Hioki PW8001-01 High Precision Power Analyzer, DC, 0.1 Hz to 5 MHz, 3-phase 4-wire is available at EquipTestPro.com with fast shipping and great prices.
Availability: 2 to 3 Weeks
Hioki PW8001-01 High Precision Power Analyzer, DC, 0.1 Hz to 5 MHz, 3-phase 4-wire is available at EquipTestPro.com with fast shipping and great prices.
Upcoming industry challenges are anticipated with the ability to measure even large currents at voltages up to 1500 V, 15 MS/s sampling rate and multi-channel measurement target applications using SiC/GaN semiconductors from automobile electrification, smart grids and reactors to renewable energy supply sources.
Features
*1: When using the 15MS/S Input Unit U7005
*2: When used with a current sensor with automatic phase correction functionality
*3: When using the 2.5MS/S Input Unit U7001
*4: JCSS is standard that is satisfy the requirements of the ISO/IEC 17025 international standard.
Unleashing innovation: Discover version 2.0 with groundbreaking features!
Discover the enhanced Version 2.0 firmware, now with Power Spectrum Analysis (PSA) to accurately analyze high-frequency power loss. Additionally, this latest firmware update brings thoughtful innovations such as improved optical links, IEC harmonics, and flicker management. Explore the refined features of Version 2.0 that blend performance with precision.
Providing the ultimate power analyzer for use by all engineers pursuing power conversion efficiency
Evaluating power conversion efficiency requires the ability to accurately measure power in every band, from DC to high frequencies. The PW8001 delivers exceptional measurement accuracy not only for 50/60 Hz, but also across a broad frequency band, including for DC and at 50 kHz. This allows it to accurately evaluate power conversion efficiency which often involves measuring multiple frequencies.
Accurate capture of power fluctuations caused by high-speed switching
Evaluating power conversion efficiency requires the ability to accurately measure power in every band, from DC to high frequencies. The PW8001 delivers exceptional measurement accuracy not only for 50/60 Hz, but also across a broad frequency band, including for DC and at 50 kHz. This allows it to accurately evaluate power conversion efficiency which often involves measuring multiple frequencies.
Unlocking efficiency in inverter systems: Introducing Power Spectrum Analysis (PSA)
The Power Spectrum Analysis (PSA) function, enhanced by a powerful FFT (Fast Fourier Transform) feature, revolutionizes our approach to analyzing high-frequency power loss. This advanced FFT capability allows for in-depth analysis of voltage, current, and active power, providing detailed insights into power conversion dynamics. This is crucial for enhancing inverter efficiency and minimizing waste in power systems through targeted frequency analysis. The PSA function can provide a clearer picture of electrical issues and helping to pinpoint and reduce power losses more effectively.
Up to 8 power channels optimizing your measurement
Increasingly, hardware like electric vehicle (EV) drive systems that use dual inverters and electric power interchange systems in smart homes are adopting multi-circuit designs in order to utilize energy effectively. A single PW8001 can measure 8 channels of power data, allowing equipment with 8 measurement points for power such as dual motors as well as other equipment with multiple circuits to be evaluated in one stroke.
Seamlessly integrate power analysis: Dual units, single Control for up to 16 channels
By connecting two PW8001 units with an optical cable, measured data can be consolidated in a single PW8001 in real time. The power of a maximum of 16 channels and 8 motors can be simultaneously analyzed and their efficiency and loss can be displayed and recorded with a single unit.
BNC synchronization
Electrical angle measurement function:
For applications requiring up to 32 channels, time-synchronized measurement of 4 PW8001s can be done with BNC cables. (1 is the primary unit, and the 3 others are secondary.) Settings of each unit can be operated on the primary unit. Although the data is saved in each unit, they are time-synchronized for later analysis. Since the measurement-timing is synchronized, this function makes consolidation and analysis easy.
Use cases
Simultaneous measurement of multiple parallel inverters
Issues
Aircraft, ships, and other applications that demand a large amount of drive power sometimes distribute power using multiple inverters that are connected in parallel. When evaluating such systems as a whole, engineers sometimes wish to evaluate power of multiple inverters at the same time. However, if measurements are made separately using multiple power analyzers, the timings of measurement are not aligned making it difficult to combine the data later.
Safe evaluation of increasingly high-voltage power conditioners
Renewable energy generation systems are being engineered to use increasingly high voltages in order to reduce equipment construction costs and transmission loss. Evaluating generation systems requires instruments that are capable of high-voltage measurement. The PW8001 Input Unit U7001 can safely measure directly input high voltages of up to 1500 V DC (CAT II) and 1000 V DC (CAT III). (The Voltage Cord L1025, which can accommodate 1500 V DC [CAT II] and 1000 V DC [CAT III], is also available.)
