Features
Applications
Automatic measurements. More flexibility. Better power quality troubleshooting
The three-phase power quality analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series s automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord. With the 1770 Series youÂll never miss a critical power quality eventÂfrom fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.
Automatic measurement capture
Whether youÂre performing a quick system check or a detailed power quality study, consistent data is key. The power quality analyzer s a unique automatic measurement capture system that helps ensure youÂre collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system youÂre working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.
Ultimate measurement confidence
The three-phase power quality analyzers are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzerÂin a single, easy-to-use, handheld device.
The ÂPQ Meter function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ÂPQ Logging and Analysis function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring youÂre capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurementÂeven if you were unsure about what to look for when you started.
View real-time voltage transitory events while logging for faster troubleshooting High-speed voltage transient capture
Transients negatively impact otherwise healthy systems every day and their potential to damage your equipment canÂt be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The 1775 and 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the 1777 Power Quality Analyzer has 20 MHz sampling capability to capture the fastest transients in high detail.
A full range of harmonics are available from the first 50 integer harmonics and from 2 kHz to 30 kHz From traditional industrial systems to renewable energy systems to electric vehicles, weÂve got you covered
The three-phase power quality analyzer was designed to be safe and easy to use in any measurement environment. The three-phase power quality analyzer allows you to capture a full range of power quality variables as well as high-speed waveforms, high-speed transients, and higher frequency harmonics, all of which are instantly viewable on the large, high-resolution screen. With a best-in-class CAT IV 600 V / CAT III 1000 V overvoltage rating, these analyzers can be used at the service entrance or downstream, measuring AC and DC inputs, and harmonics measuring up to 30 kHz. With the 1770 Series you can be confident that youÂll capture the data you need to make better maintenance decisions no matter the task.
Easily navigate using the large color touchscreen Work where, when, and how you want
No two days in the field are the same. You need a power quality analyzer that can go where you go and do what you need it to when you get there. With a full range of accessories and built-in features the 1770 Series makes it easier to get your job done. The slim ergonomic design and integrated hand strap make it easy to hold and the included hanging kit makes it easy to secure your analyzer inside a cabinet. The integrated internal power supply allows the unit to be powered directly from the measured circuit, while a 90-minute battery helps ensure you can still access and review data even when you arenÂt connected to a live system.
Quickly and easily transfer data to your PC using the USB C, USB A, Ethernet, WiFi, cellular network support options, depending on your requirements. With an internal GPS module and an optional double insulated external antenna, you can time sync your data for more accurate troubleshooting and analysis.
Individual harmonics can be easily selected to view trend data as loads change Calculate current harmonics limits
When downloading data from the 1770 Series Power Quality Analyzers the included Energy Analyze Plus software package can compare measured voltage and current harmonic statistical data to different standards, like EN 50160 or IEEE 519, to determine if they exceed compliance limits. This powerful predictive maintenance feature enables current harmonics to be observed before distortion appears in the voltage allowing you to prevent unexpected failures or non-compliance situations and increase system uptime. With the proliferation of inverter-based loads and power generation, keeping current harmonics in check is becoming increasingly critical to ensure reliable power quality and avoid system downtime.
| Voltage Inputs | |
| Number of Inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
| Measurement Category | 1000 V CAT III/600 V CAT IV |
| Maximum Input Voltage | 1000 V rms/1000 V DC (1700 Vpk) |
| Nominal Voltage Range | Wye and single phase: variable (50 to 1000 V) Delta: variable (100 to 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 to 690 V |
| Input Impedance | 10 M? between P-P and P-N, 5 M? between P-PE and N-PE |
| Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |
| Resolution | 24-bit synchronous sampling |
| Sampling Frequency | 80 kS/second at 50/60 Hz |
| Scaling | 1:1, variable for use of potential transformers |
| Voltage Transients | |
| Measurement Range | ±8 kV |
| Bandwidth | DC to 1 MHz |
| Trigger | Adjustable trigger level Triggers on high-frequency components >1.5 kHz |
| Resolution | 14-bit synchronous sampling |
| Current Inputs | |
| Current Inputs | 4 inputs 3 phases and neutral, range selected automatically to attached sensor |
| Bandwidth | DC to 30 kHz |
| Resolution | 24-bit synchronous sampling |
| Sampling Frequency | 80 kS/second at 50/60 Hz |
| Scaling | 1:1 variable |
| Input Voltage | Clamp: 50 mV/500 mV rms; CF 2.8 Rogowski coil: 15 mV/150 mV rms at 50 Hz, 18 mV/180 mV rms at 60 Hz; CF 4 All at nominal probe range |
| Input Impedance | 11 k? |
| Data Acquisition Voltage and Current | |
| Input Mains Frequency | DC, 50/60 Hz ±15% (42.5 to 57.5 Hz, 51 to 69 Hz) |
| Topologies | 1-?, 1-? IT, split phase, 3-? delta, 3-? wye IT, 3-? aron/blondel (2 element delta), 3-? delta open leg, 3-? high leg delta |
| Data Storage | 8 GB internal |
| Memory Size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events The number of possible logging sessions and logging period depends on user requirements |
| Real-time Accuracy | Internal: 3 ppm (0.26 seconds per day, 8 seconds per month) NTP (internet time): depending on internet latency, typical <0.1 seconds absolute to UTC GPS: <1 ms absolute to UTC |
| General | |
| Dimensions | 11.0 x 7.5 x 2.4" (28 x 19 x 6.2 cm) |
| Weight | 4.6 lbs (2.1 kg) |
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.