Make data capture as reliable and easy as possible with the power quality analyzer that features instrument powering from the measurement circuit, automatic connection check, and correction.
The 1775 Power Quality Analyzer replaces the discontinued 435-II Power Quality and Energy Analyzer
Features
Applications
Automatic measurements. More flexibility. Better power quality troubleshooting
The three-phase power quality analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series s automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord. With the 1770 Series youÂll never miss a critical power quality eventÂfrom fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.
Automatic measurement capture
Whether youÂre performing a quick system check or a detailed power quality study, consistent data is key. The power quality analyzer s a unique automatic measurement capture system that helps ensure youÂre collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system youÂre working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.
Ultimate measurement confidence
The three-phase power quality analyzers are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzerÂin a single, easy-to-use, handheld device.
The ÂPQ Meter function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ÂPQ Logging and Analysis function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring youÂre capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurementÂeven if you were unsure about what to look for when you started.
High-speed voltage transient capture
Transients negatively impact otherwise healthy systems every day and their potential to damage your equipment canÂt be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The 1775 and 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the 1777 Power Quality Analyzer has 20 MHz sampling capability to capture the fastest transients in high detail.
From traditional industrial systems to renewable energy systems to electric vehicles, weÂve got you covered
The three-phase power quality analyzer was designed to be safe and easy to use in any measurement environment. The three-phase power quality analyzer allows you to capture a full range of power quality variables as well as high-speed waveforms, high-speed transients, and higher frequency harmonics, all of which are instantly viewable on the large, high-resolution screen. With a best-in-class CAT IV 600 V / CAT III 1000 V overvoltage rating, these analyzers can be used at the service entrance or downstream, measuring AC and DC inputs, and harmonics measuring up to 30 kHz. With the 1770 Series you can be confident that youÂll capture the data you need to make better maintenance decisions no matter the task.
Work where, when, and how you want
No two days in the field are the same. You need a power quality analyzer that can go where you go and do what you need it to when you get there. With a full range of accessories and built-in features the 1770 Series makes it easier to get your job done. The slim ergonomic design and integrated hand strap make it easy to hold and the included hanging kit makes it easy to secure your analyzer inside a cabinet. The integrated internal power supply allows the unit to be powered directly from the measured circuit, while a 90-minute battery helps ensure you can still access and review data even when you arenÂt connected to a live system.
Quickly and easily transfer data to your PC using the USB C, USB A, Ethernet, WiFi, cellular network support options, depending on your requirements. With an internal GPS module and an optional double insulated external antenna, you can time sync your data for more accurate troubleshooting and analysis.
Calculate current harmonics limits
When downloading data from the 1770 Series Power Quality Analyzers the included Energy Analyze Plus software package can compare measured voltage and current harmonic statistical data to different standards, like EN 50160 or IEEE 519, to determine if they exceed compliance limits. This powerful predictive maintenance feature enables current harmonics to be observed before distortion appears in the voltage allowing you to prevent unexpected failures or non-compliance situations and increase system uptime. With the proliferation of inverter-based loads and power generation, keeping current harmonics in check is becoming increasingly critical to ensure reliable power quality and avoid system downtime.
Voltage Inputs | |
Number of Inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
Measurement Category | 1000 V CAT III/600 V CAT IV |
Maximum Input Voltage | 1000 V rms/1000 V DC (1700 Vpk) |
Nominal Voltage Range | Wye and single phase: variable (50 to 1000 V) Delta: variable (100 to 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 to 690 V |
Input Impedance | 10 M? between P-P and P-N, 5 M? between P-PE and N-PE |
Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |
Resolution | 24-bit synchronous sampling |
Sampling Frequency | 80 kS/second at 50/60 Hz |
Scaling | 1:1, variable for use of potential transformers |
Voltage Transients | |
Measurement Range | ±8 kV |
Bandwidth | DC to 1 MHz |
Trigger | Adjustable trigger level Triggers on high-frequency components >1.5 kHz |
Resolution | 14-bit synchronous sampling |
Current Inputs | |
Current Inputs | 4 inputs 3 phases and neutral, range selected automatically to attached sensor |
Bandwidth | DC to 30 kHz |
Resolution | 24-bit synchronous sampling |
Sampling Frequency | 80 kS/second at 50/60 Hz |
Scaling | 1:1 variable |
Input Voltage | Clamp: 50 mV/500 mV rms; CF 2.8 Rogowski coil: 15 mV/150 mV rms at 50 Hz, 18 mV/180 mV rms at 60 Hz; CF 4 All at nominal probe range |
Input Impedance | 11 k? |
Data Acquisition Voltage and Current | |
Input Mains Frequency | DC, 50/60 Hz ±15% (42.5 to 57.5 Hz, 51 to 69 Hz) |
Topologies | 1-?, 1-? IT, split phase, 3-? delta, 3-? wye IT, 3-? aron/blondel (2 element delta), 3-? delta open leg, 3-? high leg delta |
Data Storage | 8 GB internal |
Memory Size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events The number of possible logging sessions and logging period depends on user requirements |
Real-time Accuracy | Internal: 3 ppm (0.26 seconds per day, 8 seconds per month) NTP (internet time): depending on internet latency, typical <0.1 seconds absolute to UTC GPS: <1 ms absolute to UTC |
General | |
Dimensions | 11.0 x 7.5 x 2.4" (28 x 19 x 6.2 cm) |
Weight | 4.6 lbs (2.1 kg) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)