Analysis of power loss in reactors
In order to improve power conversion efficiency, it’s necessary to assess power loss in reactors. The lower the reactor’s loss, the lower the power factor, making accurate measurement difficult. The U7005’s outstanding high-frequency characteristics and noise resistance make it an extremely effective tool for analyzing power loss in high-frequency, low-power-factor reactors.
Easy installation even in complicated wiring or narrow/tight spaces
The AC/DC Current Probe CT6830 and CT6831 (optional) have a compact and small-size design, making it easy to install in tight spaces around circuit boards, such as the switching power supplies inside products. Furthermore, they cover a wide operating temperature range from -40°C to 85°C, allowing for accurate measurement of low-level DC currents even in environments where the ambient temperature varies.
| Measurement lines | 1-phase-2-wire, 1-phase-3-wire, 3-phase-3-wire, 3-phase-4-wire |
| No. of PW8001 input units | Max. 8 units (mix and match) |
| Type of input unit | U7001 2.5 MS/s INPUT UNITU7005 15 MS/s INPUT UNIT |
| Measurement frequency band | U7001: DC, 0.1 Hz to 1 MHzU7005: DC, 0.1 Hz to 5 MHz |
| Sampling | U7001: 2.5 MHz, 16-bitU7005: 15 MHz, 18-bit |
| Data update rate | 1 ms, 10 ms, 50 ms, 200 ms |
| Accuracy for power (U7001) | 50/60 Hz: 0.02% of reading + 0.05% of rangeDC: 0.02% of reading + 0.05% of range50 kHz : 0.4% of reading + 0.1% of range |
| Accuracy for power (U7005) | 50/60 Hz : 0.01% of reading + 0.02% of rangeDC : 0.02% + 0.03% of reading of range50 kHz: 0.15% of reading + 0.05% of range |
| Measurement range | Voltage: 6 V, 15 V, 30 V, 60 V, 150 V, 300 V, 600 V, 1500 VCurrent: (Probe1) 40 mA to 2 kA, (Probe2) 100 mA to 50 kA(Probe1 : Hioki's high-accuracy current sensor interface supports automatic identification and phase shift correction.Probe 2: BNC I/F only for U7001) |
| Measurement parameters | Voltage (U), current (I), active power (P), apparent power (S), reactive power(Q), power factor (λ), phase angle (φ), voltage frequency (fU), current frequency (fI), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)Harmonics measurement: (Wideband mode: Maximum analysis order 500th, IEC measurement mode)Waveform recording: recording capacity 5M words x ( [voltage/current] ) x - No. of channels + motor waveforms)Motor analysis (option): voltage, torque, RPM, frequency, slip, motor powerFFT analysis (Power spectrum analysis)Flicker measurement |
| IEC measurement mode | When the measurement line has a frequency of 50 Hz or 60 Hz, the instrument can perform harmonic measurements according to IEC61000-4-7 and voltage fluctuation/flicker measurements according to IEC61000-4-15 |
| IEC-compliant harmonic measurement | Compliant with IEC 61000-4-7:2002Analysis order: Harmonics: 0th to 200th orders, Inter-harmonic: 0.5th to 200.5th orders |
| IEC-compliant flicker measurement | Compliant with IEC 61000-4-15:2010 Ed 2.0 Flickermeter Class F2Measurement items: Short-term flicker (Pst), Maximum short-term flicker value (PstMax), Long-term flicker value (Plt), Maximum instantaneous flicker value (PinstMax), Minimum instantaneous flicker value (PinstMin), Relative steady-state voltage change (dc), Maximum relative voltage change (dmax), Period while the relative voltage change exceeds the threshold (Tmax) |
| Calculation function | Efficiency and loss calculations, User-defined calculations, Delta conversion, Current sensor automatic phase shift calculation |
| Synchronization measurement | Optical link: Up to two units, 16 channels maximumBNC Synchronization: Up to four units, 32 channels maximum |
| External interface | USB flash drive, LAN, GP-IB, RS-232C, external control, optical link, BNC sync., CAN or CAN FD |
| Power supply | 100 V to 240 V AC, 50/60 Hz, 230 VA |
| Dimensions and mass | Approx. 430 mm (16.93 in) W × 221 mm (8.70 in) H × 361mm (14.21 in) D, Approx. 14kg (493.84 oz) |
Shop EquipTestPro.com for the best deals on Hioki PW8001-01 High Precision Power Analyzer, DC, 0.1 Hz to 5 MHz, 3-phase 4-wire. Fast shipping, competitive pricing, and expert support. Visit EquipTestPro.com today!
Shop EquipTestPro.com for the best deals on Hioki PW8001-01 High Precision Power Analyzer, DC, 0.1 Hz to 5 MHz, 3-phase 4-wire. Fast shipping, competitive pricing, and expert support. Visit EquipTestPro.com today!
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.