Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz

No reviews yet Write a Review
$4,950.38
SKU:
1630-2 FC
Availability:
1 in Stock
5 customers are viewing this product

Fluke 1630-2 FC Earth Ground Clamp, 1000 V, 40 Hz to 1 kHz

$4,950.38

Availability: 1 in Stock

Fluke 1630-2 FC Offers

Eliminate the hazardous and time-consuming process of disconnecting parallel grounds with this earth-ground clamp capable of stakeless measurement. Additionally, this clamp saves time by recording and storing up to 32,760 measured values in memory at the set logging interval.

Features

  • Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes
  • AC leakage current measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system–ideal for system troubleshooting
  • Rugged: Heavy-duty clamp jaw stays in alignment and calibration even in every day, on-the-job industrial environments
  • Alarm threshold: User-defined high/low alarm limits, for rapid measurement evaluation
  • Band-pass filter: Selectable band-pass filter function removes unwanted noise from the ac leakage current measurement

Logging measurements

  • The earth ground clamp saves time by automatically recording data at pre-set intervals
  • Saves up to 32,760 measurements in memory at the set logging interval
  • Saves time by recording and storing measured values

Wireless system

  • Connects the clamp with an app on your smartphone or tablet
  • You can save these measurements, and images to cloud storage and share with your team
  • Maximize uptime and make confident maintenance decisions with data you can trust and trace
  • Access baseline, historical and current measurements by asset
  • Share your measurement data using video calls and emails

Stakeless measurement

The clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes. With this test method, a two-process measurement is made around the earth ground wire or bus bar using the specially-designed jaw of the clamp. Auxiliary test stakes are not used at all. A known voltage is induced by the source in the clamp, and the current is measured by the sensor in the clamp. The tester automatically determines the earth loop resistance for this section of the earthing system.



Fluke 1630-2 FC Specifications

Specifications

Maximum Voltage to Earth Ground1000 V
Frequency Range40 Hz to 1 kHz
Ingress ProtectionIEC/EN 60529: IP30 with jaw closed
LCDDigital reading: 9999 countsRefresh rate: 4/s
Overload IndicationOL
Display Reading Specification with Loop Resistance StandardInput: 0.474 Ω, Minimum: 0.417, Maximum: 0.531Input: 0.5 Ω, Minimum: 0.443, Maximum: 0.558Input: 10 Ω, Minimum: 9.55, Maximum: 10.45Input: 100 Ω, Minimum: 96, Maximum: 104
Data LoggingCapacity: Minimum of 32,760 measurementsInterval: 1 second to 59 minutes and 59 seconds
Wireless RadioFrequency range: 2412 to 2462 MHzOutput power: <10 mWRadio frequency certification: FCC ID:T68-FBLE IC:6627A-FBLE
SafetyGeneral: IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1Measurement: IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current Clamp for Leakage Current MeasurementsIEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to EarthIEC/EN 61557-5
Effectiveness of The Protective MeasuresIEC/EN 61557-16: cutoff frequency 20 kHz (-3 dB)
Electromagnetic Compatibility (EMC)International: IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment)USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Conductor Size1.57" (40 mm) approximately
TemperatureOperating: 14 to 122°F (-10 to 50°C)Storage: -4 to 140°F (-20 to 60°C)Reference: 73°F ±9°F (23°C ±5°C)Coefficient: 0.15% X (specified accuracy)/°C (<64.4°F or >82.4°F [<18°C or >28°C])
Operating HumidityNon condensing: <50°F (<10°C)≤90% RH at 50 to 86°F (10 to 30°C)≤75% RH at 86 to 104°F (30 to 40°C)≤45% RH at 104 to 122°F (40 to 50°C) (Non condensing)
AltitudeOperating: 6561' (2000 m)Storage: 39370' (12,000 m)
BatteryType: 4 x 1.5 V AA alkaline IEC/EN LR6Life: More than 15 hours (In ground resistance measurement mode, with backlight turned off, and RF mode turned off)
Dimensions11.1 x 4.1 x 1.9" (283 x 105 x 48 mm)
Weight31 oz (880 g)


What's included with the Fluke 1630-2 FC
  • Earth Ground Clamp
  • Loop Resistance Standard
  • Hard Case
  • 4 x AA Batteries
  • Safety Information Guide
  • Quick Reference Guide
  • One-Year Warranty
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns