Guaranteed Fitment
Always the correct part
have questions?
Always the correct part
We know our products
Fast & Reliable
Availability: 1 to 2 Weeks
Fluke Networks 19800009 OffersThe Fluke Networks TS19 Test Set combines all the essential test set features at an affordable price. This test set was specifically designed for in-house telecom technicians. Its high impedance monitor prevents accidental disruption of service from clipping onto a data line while in monitor mode, thus ensuring the integrity of critical data lines. Features such as tone (DTMF) or pulse operation, talk/monitor capabilities, polarity test button and last number redial make this test set the perfect combination of features and price.
Loop Limit
2.4 kΩmaximum at 48 VDC (nominal 15 mA minimum loopcurrent)
DC Resistance (Talk Mode)
150 Ωtypical at 80 mA current
AC Impedance (Monitor Mode)
Low impedance (Ring position) 600 Ωat 1 KHz typical High impedance (HI Z position) 100 kΩminimum at 1 KHz
Rotary Dial Output
10 pps .5 pps
Interdigit Interval Leakage During Break
> 50 kΩ
DTMF Output
±1 % maximum
Tone Frequency Error Level per Tone Pair
dBm maximum, - dBm minimum
High versus Low Tone Difference
4 dB maximum
Length
8.75 in (22.2 cm)
Width
2.375 in (6.03 cm)
Height
3.375 in (8.57 cm)
Weight
10.8 oz (.307 kg) maximum
Temperature
Operating: -5 °C to °C Storage: -40 °C to °C
Drop
1 meter, 4 times
Altitude
To 3,000 meters (10,000 feet) maximum
Relative Humidity
10 %to 80 % (non-condensing)
Regulatory Standards Used
Certifications and Compliance
Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1
Electrical | |
Loop Limit | 2.4 kΩmaximum at 48 VDC (nominal 15 mA minimum loopcurrent) |
DC Resistance (Talk Mode) | 150 Ωtypical at 80 mA current |
AC Impedance (Monitor Mode) | Low impedance (Ring position) 600 Ωat 1 KHz typical High impedance (HI Z position) 100 kΩminimum at 1 KHz |
Rotary Dial Output | 10 pps .5 pps |
Pulsing Rate | 60 % ± 2 % |
Percent Break | 800 ms typical |
Interdigit Interval Leakage During Break | > 50 kΩ |
DTMF Output | ±1 % maximum |
Tone Frequency Error Level per Tone Pair | dBm maximum, - dBm minimum |
High versus Low Tone Difference | 4 dB maximum |
Physical | |
Length | 8.75 in (22.2 cm) |
Width | 2.375 in (6.03 cm) |
Height | 3.375 in (8.57 cm) |
Weight | 10.8 oz (.307 kg) maximum |
Environmental | |
Temperature | Operating: -5 °C to °C Storage: -40 °C to °C |
Drop | 1 meter, 4 times |
Altitude | To 3,000 meters (10,000 feet) maximum |
Relative Humidity | 10 %to 80 % (non-condensing) |
Regulatory Standards Used | 47 CFR Part 15, Subpart B ICES-003 Issue 3 AS/NZS 3548 EMC Directive 89/336/EEC, EN 55022:98, EN 61326:97, A1:98 Annex C, EN 61000-4-2, EN 61000-4-3 LV Directive 73/23/EEC, EN 610010.1 (1993) |
Certifications and Compliance | Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.