Features
Dedicated Measurement Function
In addition to a normal insulation resistance measurement mode, the IR5051 also features a specialized mode for measuring PV insulation resistance.
Flexible Voltage Range
Effectively measures 1500 V solar PV systems and is prepared to accommodate systems up to 2000 V as technology advances.
Standards Compliance
Complies with IEC 62446-1 for Category 1 and Category 2 tests, ensuring robust safety and performance
Measure insulation resistance while the solar PV system continues to generate
The CAT III 2000 V and CAT IV 1000 V rated IR5051 can measure insulation resistance and open-circuit voltage in solar power systems up to 2000 V safely.
The IR5051 has a PV insulation resistance measurement function. It features the ability to measure even while PV systems are generating power. This means you don’t have to wait until night for measurement or stop power generation.
Identify ground faults in solar power systems using our free app, GENNECT Cross
The CAT III 2000 V and CAT IV 1000 V rated IR5051 can measure insulation resistance and open-circuit voltage in solar power systems up to 2000 V safely.
Intuitive and precise high-voltage insulation testing
Easy-to-use insulation resistance meter with intuitive rotary knob operation.
Precision stability in high voltage insulation testing
When the test object has very high resistance, the insulation resistance meter measures minute currents. Because such measurements are sensitive to even minor changes in the environment, the readings can become unstable. The IR5051 reduces environmental influences using shielded wires, and its unique measurement technology enables stable measurements up to 10 TΩ.
Tailored measurement methods with advanced insulation diagnostic functions
When a high test voltage is continuously applied to the circuit under test, the insulation may break down. Failures caused by the application of a high voltage can be prevented by keeping the applied voltage as low as possible while testing the insulation.
The IR5051 is equipped with various insulation diagnostic functions, allowing you to choose the optimal measurement method according to the testing application.
Automatically calculated and displayed insulation diagnostics
After measurement completes, the instrument can display more than just the insulation resistance and leakage current, but also judgement index values of PI, DD, and DAR. It calculates these indexes based on the measured values and displays it as a pass/fail judgment.
High-Safety design insulation resistance meter
CAT III, CAT IV rated IR5051 hold the highest standards in safety performance. You may think that insulation resistance measurement is not dangerous because it is performed under power outage conditions, but on the contrary, accidents can be dangerous. The IR5051 have enhanced safety performance in case of such an accident.
Start test: Press and hold for 1 sec. to start measurement. This feature helps prevent inadvertent activation of a high voltage.
To encourage caution, the MEASURE button flashes when a high voltage is being generated or discharged.
Complete: The IR5051 will start discharging automatically as soon as the test is over. During this time, the test start button will flash red to indicate that it is discharging.
Wireless support (*1)
Installing the Wireless Adapter Z3210 on the instrument enables Bluetooth® wireless communication, facilitating the transfer of measurements to your smartphone or tablet.
*1: Wireless Adapter Z3210 is necessary.
Enhance your insulation resistance meter with GENNECT Cross
A time-series graph of the current provides a visualization of the insulation state of a high-voltage cable. Utilize the logging function of GENNECT Cross to generate time-series graphs of data recorded at one-second intervals, enhancing the analysis and understanding of trends.
Field Maintenance function: Using a picture of the site, this function can display the measurement values where the measurements are made.
Report function: Easily create PDF reports with measurement results.
Excel® Direct Input Function
Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel®.
Wireless Adapter Z3210 is necessary.
Transfer data via USB after measurement
Transfer measured values and logging data saved on the instrument to a PC via USB (*2). This function requires Sequence Maker, a free Excel add-in.
*2: DMM Communicator DT4900-01 is required (sold separately).
Dustproof & waterproof case for outdoor work
The Carrying Case C0212 is a rigid case with IP65 dust and water protection. It provides space for the insulation resistance meter and test leads so that they can be transported easily.
| Measurement Parameters | Insulation resistancePV insulation resistanceLeakage currentVoltageCapacitance (DD function) |
| Maximum Rated Voltage to Terminals | 1000 V AC, 2000 V DC |
| Maximum Rated Voltage to Ground | 1000 V (CAT IV), 600 V (CAT III) |
| Dustproof/Waterproof | IP40 (with protector attached, excluding terminals)IP65 (Carrying case C0212) |
| Standards | EN61010 (safety), EN61326 (EMC), IEC 61557-1, IEC 61557-2 (Insulation resistance tester) |
| Power Supply | LR6 (AA) alkaline battery × 8HR6 (AA) nickel-metal hydride (NiMH) rechargeable battery × 8 |
| Continuous Operating Time (*) | Approximately 5 hours without Z3210 installed; approx. 4 hours with Z3210 installed and using wireless communication*: When using alkaline batteries, 5 kV generated, +/- terminals open, backlight off and comparator off |
| Dimensions | 7.68 x 10 x 3.50" (195 x 254 x 89 mm) |
| Weight | 59.97 oz. (1.7 kg), including batteries |
Shop EquipTestPro.com for the best deals on Hioki IR5051-90 PV High-Voltage Insulation Tester with wireless adapter, 2000 V. Fast shipping, competitive pricing, and expert support. Visit EquipTestPro.com today!
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.