null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

Fluke FLUKE-117/PRV240 Digital Multimeter and Proving Unit Kit

No reviews yet Write a Review
$675.00
SKU:
FLUKE-117/PRV240
Availability:
5 to 6 Weeks
5 customers are viewing this product

Fluke FLUKE-117/PRV240 Digital Multimeter and Proving Unit Kit

$675.00

Availability: 5 to 6 Weeks

Fluke 117/PRV240 Offers

The digital multimeter includes integrated non-contact voltage detection to help get the job done faster

Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.

Engineered and tested with your safety on the job in mind

Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.

Features

  • VoltAlert™ technology for non-contact voltage detection
  • AutoVolt automatic ac/dc voltage selection
  • LoZ: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True-rms for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30 seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/max/average to record signal fluctuations
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • Accurate and easy-to-use
  • Provides low input impedance to help prevent false readings due to ghost voltage
  • CAT III 600 V safety rated

Applications

  • Commercial buildings
  • Hospitals
  • Schools

Fluke PRV240 Proving Unit

Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.

Features

  • Sources both AC and DC steady-state voltage - supplies 240 V DC/AC
  • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
  • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
  • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
  • Long battery life - 5000 tests per set of four AA batteries

Test before touch

Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of "Test Before Touch" (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.

Designed for safety and compliance

Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.

Applications

  • Test and measurement


Fluke FLUKE-117/PRV240 Specifications

Specifications

Multimeter
DC millivoltsRange: 600.0 mV Resolution: 0.1 mV Accuracy: ±0.5% of reading + 2 counts
DC VoltsRange: 6.000 V, 60.00 V, 600.0 V Resolution: 0.001 V, 0.01 V, 0.1 V
Accuracy±0.5% of reading + 2 counts
ContinuityRange: 600 Ω Resolution: 1 Ω Accuracy: Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer Maximum voltage between any terminal and earth ground: 600 V
Surge Protection6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A Input11 A, 1000 V FAST Fuse
DisplayDigital: 6000 counts, updates 4/sec
Bar Graph33 segments, updates 32/sec
TemperatureOperating: 14 to 122°F (-10 to 50°C) Storage: -40 to 140°F (-40 to 60°C)
Proving Unit
Output Voltage: 240 V AC RMS or DC±10 % ≥1 MΩ
Output Voltage: LoZ >3 kΩ load60 V AC typical; 50 V AC RMS minimum
LED Power IndicatorTurns on when output voltage is present
Battery4 x AA Alkaline batteries NEDA (24 A IEC LR03)
Battery Life5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating Temperature14 to 122°F (-10 to 50°C)
Operating Humidity0 to 90% (0 to 35°C)
Operating Altitude6561.68' (2000 m)
SafetyIEC61010-1, IEC61010-2-030
CertificationCSA-CUS, CE
Dimensions4.6 x 2.9 x 1.1" (11.7 x 7.4 x 2.8 cm)
Weight8 oz (0.23 kg) includes batteries


What's included with the Fluke FLUKE-117/PRV240
  • Digital Multimeter
  • Proving Unit
  • Test Lead Set
  • Holster
  • TPAK Hanging Strap
  • 9 V Alkaline Battery (installed)
  • 4 x AA Batteries
  • User Manual
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns