Megger DET4TC2 4-Terminal Digital Ground Resistance Tester with ICLAMP and VCLAMP, 2/3/4 point testing
SKU: DET4TC2+Clamps
Availability: 2 to 3 Weeks Megger DET4TC2+Clamps Offers Designed to negate the need for a shorting link when making two-pole measurements, this ground tester also offers labeled auxiliary controls used to select the test frequency (94, 105, 111, and 128 Hz), output voltage (50 or 25 V where local standards apply), and to switch the backlight on or off. Features Stakeless testing capability – Allows the operator to use the instrument like a cla
Availability: 2 to 3 Weeks
Megger DET4TC2+Clamps Offers
Designed to negate the need for a shorting link when making two-pole measurements, this ground tester also offers labeled auxiliary controls used to select the test frequency (94, 105, 111, and 128 Hz), output voltage (50 or 25 V where local standards apply), and to switch the backlight on or off.
Features
- Stakeless testing capability - Allows the operator to use the instrument like a clamp-on tester in applications where the method is viable
- Attached Rod Technique capability - Allows fall of potential testing without the need to disconnect the ground rod
- Multiple user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
- 200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil
- User selectable test voltage ensures that the units can be used in agricultural environments
- Microprocessor control for improved error detection
- Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
- Rugged, weatherproof case to IP54
- Backlit LCD allows for testing in dark environments
- Noise rejection to 40 V pk to pk allows accurate testing in noisy environments
- Accuracy of 2% of reading enhances reliability of measurements
- Voltmeter function allows you to measure the ground voltage and enhances operator safety
- CAT IV 100V provides increased operator safety
Applications
- Primary and secondary electrical grounding systems
- Utility pole grounds
- Lightning protection systems
- Residential grounds
- Machinery safety grounds
- Computer and communication system grounds
- EMI/RFI system grounds
- Antenna and pedestal grounds
- CATV system grounds
Megger DET4TC2+Clamps Specifications
Specifications
| Resistance Range | 0.01 Ω to 20 kΩ |
| Resistance Accuracy | 2p Measurements: 2% ±3 digits3p Measurements: 2% ±3 digits4p Measurements: 2% ±3 digitsART Measurements: 5% ±3 digitsStakeless Measurements: 7% ±3 digits |
| Maximum Probe Resistance | Rp limit: 200 kΩ (50 V output voltage)Rc limit: 200 kΩ (50 V output voltage)Limits reduced to 100 kΩ for 25 V output voltageLimits reduced to 5 kΩ for 0.01 Ω resolution |
| Earth Voltage | Range: 0 to 100 V ACAccuracy: 2% ±2 V |
| C Spike Check | Automatic |
| P Spike Check | Automatic |
| Noise | Check: AutomaticRejection: 40 V pk to pk |
| Test | Frequency: 94, 105, 111 and 128 HzVoltage: 25 or 50 V, user selectable (factory setting 50 V)Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V |
| Display | 3½" digit high contrast LCD, backlit |
| Battery | Type: 8 x 1.5 V AA cellsLife: 3 hours, 700 consecutive tests |
| Temperature Range | Operating: 5 to 131°F (-15 to 55°C)Storage: -40 to 158°F (-40 to 70°C) |
| Humidity | 95% RH non-condensing at 104°F (40°C) |
| Safety | EN61010-1 CAT IV 100 V |
| Ingress Protection | IP54 |
| Dimensions | 8 x 5.7 x 3.2" (203 x 148 x 78 mm) |
| Weight | 2.20 lbs (1 kg) |
What's included with the Megger DET4TC2+Clamps
- Ground Resistance Tester
- Certificate of Calibration
- 1000 A AC Current Probe
- Voltage Clamp for Stakeless Method
- 4 x Test Leads (49', 33', 33', 10')
- 4 x Spikes
- Hard Carrying Case
- 8 x 1.5 V AA Cells Batteries
- 2-Year Warranty
Megger DET4TC2 4-Terminal Digital Ground Resistance Tester with ICLAMP and VCLAMP, 2/3/4 point testing. Get Free Shipping when you order today on EquipTestPro.com.
Related Products