Hioki IM3533-01 LCR Meter
SKU: IM3533-01
Availability: 4 to 5 Weeks Hioki IM3533-01 Offers Features A single device can perform measurements at high speed undermultiple conditions.(C-D + ESR measurement and L + DCR measurement) Optimal measurement conditions can be set automatically accordingto the test sample so switching between setups is a snap. DCR temperature compensation (DCR temperature compensationfunction). All the measurements necessary to evaluate transformers (such asturn
Availability: 4 to 5 Weeks
Hioki IM3533-01 Offers
Features
- A single device can perform measurements at high speed undermultiple conditions.(C-D + ESR measurement and L + DCR measurement)
- Optimal measurement conditions can be set automatically accordingto the test sample so switching between setups is a snap.
- DCR temperature compensation (DCR temperature compensationfunction).
- All the measurements necessary to evaluate transformers (such asturn ratio and mutual inductance) in a single device.
- Compact size with a depth of approximately 168 mm (6.61 in)leaves ample room for other equipment.
- Reliable and highly accurate measurements (basic accuracy±0.05% of reading).
- l Frequency sweep function
Hioki IM3533-01 Specifications
Specifications
| Measurement Modes | LCR (Measurement with single condition), Transformer testing (N, M, ΔL), Analyzer (sweep testing), Continuous Testing (LCR/Analyzer mode) |
| Measurement Parameters | Z, Y, Θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), N, M, ΔL, T |
| Measurement Range | 100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.) |
| Displayable Range | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :± (0.00000 [unit] to 9.99999G [unit]) Real value display for Z and Y onlyΘ:± (0.000° to 180.000°)D:± (0.00000 to 9.99999)Q:± (0.00 to 99999.9), Δ%:± (0.0000% to 999.999%)T: -10.0°C to 99.9°C |
| Basic Accuracy | Z :±0.05% rdg.Θ:±0.03° |
| Measurement Frequency | 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz) |
| Measurement Signal Level | [Normal mode] V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms stepsCC mode: 10 μA to 50 mArms, 10 μArms steps[Low impedance high accuracy mode] V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms stepsCC mode: 10 μA to 100 mArms, 10 μArms steps |
| Output Impedance | Normal mode: 100 ΩLow impedance high accuracy mode: 25 Ω |
| Display | 5.7" touch-screen color TFT, display can be set to ON/OFF |
| Measurement Time | 2 ms (1 kHz, FAST, display OFF, representative value) |
| Functions | DC bias measurement, DC resistance temperature compensation (converted reference temperature display), Comparator, BIN measurement (classify function), Panel loading/saving, Memory function |
| Interfaces | EXT I/O (Handler), USB communication (high-speed), USB memoryOptional: Choose 1 from RS-232C, GP-IB, or LAN |
| Power Supply | 100 to 240 V AC, 50/60 Hz, 50 VA max |
| Dimensions | 12.99 x 4.69 x 6.61" (330 x 119 x 168 mm) |
| Weight | 109.3 oz (3.1 kg) |
What's included with the Hioki IM3533-01
- LCR Meter
- Power Cord
- CD-R
- Instruction Manual
Hioki IM3533-01 LCR Meter. Get Free Shipping when you buy now from EquipTestPro.com.