Gossen Metrawatt SECULIFE HIT AM OffersWork with this rugged TRMS medical multimeter that has a data capacity for more than 15,000 measured values and is resistant to dust and water.
Features
SECULIFE HIT AM
The multimeters of the SECULIFE HIT AM series have been endowed with antimicrobial properties. This is to curb the growth of germs, counteract microbial colonization or kill microorganisms.
Three connector jacks with automatic blocking sockets (ABS)
All current ranges are implemented via a single connector jack which prevents any possibility of operator error. Beyond this, the automatic blocking sockets prevent incorrect connection of the measurement cables, as well as a selection of the wrong measured quantity. Danger to the user, the instrument, and the device under test resulting from operator error is thus ruled out.
Overload protection
This instrument is safeguarded for up to 1000 V in all measuring functions by overload protection. Voltages of greater than 1000 V and a current of greater than 10 or 16 A are indicated acoustically. Dangerous contact voltages are indicated when the 1 kHz lowpass filter is activated. The FUSE display appears to indicate that the fuse for the current measuring input has blown.
RMS value with distorted waveshape
The utilized measuring method allows for waveshape independent RMS measurement (TRMS AC and AC+DC) for voltage and current up to 20 kHz.
Activatable filter for V AC measurement
A 1 kHz low-pass filter can be activated if required, for example when measuring at electronic frequency converters or switched-mode power supplies.
High voltage sensor
The input signal is examined for contact danger regardless of the selected input function or filtering.
Measuring 5 V square-wave signals
This function makes it possible to test circuits and transmission cables by measuring the frequency and the keying ratio of pulses with amplitudes of 2 to 5 V and frequencies of 100 Hz to 1 MHz.
Analog scale for quick trend display – bar graph or pointer
The analog scale (with an additional negative range for zero-frequency quantities) allows for faster recognition of measured value fluctuation than is possible with a digital display. This instrument can be switched back and forth between the bar graph and pointer display.
Automatic or manual measuring range selection
Measured quantities are selected using a rotary switch and a function key. The measuring range is automatically matched to the measured values. The measuring range can also be selected and fixed manually with a key.
Fast acoustic continuity test
Testing for short-circuiting and interruption is possible with the selector switch in the position. The threshold value for acoustic signaling can be set to 1, 10, 20, 30, 40 or 90 Ω.
Automatic storage of measured values
The DATA function automatically saves the digitally displayed measured value after settling in. Acoustic signaling is also used to indicate whether the new measured value deviates from the initial reference value by less or more than 0.1% of the measuring range.
Storage of minimum to maximum values
Comparable to the slave-pointer function of an analog instrument, the device saves the highest and lowest measured values after the minimum/maximum function has been activated or reset. These extreme values can be queried at the display. The values are acquired using an especially fast sampling rate (40 measurements per second).
Battery charging status-power saving circuit
The battery charge level is indicated using a 4-segment symbol. This device is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable), and if none of the controls are activated during this time. The automatic shutdown can be deactivated by switching the instrument to continuous operation.
Protective cover for harsh conditions
This instrument is protected against damage in the event of impacts or dropping using a soft rubber cover with a tilt stand and test probe holder. The rubber material also assures that the instrument does not wander if it is set up on a vibrating surface.
Infrared data interface
This device can be remotely configured, and momentary and stored measurement data can be read out via the bidirectional infrared interface. The USB X-TRA interface adapter and METRAwin 10 software are required to this end (see accessories). Interface protocol and device driver software for LabVIEW® (National Instruments™) are available upon request. The infrared interface can be switched off in the standby mode.
DAkkS calibration certificate
This multimeters are furnished with an internationally valid DAkkS calibration certificate (recognized by EA and ILAC). After the specified calibration interval has elapsed (recommended interval: one to three years), the multimeters can be inexpensively recalibrated in our own DAkkS calibration laboratory.
Applications
Number of Multimeter Functions | 23 |
Bandwidth (TRMS) | 20 kHz |
Display | LCD panel (65 x 36 mm) with analog and digital display |
Accuracy Range | 32 to 104°F (0 to 40°C) |
Acoustic Signals | For voltage: Intermittent signal at above 1000 V For current: Intermittent signal at above 10 A continuous signal at above 16 A |
Memory Capacity | 4 MBit / 540 kB for approximately 15,400 measured values with date and time stamp |
Relative Humidity | Maximum 75%, no condensation allowed |
Elevation | To 6561.68' (2000 m) |
Deployment | Indoors, except within specified ambient conditions |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -13 to 158°F (-25 to 70°C), without batteries) Ambient: 73.4°F (23°C) ±2 K |
Housing | Impact resistant plastic (ABS) |
Power Supply | 2 x 1.5V AA batteries |
Dimensions | 7.87 x 3.42 x 1.77" (200 x 87 x 45 mm), without protective rubber cover |
Weight | Approximately 0.77 lbs (0.35 kg), with batteries |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.