Fluke 124B OffersCompact and rugged, this oscilloscope is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. Features innovative functions that help technicians troubleshoot faster for quicker results and to keep their systems running smoothly. Additionally, triggering displays waveforms without having to adjust amplitude, timebase, and trigger settings.
Features
Connect-and-View triggering for an instant, stable display
Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument's unique Connect-andView triggering technology recognizes signal patterns and automatically sets up the correct triggering to provide a stable, reliable, and repeatable display. Connect-and-View triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.
IntellaSet/AutoReading
The Auto Readings function with Fluke IntellaSet technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on the screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the Vpeak-peak, and Hz readings are automatically displayed. Using IntellaSet technology in conjunction with Connect-and-View automatic triggering you can be sure you're seeing not only the correct waveform but the appropriate numerical reading as well. All without touching a button.
Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements
For single-phase or 3-phase balanced systems, the dual inputs of the Industrial ScopeMeter 120B Series can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B. This oscilloscope can then calculate; frequency, phase angle, active power (kW), reactive power (VA or var), power factor (PF), or displacement power factor (DPF) and can also calculate the power values for a 3-phase system where all phases have equal voltage and currents. This applies to both balanced systems and resistive loads.
One test lead to measure multiple electrical parameters
High-frequency waveform, meter, capacitance, and resistance measurements as well as continuity checks are all covered by a single set of shielded test leads. No time is wasted finding or swapping leads.
Fluke Connect mobile app compatibility
Automated industrial machinery is harder than ever to troubleshoot. It's not enough to just know where you have to test, you also have to know what to look for and that can be hard without baseline measurement data or access to subject matter experts. This Fluke Connect Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.
Use the comprehensive recorder modes to help find intermittent faults with ease
The toughest faults to find are those that happen only once in a while-intermittent event. They can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see them. But, your Fluke ScopeMeter Test Tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data set.
Applications
Ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications
| Oscilloscope Mode (Vertical) | |
| Frequency Response - DC Coupled | Without probes and test leads (with BB120): DC to 40 MHz (-3 dB) With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB) With VP41 10:1 probe: DC to 40 MHz (-3 dB) |
| Frequency Response - AC Coupled (LF Roll Off) | Without probes and test leads: <10 Hz (-3 dB) With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB) With VP41 10:1 probe: <10 Hz (-3 dB) |
| Rise Time, Excluding Probes, Test Leads | <8.75 ns |
| Input Impedance | Without probes and test leads: 1 MΩ/20 pF With BB120: 1 MΩ/24 pF With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF With VP41 10:1 probe: 5 MΩ/15.5 pF |
| Sensitivity | 5 mV to 200 V/div |
| Analog Bandwidth Limiter | 10 kHz |
| Display Modes | A, -A, B, -B |
| Maximum Input Voltage A and B | Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage With BB120: 600 Vrms |
| Maximum Floating Voltage, from any Terminal to Ground | 600 Vrms CAT IV, 750 Vrms up to 400 Hz |
| Oscilloscope Mode (Horizontal) | |
| Scope Modes | Normal, single, roll |
| Ranges (Normal) | Equivalent sampling: 10 ns to 500 ns/div Real time sampling: 1 μs to 5 s/div Single (real time): 1 μs to 5 s/div Roll (real time): 1 s to 60 s/div |
| Sampling Rate (for Both Channels Simultaneously) | Equivalent sampling (repetitive signals): up to 4 GS/s Real time sampling 1 μs to 60 s/div: 40 MS/s |
| Trigger | |
| Screen Update | Free run, on trigger |
| Source | A, B |
| Sensitivity A and B | At DC to 5 MHz: 0.5 divisions or 5 mV At 40 MHz: 1.5 divisions At 60 MHz: 4 divisions |
| Slope | Positive, negative |
| Advanced Scope Functions | |
| Display Modes | Normal: Captures up to 25 ns glitches and displays analog-like persistence waveform Smooth: Suppresses noise from a waveform Glitch off: Does not capture glitches between samples Envelope: Records and displays the minimum and maximum of waveforms over time |
| Auto Set (Connect-and-View) | Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level |
| Input A and B | |
| DC Voltage (V DC) | Ranges: 500 mV, 5, 50, 500, 750 V Accuracy: ±(0.5% +5 counts) Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz Full scale reading: 5000 counts |
| True RMS Voltages (V AC and V AC+DC) | Ranges: 500 mV, 5, 50, 500, 750 V Accuracy for 5 to 100% of range (DC coupled) DC to 60 Hz (V AC + DC): ±(1% +10 counts) 1 to 60 Hz (V AC): ±(1% +10 counts) Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts) DC rejection (only V AC): >50 dB Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz Full scale reading: 5000 counts, reading is independent of any signal crest factor |
