Megger DCM1500S Solar Clamp Meter, 2000 V DC, 1500 V AC
SKU: 1013-357
Availability: 1 to 2 Weeks Megger DCM1500S Offers Remotely monitor measurement values on a smart device with this solar clamp meter which features built-in Bluetooth to view a live trend graph and sample and log the values for later analysis. Additionally, this meter features a high-frequency rejection filter, inrush current measurement, internal data logging, a non-contact volt seek mode, and manual DC Amp zeroing. Features 2000 V DC TRMS 150
Availability: 1 to 2 Weeks
Megger DCM1500S Offers
Remotely monitor measurement values on a smart device with this solar clamp meter which features built-in Bluetooth to view a live trend graph and sample and log the values for later analysis. Additionally, this meter features a high-frequency rejection filter, inrush current measurement, internal data logging, a non-contact volt seek mode, and manual DC Amp zeroing.
Features
- 2000 V DC
- TRMS 1500 V AC
- 1500 A AC/DC
- Smart hold
- Auto ranging
- Minimum/Maximum hold
- Inrush current
- Megger Link app compatible
- CAT IV 600 V / CAT III 1000 V
- Data logger
- PV test leads with MC4PV plugs
- 60000 counts digital display
- Large white LED backlit display
- True RMS reading on ACA/ACV
- AC/DC μA Range
- Resistance, diode, capacitance and frequency measurement
- °C/°F temperature function
- DCA zero
- Torch light on trigger push
- Data Logging up to 1000 records
- Manual save mode
- Auto power off
- DC mV Range
Applications
- Solar/photovoltaic installations
- Electrical systems and equipment
- Battery monitoring
- Automotive
- Charging and load circuits
- Electric vehicle servicing
- Lift maintenance
- UPS commissioning, servicing and maintenance
- Electro-plating plants and welding equipment servicing
- Domestic power generation from solar panels and wind-turbines
The unit is designed to be used on electrical systems and equipment, including solar/photovoltaic installations where, there is a need to measure current, volts, resistance and frequency. It is therefore intended for use while installing, maintaining, fault-finding or monitoring those systems. The tactile barrier below the jaws of the instrument ensures a safe working distance for the operator's hand when measuring current on live uninsulated conductors, although additional personal protection must still be used. The Smart Hold allows increases in measurements to be monitored with an audible tone. The Maximum/Minimum and In-rush modes enable maximum load currents from equipment to be identified such as start-up currents to motors and heaters.
Megger DCM1500S Specifications
| DC mV | Range: 600 mV OL reading: 660 mV Resolution: 0.1 mV Accuracy: ±(0.7% + 5D) |
| DC Voltage | Range: 600 mV; 1000 V OL reading: 660 mV; 1100 V Resolution: 0.1 V; 1 V Accuracy: ±(0.7% + 2D) |
| AC Voltage | Range: 600 mV; 1000 V OL reading: 660 mV; 1100 V Resolution: 0.1 V; 1 V Accuracy: ±(1% + 5D) |
| PV DC Voltage (using PVHV1 or PVHV2 lead set) | Range: 600 mV; 2000 V OL reading: 660 mV; 2200 V Resolution: 0.1 V; 1 V Accuracy: (2% + 5D) |
| PV AC Voltage (using PVHV1 or PVHV2 lead set) | Range: 600 mV; 1500 V OL reading: 660 mV; 1600 V Resolution: 0.1 V; 1 V Accuracy: (2% + 5D) |
| AC/DC μA | Range: 400 μA; 4000 μA OL reading: 440 μA; 4400 μA Resolution: 0.1 μA; 1 μA Accuracy: ±(1% + 3D |
| AC/DC Current | Range: 60 A; 600 A; 1500 A OL reading: 66 A; 660 A; 1550 A Resolution: 0.01 A; 0.1 A; 1 A Accuracy: ±(2% + 5D) |
| Frequency | Range: 100 Hz; 1000 Hz; 10 kHz OL reading: 100 Hz; 1000 Hz; 10 kHz Resolution: 0.01 Hz; 0.1 Hz; 0.001 kHz Accuracy: ±(0.3% + 3D) |
| Resistance | Range: 600 Ω; 6 kΩ; 60 kΩ; 600 kΩ OL reading: 660 Ω; 6.6 kΩ; 66 kΩ; 660 kΩ Resolution: 0.1 Ω; 0.001 kΩ; 0.01 kΩ; 0.1 kΩ Accuracy: ±(0.9% + 5D); ±(0.9% + 2D) |
| Continuity | Built-in buzzer sounds when measured resistance is less than 20 Ω and the sound is off when measured resistance is more than 200 Ω, between 20 to 200 Ω the buzzer may be either on or off |
| Diode | Range: 1.5 V OL reading: 1.55 V Resolution: 0.001 V Accuracy: ±(0.9% + 2D) |
| Capacitance | Range: 100 μF; 1000 μF OL reading: 110 μF; 1100 μF Resolution: 0.1 μF; 1 μF Accuracy: ±(1.9% + 2D) |
| VoltSeek | Voltage range of high sensitivity: 80 to 1000 V (at the top edge of the jaw) Voltage range of low sensitivity: 160 to 1000 V (at the top edge of the jaw) |
| Temperature | Range: -40 to 752°F (-40 to 400°C) OL reading: 824°F (440°C) Resolution: 0.1°F (0.1°C) Accuracy: ±1% + 36D (±1% + 20D) The accuracy does not include the accuracy of the thermocouple probe. Accuracy specification assumes surrounding temperature stable to ±1°C. For surrounding temperature changes of ±2°C rated accuracy applies after 2 hours |
Click here for complete specifications on the Megger DCM1500S