Fluke Networks DSX2-5000 Offers

Accurate and easy to use, this copper cable certifier complies with all standards making jobs effortless and getting to system acceptance faster. Additionally, individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Features

  • Accelerates every step of the copper certification process
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Unmatched speed for CAT 6A, 8, Class FA, I/II and all current standards
  • Taptive™ user interface simplifies set-up, and eliminates errors
  • Analyze test results and create professional test reports using LinkWare™ management software

Unique features

  • Versiv™ enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • Reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Standards

  • Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
  • TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
  • Screen continuity along path of cabling

Performance

  • Eight second CAT 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 CAT 6A test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • Integrated Wi-Fi allows you to easily upload results to LinkWare™ Live
  • Over 1 billion links reported on LinkWare PC management software

Versiv platform is ready for today's and tomorrow's jobs

Electrically centered plug design is compliant with TIA Level 2G and IEC Level VI accuracy requirements to 2000 MHz with a future-ready design to support all hardware upgrades. Enables cable testing and certification for network deployments up to 40 Gigabit Ethernet – whether it is an existing CAT 5e, 6, 6A, 8 or Class I/II cabling system, tests to all industry standards. The electrically centered test plug results in the Level 2G/VI accuracy required to support field testing to CAT 8 / Class I/II, 2000 MHz. Exceeds the IEC Level VI and TIA Level 2G specifications assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like CAT 8 require more precise measurement to ensure they are providing the noise immunity required by 25G and 40G applications. Additionally, complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module up to 40GBASE-T testing. The first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, a key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property due to the higher level of electromagnetic interference (EMI) within the industrial environment. The Unit has obtained Intertek (ETL) verification in accordance with the ANSI/TIA-1152-A specification for Level 2G test equipment.

ProjX management system manages complex jobs with ease

Manage up to 12,000 CAT 6A test results with full graphics. Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The ProjX management system on the unit provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0 to 100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.

Taptive user interface simplifies set up, eliminates errors and speeds troubleshooting

Capacitive touchscreen allows quick tester setup and supports all standards. Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you’re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the configuration making correct testing assured.

Performs with unsurpassed speed

Eight second CAT 6A test time and the fastest way to submit your certification results. No tester offers so much speed for so many tests. Complete copper certification to CAT 6A in eight seconds or certify two fibers at two wavelengths in just three seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Troubleshoot like an expert

Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting. Reduces the time required to fix cabling faults with dedicated diagnostics, a simple one button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the unit removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

MPTL certification

There may be scenarios where a typical four-connector channel is not used when connecting these types of devices - especially those that reside in the ceiling space where it is impractical to install a faceplate. Instead, there is just one patch cord in the telecommunications room and the permanent link is terminated at the other end with a plug so it can plug directly into the device, essentially eliminating the equipment cord. This creates what is now known as a Modular Plug Terminated Link, or MPTL. The unit is capable of certifying MPTL by using a patch cord adapter on one end and a permanent link on the opposite end. The patch cord adapters support Category 5e, 6, and 6A performance levels. The latest version of the Versiv/DSX firmware is required to use the MPTL testing limits. Shield continuity historically is a direct current (DC) measurement with no distance to fault available. Other testers run a simple resistance test to verify that the shield has continuity. These tests have been shown to be inaccurate, sometime confusing a ground path as shield continuity and not correctly identifying a break in the shield. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework. The unit is the first field tester to report distance to any shield integrity issues, reporting the true status of the screen continuity. This is especially important in datacenters and CAT 8 installations where screen continuity is critical to maintaining alien crosstalk performance of screened cabling.

Applications

  • Copper certification


Fluke Networks DSX2-5000 Specifications

Specifications

Test TimeCAT 6A / Class EA: 10 secondsHDTDX/HDTDR Diagnostic: Approximately 3 secondsAutotest: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of CAT 6A/Class EA: 10 seconds
Internal MemoryApproximately 12,000 CAT 6A with plots
>Level V Accuracy (1 GHz)Yes
Shield Integrity Check and Distance to FaultYes
MeasurementsResistance unbalance: YesTCL: YesELTCTL: YesCDNEXT: YesCMRL: Yes
Built-in Alien XTalk CapabilityYes
AdapterChannel: 1 GHz rangePermanent link: 1 GHz range
Cable TypesShielded and unshielded pair LAN cabling: TIA CAT 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 and 120 Ω
Standard Link Interface AdaptersPermanent link adapters:Plug type: shielded RJ45Optional Plug type: ARJ45/GG45Channel adapters:Jack type: shielded RJ45Optional jack type: Tera, GG45/ARJ45
Test StandardsTIA: CAT 3, 4, 5, 5e, 6, 6A, 8 per TIA 568 SeriesISO/IEC: Class C, D, E, EA, F, FA, I/II certification per ISO/IEC 11801 SeriesMaximum frequency: 1000 MHz
Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests)Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-tocrosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input ProtectionProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display5.7" (14.47 cm) LCD display with a projected capacitance touchscreen
CaseHigh impact plastic with show absorbing overmold
CalibrationService center calibration period is 1 year
Integrated Wi-FiMeets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
PowerMain unit and remote: Lithium ion battery pack, 7.2 VTypical battery life: 8 hoursCharge time: Tester off: 4 hours to charge from 10 to 90% capacity
DimensionsMain Versiv unit with DSX module and battery installed: 2.625 x 5.25 x 11" (6.67 x 13.33 x 27.94 cm)
WeightMain Versiv unit with DSX module and battery installed: 3 lbs (1.28 kg)


What's included with the Fluke Networks DSX2-5000
  • Mainframe and Remote
  • 2 x Cable Analyzer Modules
  • Set of Permanent Link Adapters
  • Set of Channel Adapters
  • 2 x Headsets
  • 2 x Hand Straps
  • 2 x Shoulder Straps
  • USB Interface Cable
  • 2 x AC Chargers
  • 2 x Universal Couplers
  • Carrying Case
  • Getting Started Guide
  • 90-Day Warranty
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns