Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester is available at EquipTestPro.com with fast shipping and great prices.
Features
Stakeless (Clamp-on) Testing

The DET4TC and DET4TCR2 include stakeless, or clamp-on testing capability. In effect, these models can be operated in the same way as a clamp-on ground under test and drive test probes un certain ground system testing applications. this method is also useful when there us insufficient space to perform a classic fall-of-potential measurement. In addition the units can be used to measure ground leakage or phase current.
the user simply clamps the optional ICLAMP and VCLAMP around the ground under the test in the manner prescribed in the operator's manual and takes the reading. A defined test voltage is injected into the system using the VCLAMP, including a current, I, to flow and be measured by the ICLAMP. The instrument then calculates the approximate resistance of the ground under test.
The stakeless method is subject tot the same limitations faced by the traditional clamp-on ground tester. It is effective only in situations where multiple grounds in parallel and cannot be proofed like a fall-of-potential test. In situations where the stakeless method reading is questionable, a full fall-of potential test is recommended. The advantage of the DET4TC2 and DET4TCR2 is that the units include both test methods in a single instrument, making them the worst versatile units available.

Applications
Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of a computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.
The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitivity equipment and heat build-up on a single piece of electrical equipment.
The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an AC signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.
Grounding electrodes from simple to complex systems can be tested, including:
| Resistance range | 0.01Ω to 200kΩ auto ranging |
| Analog model | 2.5% of scale length |
| Digital models | 2P measurements 2% ±3 digits, 3P measurements 2% ±3 digits, 4P measurements 2% ±3 digits, ART measurements 5% ±3 digits, Stakeless measurements 7% ±3 digits |
| Maximum probe resistance | Rp limit: 100k½ (50V output voltage), Rc limit: 100k½ (50V output voltage), Limits reduced to 50k½ for 25V output voltage, Limits reduced to 5k½ for 0.01 ½ resolution |
| Earth voltage range | 0-100V |
| Earth voltage accuracy | 2% ±2 V |
| 2-wire test | Yes, all models |
| 3-wire test | yes, all models |
| 4-wire test | DET4TD, DET4TC2, DET4TCR2 |
| Ground current range (with current measuring clamp) | 0.5mA to 19.9A |
| Ground current accuracy | 5% ±3 digits |
| Display | LCD (moving coil meter for analog model) |
| Test frequency | 128 Hz |
| Test voltage | 25 V or 50 V, user selectable (factory setting 50 V) |
| Test current | 450 micro-amps at 25 V or 50 V (selectable), 4.5mA at 25 V |
| Noise rejection | 40V pk to pk |
| Battery type | 8 1.5 V AA cells |
| Battery life | 3 hours, 700 consecutive tests |
| Safety | EN61010-1 CAT IV 100 V |
| Dimensions | 8 x 5.7 x 3.2 in. (203 x 148 x 78 mm) |
| Weight | 2.2 lb (1 kg) |
Shop EquipTestPro.com for the best deals on Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester. Fast shipping, competitive pricing, and expert support. Visit equiptestpro.com today!
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.