Megger BM5200 Insulation Resistance Tester, 5 kV
SKU: 1001-289
Availability: 1 to 2 Weeks2 to 3 Weeks Megger BM5200 Offers This battery powered insulation resistance tester is designed high voltage testing for the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial installations. Automatic discharge for capacitive circuits under test is provided and decaying voltage is displayed. The BM5200 is powered by eight AA batteries and three insulation resistance (IR) test mo
Availability: 1 to 2 Weeks2 to 3 Weeks
Megger BM5200 Offers
This battery powered insulation resistance tester is designed high voltage testing for the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial installations. Automatic discharge for capacitive circuits under test is provided and decaying voltage is displayed. The BM5200 is powered by eight AA batteries and three insulation resistance (IR) test modes are provided.
Features
- 1 TΩ, 1.4 mA, 5 kV Compact, rugged insulation tester with digital and analogue display
- Five test ranges; 250 V, 500 V, 1000 V, 2500 V and 5000 V
- Insulation (InS), Polarisation Index (PI) and variable timed test (t) modes
- Guard terminal to shunt surface leakage currents
- Selectable DC or AC (incl. frequency) voltmeter functions
- High voltage warning indicator
- External voltage display after IR test
- Automatic discharge of reactive loads and test leads
- CATIII 600 V safety rating
Applications
- Product test and qualification
- Installation of equipment
- Routine maintenance
- Problem resolutions
Megger BM5200 Specifications
| Insulation range | 100 kΩ to 1 TΩ |
| Nominal test voltages | 250 V, 500 V, 1000 V, 2500 V, 5000 V |
| Terminal voltage accuracy | < 1000 V 0...+10% of nominal test voltage ≥1000 V 0...+5% of nominal test voltage |
| Insulation accuracy | Up to 1 GΩ: All ranges ±5% ±2 digits Over 1 GΩ: 5000 V ±5% ±0.04% per GΩ 2500 V ±5% ±0.08% per GΩ 1000 V ±5% ±0.2% per GΩ 500 V ±5% ±0.4% per GΩ 250 V ±5% ±0.8% per GΩ |
| Short circuit/charge current | 1.4 mA ±0.5 mA |
| Maximum capacitance of load | 5 μF |
| Voltmeter accuracy | 3% ± 3 V |
| Frequency measurement | 45 Hz to 65 Hz |
| Frequency measurement accuracy | ±2 Hz |
| Voltmeter range | Up to 600 V a.c. or d.c. |
| Power supply | 8 x LR6/AA batteries (included) |
| Battery life | 5 lbs (2.3 kg) |
| 5 hours @ 5 kV into 100 MΩ with AA Alkaline LR6 | 5 lbs (2.3 kg) |
| Guard | 2% error guarding 5 MΩ leakage on 100 MΩ load |
| Operating temperature range and humidity | -20 to +55°C |
| Humidity | 90% RH, 0 to 40°C 70% RH, 40 to 55°C |
| Storage temperature range | -20 to +65°C |
| IP rating | IP40 |
| Safety protection | Insulation Cat III 600 V |
| EMC | The product conforms to IEC 61326 |
| Dimensions | 220 mm x 115 mm x 163 mm |
| Weight | 1.45 kg |