, 5, 50, 500 μF Full scale reading: 5000 counts Measurement current: 500 nA to 0.5 mA, increases with increasing ranges
Advanced Meter Functions
Zero SetSet actual value to reference
AutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals
Fixed Decimal PointActivated by using attenuation keys
Recorder
Meter ReadingsMeasurement speed: Maximum 2 measurements Record size (minimum, maximum, average): 2 M readings for 1 channel Recorded time span: 2 weeks Maximum number of events: 1024
Waveform RecordMaximum sample rate: 400 K samples Size internal memory: 400 M samples recorded time Span internal memory: 15 minutes at 500 μs/div; 11 hours at 20 ms/div Record size SD card: 1.5 G samples Recorded time span SD card: 11 hours at 500 μs/div; 14 days at 20 ms/div Maximum number of events: 64
General Specifications
Waveform DisplayVertical: 10 div of 40 pixels Horizontal: 12 div of 40 pixels
Maximum Input Voltage A and BDirect on input or with leads: 600 Vrms CAT IV for derating With banana-to BNC adapter BB120: 600 Vrms for derating Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz
DisplayType: 5.7" color active martrix TFT Resolution: 640 x 480
InterfaceOptically isolated: Transfer screen copies (bitmaps), settings and data USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®
Wireless Radio with AdapterFrequency range: 2412 to 2462 MHz Output power: <100 mW
EnvironmentalMIL-PRF-28800F, Class 2
TemperatureBattery operation: 32 to 104°F (0 to 40°C) Power adapter operation: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) non-condensing
Humidity (Operating)At 32 to 50°F (0 to 10°C): non-condensing At 50 to 86°F (10 to 30°C): 95% At 86 to 104°F (30 to 40°C): 75% At 104 to 122°F (40 to 50°C): 45%
AltitudeOperating at 10,000' (3 km): CAT III 600 V Operating at 6600' (2 km): CAT IV 600 V Storage: 40,000' (12 km)
EMC Electromagnetic CompatibilityUSA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)
Enclosure ProtectionIP51, ref: EN/IEC60529
SafetyGeneral: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
MemoryInternal memory can store 20 data sets (screen waveform and setup) Micro SD card slot with optional SD card (maximum size of 32 GB)
PowerExternal: Via power adapter BC430 Input voltage: 10 to 21 V DC Consumption: 5 W typical Input connector: 5 mm jack Internal: Via battery pack BP290 Battery power: Rechargeable Li-Ion 10.8 V Operating time: 7 hours with 50 % backlight brightness Charging time: 4 hours with test tool off, 7 hours with test tool on Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging
Dimensions10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
Weight3.2 lbs (1.4 kg) including battery pack


What's included with the Fluke 123B/S
  • Oscilloscope
  • 2 x Shielded Test Leads with Ground Leads
  • Black Test Lead
  • Red and Blue Hook Clips
  • Banana to BNC Adapter
  • Wi-Fi USB Adapter
  • Magnetic Hanger
  • Screen Protector
  • Soft Carrying Case
  • Li-Ion Battery Pack
  • Charger/Power Adapter
  • FlukeView™ for Windows® Software
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns