Work with fast and accurate electrical measurements with this user-friendly and efficient meter, making it the perfect choice for any commercial or residential project. In addition, this meter features an adapter function, for easy use with external transducers or measurement devices.
Features
A range offering unprecedented analytical and diagnostic functions!
TRMS version of Min and Max: The Min and Max are TRMS values calculated over a duration of up to 100 ms. This feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc.
Peak+ and Peak-: Calculated over a period of 1 ms, the Peak+ and Peak- values help to characterize the distortion affecting the signal measured. For example, they may reveal variations in the installation's behavior or even malfunctions.
ΔREL, for quick evaluation: Comparison with a reference quantity is a quick way of evaluating and analyzing your results. A signal's variations can be measured differentially or relatively. The first method indicates the difference between the value of reference and the value measured. The second method indicates the proportion. The ΔRELfunction can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions
Feature rich clamp-on meter
Ideal tool for any work in the field and is simple to use and groups all the necessary functions in a single, compact solution. Leveraging cutting-edge technology, this meter guarantees top-notch quality while ensuring user-friendly simplicity.
Performance
Benefit from a fast 12-bit TRMS digital acquisition system offering high measurement accuracy. Thanks to it's large bandwidth and high crest factor, this clamp provides accurate measurements whatever the signal type.
Ergonomics
The entire range is designed for one-handed use, even when wearing safety gloves. For maximum efficiency, each measurement corresponds to a specific switch position. The one key, one function concept makes it even easier to use. In addition, this clamp is equipped with automatic detection of the type of signal (AC or DC) on currents, voltages, and power values.
True InRush® function
True InRush® function provides the unique ability to measure power-up events from devices on a network that is already energized. Unlike other instruments which only measure the inrush when the installation is first powered up, our power clamp-on meters measure all types of inrush, even those due to load increases on an installation which is already up and running.
Applications
| DC Voltage Measurement | Measurement range: 0 to 99.99 VSpecified measurement range: 0 to 1600 VAccuracy: 0 to 9.99 V ± (1% R + 10 cts)/10 to 99.99 V ± (1% R + 3 cts)Resolution: 0.01 VInput impedance: 10 MΩMeasurement range: 100 to 999.9 VSpecified measurement range: 0 to 1600 VResolution: 0.1 VInput impedance: 10 MΩMeasurement range: 1000 to 1700 V1)Specified measurement range: 0 to 1600 VResolution: 1 VInput impedance: 10 MΩ1)The display indicates +OL above 3400 V and -OL below - 3400 V, in REL mode. Above 1700 V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed.*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
| AC Voltage Measurement | Measurement range: 0.15 to 99.99 VSpecified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: 0.15 to 9.99 V ± (1% R+ 10 cts)/10 to 99.99 V ± (1% R + 3cts)Resolution: 0.01 VInput impedance: 10 MΩ100 to 999.9 VSpecified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: ± (1% R + 4 cts)Resolution 0.1 VInput impedance: 10 MΩMeasurement range: 1000 to 1200 V RMS/1700 V peak1)Specified measurement range2): 0 to 1100 V AC/1600 V peakAccuracy: ± (1% R + 4 cts)Resolution 1 VInput impedance: 10 MΩ1)The display indicates OL above 1700 V. Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed bandwidth in AC = 3 kHz.2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display.*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
| DC Current Measurement | Measurement range2): 0 to 99.99 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy (zero corrected)2): ± (1% R + 10 cts)Resolution: 0.01 AMeasurement range: 100 to 999.9 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy (zero corrected)2): (1% R + 3 cts)Resolution: 0.1 AMeasurement range: 1000 to 1500 A1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy (zero corrected)2):(1.5% R + 3 cts)Resolution: 1 A1)The display indicates +OL above 3000 A and -OL below -3000 A in REL mode. The - and + signs are displayed (polarity).2)The residual current at zero depends on the remanence, it can be corrected by the DC zero function of the HOLD button.*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
| AC Current Measurement | Measurement range2): 0.25 to 99.99 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.01 AMeasurement range2): 100 to 999.9 ASpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 3 cts)Resolution: 0.1 AMeasurement range2): 1000 A (15,000 A peak)1)Specified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 3 cts)Resolution: 1 A1)The display indicates OL above 1500 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 2 kHz.2)In AC, any value between zero and the min. threshold of the measurement range (0.25 A) is forced to show ----on the display*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
| True InRush Measurement | Measurement range: 10 A to 1000 A AC/10 A to 1500 A DCSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (5% R + 5 cts)Resolution: 1 APeak mode:Accuracy: Add ± (1.5% R + 0.5 A) to the values abovePeak capture time: 1 ms minimum to 1.5 ms maximum |
| Continuity Measurement | Measurement range: 0 to 999.9 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 550 μAAccuracy: ± (1% R + 5 cts)Buzzer triggering threshold: Adjustable from (1 to 999) Ω (40 Ω is the default) |
| Resistance Measurement | Measurement range1): 0 to 99.9 ΩSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.1 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 550 μAMeasurement range1): 100 to 999.9 ΩSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (1% R + 5 cts)Resolution: 0.1 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 500 μAMeasurement range1): 10 to 9999 kΩSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 5 cts)Resolution: 1 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 100 μAMeasurement range1): 10 to 99.99 kΩSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ± (1% R + 5 cts)Resolution: 10 ΩOpen-circuit voltage: ≤3.6 VMeasurement current: 10 μAMAX/MIN mode:Accuracy: add 1% R to the values aboveCapture of the extreme: Approximately 100 ms1)Above the maximum display value, the display unit indicates OL. The - and + signs are not displayed. |
| Diode Test | Measurement range: 0 to 3.199 V DCSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± (1% R + 10 cts)Resolution: 0.001 VMeasurement current: 0.55 mAIndication (junction reversed or open circuit): OL is displayed when the measured voltage >3.199 V |
| Frequency Voltage Measurement | Measurement range1): 5 to 999.9 HzSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ±0.4% R + 1 ctResolution: 0.1 HzMeasurement range1): 1000 to 9999 hZSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ±0.4% R + 1 ctResolution: 1 HzMeasurement range1): 10 to 19.99 kHzSpecified measurement range: 0 to 100% of the measurement rangeAccuracy: ±0.4% R + 1 ctResolution: 10 HzMAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values aboveCapture time of the extreme: Approximately 100 ms1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ---- |
| Frequency Current Measurement | Measurement range1): 5 to 999.9 HzSpecified measurement range: 1 to 100% of the measurement rangeAccuracy: ± 0.4% R + 1 ctResolution: 0.1 HzMAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values aboveCapture time of the extreme: Approximately 100 ms1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ---- |
| Temperature Measurement | Type of sensor K-thermocoupleMeasurement range: 76 to 1831.8°F (-60 to 999.9°C)/1832 to 2192°F (1000 to 1200°C)Specified measurement range: 1 to 100% of the measurement rangeAccuracy1): 1% R ±5.4°F (1% R ±3°C)Resolution: 0.1°F (0.1°C)MAX/MIN mode (10 Hz to 1 kHz):Accuracy: Add 1% R to the values aboveCapture time of the extreme: Approximately 100 ms1)The stated external temperature measurement accuracy does not take the accuracy of the K-thermocouple into account.*NOTE: Use of the thermal time constant (0.7 min/°C): If there is a sudden variation of the temperature of the clamp, by 50°F (10°C) for example, the clamp will be at 99% (cnst = 5) of the final temperature after 0.7 min/°C x 5 to 35 min (the time constant of the external sensor must be added to this value). |
| Adapter Function Measurement in DC Mode | Measurement range1): 0 to 999.9 mVSpecified measurement range2): 0 to 100% of the measurement rangeAccuracy: 1% R + 3 ctsResolution: 0.1 mVInput impedance: 10 MΩMeasurement range1): 1 to 9.99 VSpecified measurement range2): 0 to 100% of the measurement rangeAccuracy: 1% R + 3 ctsResolution: 10 mVInput impedance: 10 MΩMAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values aboveCapture of the extreme: Approximately 100 ms1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts.2)The maximum bandwidth is 1 kHz. |
| Adapter Function Measurement in AC Mode | Measurement range1): 5 to 999.9 mVSpecified measurement range2): 0 to 100% of the measurement rangeAccuracy: 5 to 99.9 mV ± 1% R + 10 cts/100 to 999.9 mV ± 1% R + 3 ctsResolution: 0.1 mVInput impedance: 10 MΩMeasurement range1): 1 to 9.99 VSpecified measurement range2): 0 to 100% of the measurement rangeAccuracy: 1% R + 3 ctsResolution: 10 mVInput impedance: 10 MΩMAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values aboveCapture of the extreme: Approximately 100 ms1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts.2)The maximum bandwidth is 1 kHz. |
| Screen | LCD unitBlue backlighting |
| Temperature | Operating: -4 to 131°F (-20 to 55°C)Storage: -40 to 158°F (-40 to 70°C) |
| Relative Humidity (RH) | Operating: ≤90% up to 131°F (55°C)Storage: ≤90% up to 158°F (70°C) |
| Power Supply | Batteries: 4 x 1.5 V AA LR6Battery life: >350 hours (without backlighting)Auto power off: After 10 minutes with no switch and/or button activity |
| Compliance with International Standards | Electric safety: Compliant with standards IEC/EN 61010-1 or BS EN 61010-1, IEC/EN 61010-2-032 or BS EN 61010-2-032: 1000 V CAT IV and 1500 V CAT IIIElectromagnetic compatibility: Compliant with standard EN-61326-1 or BS EN 61326-1, classification: residential environmentMechanical strength: Free fall: 3.28' (2 m), in accordance with standard IEC-68-2-32Level of protection: Housing IP54 (per standard IEC-60529)/Jaws: IP40 |
| Housing | Rigid polycarbonate shell with over-molded elastomer covering; UL94 V1 |
| Jaws | PolycarbonateOpening: 1.9" (48 mm)Clamping diameter: 1.9" (48 mm) |
| Dimensions | 10.7 x 3.6 x 1.6" (272 x 92 x 41 mm)Screen: 1.6 x 1.9" (41 x 48 mm) |
| Weight | 1.32 lbs (600 g) with the batteries |
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.