Honeywell BW Clip Series Single-Gas Detector, O2, 0 to 25% volume, two-year

$190.09

BW BWC2-X s

Features

  • Maintenance-free: no sensor or battery changes necessary
  • Compact, lightweight design with one-button operation
  • Designed for a range of harsh environments and extreme temperatures
  • Hibernation mode with case accessory or IntelliDoX
  • Automated self-test of battery, sensor and electronics
  • Wide-angle flash, which alerts simultaneously with audible and vibrating alarm
  • Automatic logging of the 35 most recent gas events and bump test results
  • Compatible with MicroDock II and Fleet Manager II software
  • Affordable, with low cost of ownership

User-friendly, reliable and cost-effective safety tools for compliance and productivity

This single-gas detector is designed to be your everyday companion in hazardous environments. It operates for up to three years with zero maintenance. Once the detector is turned on it'll run continuously, meaning no need for calibration, sensor replacement, battery replacement or even battery charging. Meaning reliable performance with little downtime. This latest version of Fleet Manager II, v.4.3, is recommended for the support of the IntelliDoX for compatible GasAlertMicroClip detectors. All of the same configurable features possible on the MicroDock II have been adapted for the IntelliDoX. Now, users can incorporate their instrument management with the newest addition of IntelliDoX modules. Companies can now be more productive while enhancing their worksite safety management with the easy to network and configure GasAlertMicroClip IntelliDoX.

The Clip is compatible with both the MicroDock II and IntelliDoX instrument management systems.

Ensuring safety, compliance and productivity through advanced technology

  • Surecell™ - Dual reservoir sensor design dramatically improves instrument performance, response time, and longevity compared to traditional electrochemical sensors and consistently delivers reliable instrument performance under the harshest environmental conditions.
  • Reflex Technology™ - Advanced, automated self-test function routinely checks the operating condition of the sensor to increase safety, up-time and overall worker confidence.

BW BWC2-X Specifications

Sensor Specifications
Gas O2
Measuring Range 0 to 25.0% by volume
Alarm Level Low: 19.5%
High: 23.5%
General Specifications
Temperature -4 to 122°F (-20 to 50°C)
Humidity 5 to 95% RH (non-condensing)
Alarms Visual, vibrating, audible (95 dB) - Low, High
Tests Activated detectors automatically perform one internal diagnostic test every 24 hours
Typical Battery Life 2 years
Event Logging 35 most recent events
Ingress Protection IP66/67
Certifications and approvals Class I, Div. 1, Gr. A, B, C, D Class I, Zone 0 , Gr. IIC
ATEX: 0539 II 1G
Ex ia IIC T4 Ga IP66/67
DEMKO 14 ATEX 1356
IECEx: Ex ia IIC T4 Ga IP66/67
IECEx UL 14.0063
European Conformity
Dimensions 1.6 x 2.0 x 3.4" (4.1 x 5.0 x 8.7 cm)
Weight 3.2 oz (92 g)

What's included with the BW BWC2-X

  • Single Gas Detector
  • Stainless Steel Alligator Clip
  • Concussion-Proof Housing
  • Test Cap
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns