Guaranteed Fitment
Always the correct part
have questions?
Always the correct part
We know our products
Fast & Reliable
Availability: 3 to 4 Weeks
Gossen Metrawatt M240O OffersWith its wide range of functions, this advanced multimeter is an ideal tool for many tasks and areas of work. Additionally, the ergonomic design ensures maximum ease of use and safety.
Features
Three connector jacks with automatic blocking sockets (ABS)
All current ranges are implemented via a single connector jack which prevents any possibility of operator error. Beyond this, the automatic blocking sockets prevent incorrect connection of the measurement cables, as well as selection of the wrong measured quantity. Danger to the user, the instrument and the device under test resulting from operator error is thus ruled out.
Overload protection
It is safeguarded for up to 1000 V in all measuring functions by overload protection. Voltages of greater than 1000 V and current of greater than 10 or 16 A are indicated acoustically. Dangerous contact voltages are indicated when the 1 kHz lowpass filter is activated. The FUSE display appears in order to indicate that the fuse for the current measuring input has blown.
RMS value with distorted waveshape
The utilized measuring method allows for waveshape independent RMS measurement (TRMS AC and AC+DC) for voltage and current (up to 20 kHz).
Activatable filter for V AC measurement
A 1 kHz low-pass filter can be activated if required, for example when measuring motor voltage at electronic frequency converters. The input signal is checked by a voltage comparator for dangerous voltages as long as the low-pass filter is activated.
Measuring 5 V square-wave signals
This function makes it possible to test circuits and transmission cables by measuring the frequency and the duty cycle of pulses with amplitudes of 2 to 5 V and frequencies of 100 Hz to 1 MHz.
Analog scale for quick trend display - bar graph or pointer
The analog scale (with additional negative range for zero frequency quantities) allows for faster recognition of measured value fluctuation than is possible with a digital display. It can be switched back and forth between bar graph and pointer display.
Automatic or manual measuring range selection
Measured quantities are selected by means of a rotary switch and a function key. The measuring range is automatically matched to the measured values. The measuring range can also be selected and fixed manually with a key.
Fast acoustic continuity test
Testing for short circuiting and interruption is possible with the selector switch. The threshold value for acoustic signaling can be set to 1, 10, 20, 30, 40 or 90 Ω.
Automatic storage of measured values
The DATA function automatically saves the digitally displayed measured value after settling in. Acoustic signaling is also used to indicate whether the new measured value deviates from the initial reference value by less or more than 0.1% of the measuring range.
Storage of minimum/maximum values
Comparable to the slave-pointer function of an analog instrument, this multimeter saves the highest and lowest measured values after the MIN/MAX function has been activated or reset. These extreme values can be queried at the display.
Battery charging status - power saving circuit
The battery charging status is indicated by means of four symbols. This multimeter is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable), and if none of the controls are activated during this time. Automatic shutdown can be deactivated by switching it to continuous operation. The infrared interface can be switched off in the standby mode.
Protective cover for harsh conditions
This multimeter is protected against damage in the event of impacts or dropping by means of a soft rubber cover with tilt stand and test probe holder. The rubber material also assures that it does not wander if it is set up on a vibrating surface.
Infrared data interface
This multimeter can be remote configured, and momentary and stored measurement data can be read out via the bidirectional infrared interface. The USBX-TRA interface adapter and METRAwin 10 software are required to this end (sold separately).
Applications
Measuring Function: V | Range: 100 mV, 1, 10, 100, 1000 V Resolution (at upper range limit): 10, 100 μV, 1, 10, 100 mV |
Measuring Function: A | Range: 100 μA, 1, 10, 100, 1000 mA Resolution (at upper range limit): 10, 100 nA, 1, 10 μA |
Measuring Function: Ω | Range: 100 Ω, 1, 10, 100 kΩ, 1, 10, 40 MΩ Resolution (at upper range limit): 10, 100 mΩ, 1, 10, 100 Ω, 1, 10 kΩ |
Measuring Function: F | Range: 100 Ω, 1, 10, 100 kΩ, 1, 10, 40 MΩ Resolution (at upper range limit): 10, 100 mΩ, 1, 10, 100 Ω, 1, 10 kΩ |
Internal Clock | Time format: DD.MM.YYYY hh:mm:ss Resolution: 0.1 s Accuracy: ±1 min/month Temperature: Influence 50 ppm/K |
Reference Conditions | Ambient temperature: 23°C ±2 K Relative humidity: 40 to 75% Measured quantity frequency: 45 to 65 Hz Measured quantity waveshape: Sine Battery voltage: 3 V ±0.1 V |
Data Interface | Type: Optical via infrared light through the housing Data transmission: Serial, bidirectional (not IrDa compatible) Protocol: Device specific Baud rate: 38,400 baud Functions: Select/query measuring functions and parameters, query momentary measurement data, read out stored measurement data |
Internal Measured Value Storage | Memory capacity: 4 MBit/540 kB for approximately 15,400 measured values with date and time stamp |
Acoustic Signals | For voltage: Intermittent signal at above 1000 V For current: Intermittent signal at above 10 A, continuous signal at above 16 A |
Fuse | FF (UR) 10 A/1000 V AC/DC; 0.4 x 1.5" (10 x 38 mm) Switching capacity: 30 kA at 1000 V AC/DC, protects the current measurement input in the 100 μA through 10 A ranges |
Display | LCD panel (2.6 x 1.4" [65 x 36 mm]) with analog and digital display including unit of measure, type of current and various special functions |
Electrical Safety | Per IEC 61010-1:2010/VDE 0411-1:2011 Safety class: II Measuring category: III and IV Operating voltage: 1000 V and 600 V Pollution degree: 2 Test voltage: 6.7 kV~ |
Electromagnetic Compatibility (EMC) | Interference emission: EN 61326-1: 2013, class B Interference immunity: EN 61326-1: 2013, EN 61326-2-1: 2013 |
Ambient Conditions | Accuracy range: 32 to 104°F (0 to 40°C) Operating temperature: 14 to 122°F (-10 to 50°C) Storage temperature: -13 to 158°F (-25 to 70°C), without batteries Relative humidity: 40 to 75%, maximum 96%, no condensation allowed Elevation: To 6561.68' (2000 m) Deployment: Indoors, except within specified ambient conditions |
Power Supply | Battery type: 2 x 1.5 V mignon cell (2 x AA), alkaline manganese per IEC LR6 (2 x 1.2 V NiMH rechargeable battery also possible) Battery life: With alkaline manganese: approximately 200 hours |
Protection | Housing: IP65 |
Housing | Impact resistant plastic (ABS) |
Dimensions | 7.87 x 3.43 x 1.77" (200 x 87 x 45 mm), without protective rubber cover |
Weight | Approximately 0.77 lbs (0.35 kg) with batteries |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.