| Peak | Modes: Maximum peak, minimum peak, peak-to-peak Ranges: 500 mV, 5, 50, 500, 2200 V Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale Full scale reading: 500 counts |
| Frequency | Ranges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 70 MHz Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts) Full scale reading: 10,000 counts |
| RPM | Maximum reading: 50 kRPM Accuracy: ±(0.5% +2 counts) |
| Duty Cycle | Range: 2 to 98% Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset |
| Pulse Width | Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset Full scale reading: 1000 counts |
| Amperes | With current clamp Ranges: same as V DC, V AC, V AC+DC, or peak Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty) |
| Decibel | 0 dBV: 1 V 0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω dB on V DC, V AC, or V AC+DC Full scale reading; 1000 counts |
| Crest Factor | Range: 1 to 10 Full scale reading: 90 counts |
| Phase | Modes: A to B, B to A Range: 0 to 359° Resolution: 1° |
| Vpwm | Purpose: To measure on pulse width modulated signals, like motor drive inverter outputs Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency Accuracy: As Vrms for sine wave signals |
| Input A to Common | |
| Ohm | Ranges: 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts) Full scale reading: 50 Ω to 5 MΩ - 5000 counts; 30 MΩ - 3000 counts Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges Open circuit voltage: <4 V |
| Common Continuity (Cont) | Beep: <(30 Ω ±5 Ω) in 50 Ω range Measurement current: 0.5 mA Detection of shorts of: ≥1 ms |
| Common Diode | Measurement voltage: At 0.5 mA: >2.8 V At open circuit: <4 V Measurement current: 0.5 mA Polarity: + on input A, - on COM |
| Capacitance (CAP) | Ranges: 50, 500 nF, 5, 50, 500 μF Full scale reading: 5000 counts Measurement current: 500 nA to 0.5 mA, increases with increasing ranges |
| Advanced Meter Functions | |
| Zero Set | Set actual value to reference |
| AutoHold (on A) | Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals |
| Fixed Decimal Point | Activated by using attenuation keys |
| Cursor Readout | |
| Sources | A, B |
| Single Vertical Line | Average, minimum and maximum readout Average, minimum, maximum and time from start of readout (in ROLL mode; instrument in HOLD) Minimum, maximum and time from start of readout (in RECORDER mode; instrument in HOLD) Harmonics values in POWER QUALITY mode |
| Dual Vertical Lines | Peak-peak, time distance and reciprocal time distance readout Average, minimum, maximum and time distance readout (in ROLL mode; instrument in HOLD) |
| Dual Horizontal Lines | High, low and peak-peak readout |
| Rise or Fall Time | Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode) |
| Accuracy | As oscilloscope accuracy |
| Recorder | |
| Meter Readings | Measurement speed: Maximum 2 measurements Record size (minimum, maximum, average): 2 M readings for 1 channel Recorded time span: 2 weeks Maximum number of events: 1024 |
| Waveform Record | Maximum sample rate: 400 K samples Size internal memory: 400 M samples recorded time Span internal memory: 15 minutes at 500 μs/div - 11 hours at 20 ms/div Record size SD card: 1.5 G samples Recorded time span SD card: 11 hours at 500 μs/div - 14 days at 20 ms/div Maximum number of events: 64 |
| General Specifications | |
| Waveform Display | Vertical: 10 div of 40 pixels Horizontal: 12 div of 40 pixels |
| Maximum Input Voltage A and B | Direct on input or with leads: 600 Vrms CAT IV for derating With banana-to BNC adapter BB120: 600 Vrms for derating Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz |
| Display | Type: 5.7" color active martrix TFT Resolution: 640 x 480 |
| Interface | Optically isolated: Transfer screen copies (bitmaps), settings and data USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows® |
| Wireless Radio with Adapter | Frequency range: 2412 to 2462 MHz Output power: <100 mW |
| Environmental | MIL-PRF-28800F, Class 2 |
| Temperature | Battery operation: 32 to 104°F (0 to 40°C) Power adapter operation: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) non-condensing |
| Humidity (Operating) | At 32 to 50°F (0 to 10°C): non-condensing At 50 to 86°F (10 to 30°C): 95% At 86 to 104°F (30 to 40°C): 75% At 104 to 122°F (40 to 50°C): 45% |
| Altitude | Operating at 10,000' (3 km): CAT III 600 V Operating at 6600' (2 km): CAT IV 600 V Storage: 40,000' (12 km) |
| EMC Electromagnetic Compatibility | USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103) |
| Enclosure Protection | IP51, ref: EN/IEC60529 |
| Safety | General: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V |
| Memory | Internal memory can store 20 data sets (screen waveform and setup) Micro SD card slot with optional SD card (maximum size of 32 GB) |
| Power | External: Via power adapter BC430 Input voltage: 10 to 21 V DC Consumption: 5 W typical Input connector: 5 mm jack Internal: Via battery pack BP290 Battery power: Rechargeable Li-Ion 10.8 V Operating time: 7 hours with 50 % backlight brightness Charging time: 4 hours with test tool off, 7 hours with test tool on Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging |
| Dimensions | 10.2 x 5.2 x 2.15" (259 x 132 x 55 mm) |
| Weight | 3.2 lbs (1.4 kg) including battery pack |
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.